Reference record for OID 1.3.6.1.4.1.232.0.13603469

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13603469
Node names
  • sCellEventTrap_d_8d
  • sCellEventTrap-0d-8d
Numeric OID
1.3.6.1.4.1.232.0.13603469
URN notation
urn:oid:1.3.6.1.4.1.232.0.13603469
ASN.1 notation

{1 3 6 1 4 1 232 0 13603469}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-8d(13603469)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-8d(13603469)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13603469
  • /ISO/Identified-Organization/6/1/4/1/232/0/13603469
  • /ISO/3/6/1/4/1/232/0/13603469
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_d_8d
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-0d-8d
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_d_8d
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-0d-8d
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_d_8d
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-0d-8d
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_d_8d
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-0d-8d
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_d_8d
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-0d-8d
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_d_8d
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-0d-8d
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_d_8d
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-0d-8d
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_d_8d
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-0d-8d
  • Additional combinations skipped.

Descriptions

sCellEventTrap-0d-8d — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected.

sCellEventTrap_d_8d — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the transceiver (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Transceiver 01 <LI>2 = Transceiver 02 <LI>3 = Transceiver 03 <LI>4 = Transceiver 04 </UL><P> The transceiver error condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The transceivers on this link are not the same type or they are incompatible with the drive enclosure I/O module. This error prevents the controller from establishing a link with the enclosure drives and eliminates the enclosure dual-loop capability. <LI>2 = The transceiver can no longer detect a data signal. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>3 = The system has detected an FC-AL bus fault involving a transceiver. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>4 = The transceiver that was previously in this location has been removed. <LI>5 = The transceiver in the specified location has detected invalid Fibre Channel characters. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

Source records

sCellEventTrap-0d-8d

Status in source: unspecified.

Names: sCellEventTrap-0d-8d

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-8d",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected.\"",
    "::=",
    "13603469"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-8d TRAP-TYPE  -- CAC Code: 90
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603469
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-0d-8d.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-0d-8d TRAP-TYPE  -- CAC Code: 90
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603469
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-0d-8d.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-0d-8d TRAP-TYPE  -- CAC Code: 90
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected."
               --#TYPE      "StorageCell Event 0d8d9011"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603469
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-0d-8d.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-0d-8d TRAP-TYPE  -- CAC Code: 90
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603469
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB
    Source location: CPQHSV340V11-MIB::sCellEventTrap-0d-8d.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-0d-8d TRAP-TYPE  -- CAC Code: 90
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected."
               --#TYPE      "StorageCell Event 0d8d9006"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603469
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB
    Source location: CPQHSV300V11-MIB::sCellEventTrap-0d-8d.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-8d TRAP-TYPE  -- CAC Code: 90
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603469
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-0d-8d.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-0d-8d TRAP-TYPE  -- CAC Code: 90
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected."
               --#TYPE      "StorageCell Event 0d8d9006"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603469
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB
    Source location: CPQHSV360V11-MIB::sCellEventTrap-0d-8d.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-0d-8d TRAP-TYPE  -- CAC Code: 90
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected."
               --#TYPE      "StorageCell Event 0d8d9006"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603469
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB
    Source location: CPQHSV450V11-MIB::sCellEventTrap-0d-8d.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-0d-8d TRAP-TYPE  -- CAC Code: 90
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected."
               --#TYPE      "StorageCell Event 0d8d9006"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603469
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB
    Source location: CPQHSV400V11-MIB::sCellEventTrap-0d-8d.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

sCellEventTrap_d_8d

Status in source: unspecified.

