Reference record for OID 1.3.6.1.4.1.232.0.13603439

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13603439
Node names
  • sCellEventTrap_d_6f
  • sCellEventTrap-0d-6f
Numeric OID
1.3.6.1.4.1.232.0.13603439
URN notation
urn:oid:1.3.6.1.4.1.232.0.13603439
ASN.1 notation

{1 3 6 1 4 1 232 0 13603439}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-6f(13603439)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-6f(13603439)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13603439
  • /ISO/Identified-Organization/6/1/4/1/232/0/13603439
  • /ISO/3/6/1/4/1/232/0/13603439
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_d_6f
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-0d-6f
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_d_6f
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-0d-6f
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_d_6f
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-0d-6f
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_d_6f
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-0d-6f
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_d_6f
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-0d-6f
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_d_6f
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-0d-6f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_d_6f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-0d-6f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_d_6f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-0d-6f
  • Additional combinations skipped.

Descriptions

sCellEventTrap_d_6f — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = An internal Drive Enclosure Environmental Monitoring Unit clock error has occurred. <LI>2 = The Inter-IC (I2C) bus is not processing data and the Drive Enclosure Environmental Monitoring Unit is unable to monitor or report the status of the elements or enclosures. <LI>5 = A Backplane NVRAM error has occurred. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

sCellEventTrap-0d-6f — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred.

Source records

sCellEventTrap_d_6f

Status in source: unspecified.

Names: sCellEventTrap_d_6f

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_d_6f",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = An internal Drive Enclosure Environmental Monitoring Unit clock error has occurred. <LI>2 = The Inter-IC (I2C) bus is not processing data and the Drive Enclosure Environmental Monitoring Unit is unable to monitor or report the status of the elements or enclosures. <LI>5 = A Backplane NVRAM error has occurred. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13603439"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = An internal Drive Enclosure Environmental Monitoring Unit clock error has occurred. <LI>2 = The Inter-IC (I2C) bus is not processing data and the Drive Enclosure Environmental Monitoring Unit is unable to monitor or report the status of the elements or enclosures. <LI>5 = A Backplane NVRAM error has occurred. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_6f TRAP-TYPE  -- CAC Code: 88
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = An internal Drive Enclosure Environmental Monitoring Unit clock error has occurred. <LI>2 = The Inter-IC (I2C) bus is not processing data and the Drive Enclosure Environmental Monitoring Unit is unable to monitor or report the status of the elements or enclosures. <LI>5 = A Backplane NVRAM error has occurred. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603439
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_6f.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_6f TRAP-TYPE  -- CAC Code: 88
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = An internal Drive Enclosure Environmental Monitoring Unit clock error has occurred. <LI>2 = The Inter-IC (I2C) bus is not processing data and the Drive Enclosure Environmental Monitoring Unit is unable to monitor or report the status of the elements or enclosures. <LI>5 = A Backplane NVRAM error has occurred. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603439
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_6f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-0d-6f

Status in source: unspecified.

