Reference record for OID 1.3.6.1.4.1.232.0.13603423

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13603423
Node names
  • sCellEventTrap_d_5f
  • sCellEventTrap-0d-5f
Numeric OID
1.3.6.1.4.1.232.0.13603423
URN notation
urn:oid:1.3.6.1.4.1.232.0.13603423
ASN.1 notation

{1 3 6 1 4 1 232 0 13603423}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13603423
  • /ISO/Identified-Organization/6/1/4/1/232/0/13603423
  • /ISO/3/6/1/4/1/232/0/13603423
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-0d-5f
  • Additional combinations skipped.

Descriptions

sCellEventTrap-0d-5f — MIBdepot

Severity: Critical -- failure or failure imminent. The temperature of Enclosure Link Module temperature sensor is at a critical level. The operational power supply(s) will automatically shut down the drive bays after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values.

sCellEventTrap_d_5f — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. <P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

sCellEventTrap-0d-5f — HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C.

sCellEventTrap-0d-5f — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values.

Source records

sCellEventTrap-0d-5f

Status in source: unspecified.

Names: sCellEventTrap-0d-5f

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5f",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The temperature of Enclosure Link Module temperature sensor is at a critical level. The operational power supply(s) will automatically shut down the drive bays after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values.\"",
    "::=",
    "13603423"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The temperature of Enclosure Link Module temperature sensor is at a critical level. The operational power supply(s) will automatically shut down the drive bays after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of Enclosure Link Module temperature sensor is at a critical level. The operational power supply(s) will automatically shut down the drive bays after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

sCellEventTrap_d_5f

Status in source: unspecified.

Names: sCellEventTrap_d_5f

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_d_5f",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. <P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13603423"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. <P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. <P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_5f.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. <P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-0d-5f

Status in source: unspecified.

Names: sCellEventTrap-0d-5f

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5f",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C.\"",
    "::=",
    "13603423"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB
    Source location: CPQHSV340V11-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5f8706"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB
    Source location: CPQHSV300V11-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5f8706"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB
    Source location: CPQHSV360V11-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5f8706"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB
    Source location: CPQHSV450V11-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5f8706"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB
    Source location: CPQHSV400V11-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

sCellEventTrap-0d-5f

Status in source: unspecified.