Names: sCellEventTrap_d_8d

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_d_8d",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the transceiver (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Transceiver 01 <LI>2 = Transceiver 02 <LI>3 = Transceiver 03 <LI>4 = Transceiver 04 </UL><P> The transceiver error condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The transceivers on this link are not the same type or they are incompatible with the drive enclosure I/O module. This error prevents the controller from establishing a link with the enclosure drives and eliminates the enclosure dual-loop capability. <LI>2 = The transceiver can no longer detect a data signal. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>3 = The system has detected an FC-AL bus fault involving a transceiver. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>4 = The transceiver that was previously in this location has been removed. <LI>5 = The transceiver in the specified location has detected invalid Fibre Channel characters. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13603469"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the transceiver (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Transceiver 01 <LI>2 = Transceiver 02 <LI>3 = Transceiver 03 <LI>4 = Transceiver 04 </UL><P> The transceiver error condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The transceivers on this link are not the same type or they are incompatible with the drive enclosure I/O module. This error prevents the controller from establishing a link with the enclosure drives and eliminates the enclosure dual-loop capability. <LI>2 = The transceiver can no longer detect a data signal. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>3 = The system has detected an FC-AL bus fault involving a transceiver. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>4 = The transceiver that was previously in this location has been removed. <LI>5 = The transceiver in the specified location has detected invalid Fibre Channel characters. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_8d TRAP-TYPE  -- CAC Code: 90
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the transceiver (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Transceiver 01 <LI>2 = Transceiver 02 <LI>3 = Transceiver 03 <LI>4 = Transceiver 04 </UL><P> The transceiver error condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The transceivers on this link are not the same type or they are incompatible with the drive enclosure I/O module. This error prevents the controller from establishing a link with the enclosure drives and eliminates the enclosure dual-loop capability. <LI>2 = The transceiver can no longer detect a data signal. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>3 = The system has detected an FC-AL bus fault involving a transceiver. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>4 = The transceiver that was previously in this location has been removed. <LI>5 = The transceiver in the specified location has detected invalid Fibre Channel characters. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603469
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_8d.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_8d TRAP-TYPE  -- CAC Code: 90
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the transceiver (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Transceiver 01 <LI>2 = Transceiver 02 <LI>3 = Transceiver 03 <LI>4 = Transceiver 04 </UL><P> The transceiver error condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The transceivers on this link are not the same type or they are incompatible with the drive enclosure I/O module. This error prevents the controller from establishing a link with the enclosure drives and eliminates the enclosure dual-loop capability. <LI>2 = The transceiver can no longer detect a data signal. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>3 = The system has detected an FC-AL bus fault involving a transceiver. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>4 = The transceiver that was previously in this location has been removed. <LI>5 = The transceiver in the specified location has detected invalid Fibre Channel characters. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603469