Names: sCellEventTrap-0d-6f

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-6f",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred.\"",
    "::=",
    "13603439"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-6f TRAP-TYPE  -- CAC Code: 88
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603439
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-0d-6f.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-0d-6f TRAP-TYPE  -- CAC Code: 88
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred."
               --#TYPE      "StorageCell Event 0d6f8811"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603439
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB
    Source location: CPQHSV200V6-MIB::sCellEventTrap-0d-6f.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-6f TRAP-TYPE  -- CAC Code: 88
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603439
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-0d-6f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.6031 cpqHe3FltTolPowerSupplyFailed00
1.3.6.1.4.1.232.0.6032 cpqHe3FltTolPowerRedundancyLost00
1.3.6.1.4.1.232.0.6033 cpqHe3FltTolPowerSupplyInserted00
1.3.6.1.4.1.232.0.6034 cpqHe3FltTolPowerSupplyRemoved00
1.3.6.1.4.1.232.0.6035 cpqHe3FltTolFanDegraded00
1.3.6.1.4.1.232.0.6036 cpqHe3FltTolFanFailed00
1.3.6.1.4.1.232.0.6037 cpqHe3FltTolFanRedundancyLost00
1.3.6.1.4.1.232.0.6038 cpqHe3FltTolFanInserted00
1.3.6.1.4.1.232.0.6039 cpqHe3FltTolFanRemoved00
1.3.6.1.4.1.232.0.6040 cpqHe3TemperatureFailed00
1.3.6.1.4.1.232.0.6041 cpqHe3TemperatureDegraded00
1.3.6.1.4.1.232.0.6042 cpqHe3TemperatureOk00
1.3.6.1.4.1.232.0.6043 cpqHe3PowerConverterDegraded00
1.3.6.1.4.1.232.0.6044 cpqHe3PowerConverterFailed00
1.3.6.1.4.1.232.0.6045 cpqHe3PowerConverterRedundancyLost00
1.3.6.1.4.1.232.0.6046 cpqHe3CacheAccelParityError00
1.3.6.1.4.1.232.0.6047 cpqHeResilientMemOnlineSpareEngaged00
1.3.6.1.4.1.232.0.6048 cpqHe4FltTolPowerSupplyOk00
1.3.6.1.4.1.232.0.6049 cpqHe4FltTolPowerSupplyDegraded00
1.3.6.1.4.1.232.0.6050 cpqHe4FltTolPowerSupplyFailed00
1.3.6.1.4.1.232.0.6051 cpqHeResilientMemMirroredMemoryEngaged00
1.3.6.1.4.1.232.0.6052 cpqHeResilientAdvancedECCMemoryEngaged00
1.3.6.1.4.1.232.0.6053 cpqHeResilientMemXorMemoryEngaged00
1.3.6.1.4.1.232.0.6054 cpqHe3FltTolPowerRedundancyRestored00
1.3.6.1.4.1.232.0.6055 cpqHe3FltTolFanRedundancyRestored00
1.3.6.1.4.1.232.0.6056 cpqHe4CorrMemReplaceMemModule00
1.3.6.1.4.1.232.0.6057 cpqHeResMemBoardRemoved00
1.3.6.1.4.1.232.0.6058 cpqHeResMemBoardInserted00
1.3.6.1.4.1.232.0.6059 cpqHeResMemBoardBusError00
1.3.6.1.4.1.232.0.6060 cpqHeEventOccurred00
1.3.6.1.4.1.232.0.6061 cpqHeManagementProcInReset00
1.3.6.1.4.1.232.0.6062 cpqHeManagementProcReady00
1.3.6.1.4.1.232.0.6063 cpqHeManagementProcFailedReset00
1.3.6.1.4.1.232.0.6064 cpqHe5CorrMemReplaceMemModule00
1.3.6.1.4.1.232.0.6065 cpqHe5ResMemBoardRemoved00
1.3.6.1.4.1.232.0.6066 cpqHe5ResMemBoardInserted00
1.3.6.1.4.1.232.0.6067 cpqHe5ResMemBoardBusError00
1.3.6.1.4.1.232.0.6068 cpqHeResilientMemLockStepMemoryEngaged00
1.3.6.1.4.1.232.0.6069 cpqHe4FltTolPowerSupplyACpowerloss00
1.3.6.1.4.1.232.0.6070 cpqHeSysBatteryFailed00
1.3.6.1.4.1.232.0.6071 cpqHeSysBatteryRemoved00
1.3.6.1.4.1.232.0.6072 cpqHeSysPwrAllocationNotOptimized00
1.3.6.1.4.1.232.0.6073 cpqHeSysPwrOnDenied00
1.3.6.1.4.1.232.0.6074 cpqHePowerFailureError00
1.3.6.1.4.1.232.0.6075 cpqHeInterlockFailureError00
1.3.6.1.4.1.232.0.6076 cpqHeNvdimmBackupError00
1.3.6.1.4.1.232.0.6077 cpqHeNvdimmRestoreError00
1.3.6.1.4.1.232.0.6078 cpqHeNvdimmUncorrectableMemoryError00
1.3.6.1.4.1.232.0.6079 cpqHeNvdimmBackupPowerError00
1.3.6.1.4.1.232.0.6080 cpqHeNvdimmNVDIMMControllerError00