Names: sCellEventTrap-0d-5f

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5f",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values.\"",
    "::=",
    "13603423"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
               --#TYPE      "StorageCell Event 0d5f8711"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB
    Source location: CPQHSV200V6-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.136000008 mngmtAgentTrap_8, mngmtAgentTrap-800
1.3.6.1.4.1.232.0.136000009 mngmtAgentTrap_9, mngmtAgentTrap-900
1.3.6.1.4.1.232.0.136000010 mngmtAgentTrap_10, mngmtAgentTrap-1000
1.3.6.1.4.1.232.0.136000011 mngmtAgentTrap_11, mngmtAgentTrap-1100
1.3.6.1.4.1.232.0.136000012 mngmtAgentTrap_12, mngmtAgentTrap-1200
1.3.6.1.4.1.232.0.136000013 mngmtAgentTrap_13, mngmtAgentTrap-1300
1.3.6.1.4.1.232.0.136000014 mngmtAgentTrap_14, mngmtAgentTrap-1400
1.3.6.1.4.1.232.0.136000015 mngmtAgentTrap_15, mngmtAgentTrap-1500
1.3.6.1.4.1.232.0.136000016 mngmtAgentTrap_16, mngmtAgentTrap-1600
1.3.6.1.4.1.232.0.136000017 mngmtAgentTrap_17, mngmtAgentTrap-1700
1.3.6.1.4.1.232.0.136000018 mngmtAgentTrap_18, mngmtAgentTrap-1800
1.3.6.1.4.1.232.0.136000019 mngmtAgentTrap_19, mngmtAgentTrap-1900
1.3.6.1.4.1.232.0.136000020 mngmtAgentTrap_20, mngmtAgentTrap-2000
1.3.6.1.4.1.232.0.136000021 mngmtAgentTrap_21, mngmtAgentTrap-2100
1.3.6.1.4.1.232.0.136000022 mngmtAgentTrap_22, mngmtAgentTrap-2200
1.3.6.1.4.1.232.0.136000023 mngmtAgentTrap_23, mngmtAgentTrap-2300
1.3.6.1.4.1.232.0.136000024 mngmtAgentTrap_24, mngmtAgentTrap-2400
1.3.6.1.4.1.232.0.136000025 mngmtAgentTrap_25, mngmtAgentTrap-2500
1.3.6.1.4.1.232.0.136000026 mngmtAgentTrap_26, mngmtAgentTrap-2600
1.3.6.1.4.1.232.0.136000027 mngmtAgentTrap_27, mngmtAgentTrap-2700
1.3.6.1.4.1.232.0.136000028 mngmtAgentTrap_28, mngmtAgentTrap-2800
1.3.6.1.4.1.232.0.136000029 mngmtAgentTrap_29, mngmtAgentTrap-2900
1.3.6.1.4.1.232.0.136000030 mngmtAgentTrap_30, mngmtAgentTrap-3000
1.3.6.1.4.1.232.0.136000031 mngmtAgentTrap_31, mngmtAgentTrap-3100
1.3.6.1.4.1.232.0.136000032 mngmtAgentTrap_32, mngmtAgentTrap-3200
1.3.6.1.4.1.232.0.136000033 mngmtAgentTrap_33, mngmtAgentTrap-3300
1.3.6.1.4.1.232.0.136000034 mngmtAgentTrap_34, mngmtAgentTrap-3400
1.3.6.1.4.1.232.0.136000035 mngmtAgentTrap_35, mngmtAgentTrap-3500
1.3.6.1.4.1.232.0.136000036 mngmtAgentTrap_36, mngmtAgentTrap-3600
1.3.6.1.4.1.232.0.136000037 mngmtAgentTrap_37, mngmtAgentTrap-3700
1.3.6.1.4.1.232.0.136000038 mngmtAgentTrap_38, mngmtAgentTrap-3800
1.3.6.1.4.1.232.0.136000039 mngmtAgentTrap_39, mngmtAgentTrap-3900
1.3.6.1.4.1.232.0.136000040 mngmtAgentTrap_40, mngmtAgentTrap-4000
1.3.6.1.4.1.232.0.136000041 mngmtAgentTrap_41, mngmtAgentTrap-4100
1.3.6.1.4.1.232.0.136000042 mngmtAgentTrap_42, mngmtAgentTrap-4200
1.3.6.1.4.1.232.0.136000043 mngmtAgentTrap_43, mngmtAgentTrap-4300
1.3.6.1.4.1.232.0.136000044 mngmtAgentTrap_44, mngmtAgentTrap-4400
1.3.6.1.4.1.232.0.136000045 mngmtAgentTrap_45, mngmtAgentTrap-4500
1.3.6.1.4.1.232.0.136000046 mngmtAgentTrap_46, mngmtAgentTrap-4600
1.3.6.1.4.1.232.0.136000047 mngmtAgentTrap_47, mngmtAgentTrap-4700
1.3.6.1.4.1.232.0.136000048 mngmtAgentTrap_48, mngmtAgentTrap-4800
1.3.6.1.4.1.232.0.136000049 mngmtAgentTrap_49, mngmtAgentTrap-4900
1.3.6.1.4.1.232.0.136000050 mngmtAgentTrap_50, mngmtAgentTrap-5000
1.3.6.1.4.1.232.0.136000051 mngmtAgentTrap_51, mngmtAgentTrap-5100
1.3.6.1.4.1.232.0.136000052 mngmtAgentTrap_52, mngmtAgentTrap-5200
1.3.6.1.4.1.232.0.136000053 mngmtAgentTrap_53, mngmtAgentTrap-5300
1.3.6.1.4.1.232.0.136000054 mngmtAgentTrap_54, mngmtAgentTrap-5400
1.3.6.1.4.1.232.0.136000055 mngmtAgentTrap_55, mngmtAgentTrap-5500
1.3.6.1.4.1.232.0.136000056 mngmtAgentTrap_56, mngmtAgentTrap-5600
1.3.6.1.4.1.232.0.136000057 mngmtAgentTrap_57, mngmtAgentTrap-5700