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_8d.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.136027007 mngmtAgentTrap_27007, mngmtAgentTrap-2700700
1.3.6.1.4.1.232.0.136027008 mngmtAgentTrap_27008, mngmtAgentTrap-2700800
1.3.6.1.4.1.232.0.136027009 mngmtAgentTrap_27009, mngmtAgentTrap-2700900
1.3.6.1.4.1.232.0.136027010 mngmtAgentTrap_27010, mngmtAgentTrap-2701000
1.3.6.1.4.1.232.0.136027011 mngmtAgentTrap_27011, mngmtAgentTrap-2701100
1.3.6.1.4.1.232.0.136027012 mngmtAgentTrap_27012, mngmtAgentTrap-2701200
1.3.6.1.4.1.232.0.136027013 mngmtAgentTrap_27013, mngmtAgentTrap-2701300
1.3.6.1.4.1.232.0.136027014 mngmtAgentTrap_27014, mngmtAgentTrap-2701400
1.3.6.1.4.1.232.0.136027015 mngmtAgentTrap_27015, mngmtAgentTrap-2701500
1.3.6.1.4.1.232.0.136027016 mngmtAgentTrap_27016, mngmtAgentTrap-2701600
1.3.6.1.4.1.232.0.136027017 mngmtAgentTrap_27017, mngmtAgentTrap-2701700
1.3.6.1.4.1.232.0.136027018 mngmtAgentTrap_27018, mngmtAgentTrap-2701800
1.3.6.1.4.1.232.0.136027019 mngmtAgentTrap_27019, mngmtAgentTrap-2701900
1.3.6.1.4.1.232.0.136027020 mngmtAgentTrap_27020, mngmtAgentTrap-2702000
1.3.6.1.4.1.232.0.136027021 mngmtAgentTrap_27021, mngmtAgentTrap-2702100
1.3.6.1.4.1.232.0.136027022 mngmtAgentTrap_27022, mngmtAgentTrap-2702200
1.3.6.1.4.1.232.0.136027023 mngmtAgentTrap_27023, mngmtAgentTrap-2702300
1.3.6.1.4.1.232.0.136027024 mngmtAgentTrap_27024, mngmtAgentTrap-2702400
1.3.6.1.4.1.232.0.136027025 mngmtAgentTrap_27025, mngmtAgentTrap-2702500
1.3.6.1.4.1.232.0.136027026 mngmtAgentTrap_27026, mngmtAgentTrap-2702600
1.3.6.1.4.1.232.0.136027027 mngmtAgentTrap_27027, mngmtAgentTrap-2702700
1.3.6.1.4.1.232.0.136027028 mngmtAgentTrap_27028, mngmtAgentTrap-2702800
1.3.6.1.4.1.232.0.136027029 mngmtAgentTrap_27029, mngmtAgentTrap-2702900
1.3.6.1.4.1.232.0.136027030 mngmtAgentTrap_27030, mngmtAgentTrap-2703000
1.3.6.1.4.1.232.0.136027031 mngmtAgentTrap_27031, mngmtAgentTrap-2703100
1.3.6.1.4.1.232.0.136027032 mngmtAgentTrap_27032, mngmtAgentTrap-2703200
1.3.6.1.4.1.232.0.136027033 mngmtAgentTrap_27033, mngmtAgentTrap-2703300
1.3.6.1.4.1.232.0.136027034 mngmtAgentTrap_27034, mngmtAgentTrap-2703400
1.3.6.1.4.1.232.0.136027035 mngmtAgentTrap_27035, mngmtAgentTrap-2703500
1.3.6.1.4.1.232.0.136027036 mngmtAgentTrap_27036, mngmtAgentTrap-2703600
1.3.6.1.4.1.232.0.136027037 mngmtAgentTrap_27037, mngmtAgentTrap-2703700
1.3.6.1.4.1.232.0.136027038 mngmtAgentTrap_27038, mngmtAgentTrap-2703800
1.3.6.1.4.1.232.0.136027039 mngmtAgentTrap_27039, mngmtAgentTrap-2703900
1.3.6.1.4.1.232.0.136027040 mngmtAgentTrap_27040, mngmtAgentTrap-2704000
1.3.6.1.4.1.232.0.136027041 mngmtAgentTrap_27041, mngmtAgentTrap-2704100
1.3.6.1.4.1.232.0.136027042 mngmtAgentTrap_27042, mngmtAgentTrap-2704200
1.3.6.1.4.1.232.0.136027043 mngmtAgentTrap_27043, mngmtAgentTrap-2704300
1.3.6.1.4.1.232.0.136027044 mngmtAgentTrap_27044, mngmtAgentTrap-2704400
1.3.6.1.4.1.232.0.136027045 mngmtAgentTrap_27045, mngmtAgentTrap-2704500
1.3.6.1.4.1.232.0.136027046 mngmtAgentTrap_27046, mngmtAgentTrap-2704600
1.3.6.1.4.1.232.0.136027047 mngmtAgentTrap_27047, mngmtAgentTrap-2704700
1.3.6.1.4.1.232.0.136027048 mngmtAgentTrap_27048, mngmtAgentTrap-2704800
1.3.6.1.4.1.232.0.136027049 mngmtAgentTrap_27049, mngmtAgentTrap-2704900
1.3.6.1.4.1.232.0.136027050 mngmtAgentTrap-2705000
1.3.6.1.4.1.232.0.136027051 mngmtAgentTrap-2705100
1.3.6.1.4.1.232.0.136027052 mngmtAgentTrap-2705200
1.3.6.1.4.1.232.0.136027053 mngmtAgentTrap-2705300
1.3.6.1.4.1.232.0.136027054 mngmtAgentTrap-2705400
1.3.6.1.4.1.232.0.136027055 mngmtAgentTrap-2705500
1.3.6.1.4.1.232.0.136027056 mngmtAgentTrap-2705600