Reference record for OID 1.3.6.1.4.1.232.0.13603489

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13603489
Node names
  • sCellEventTrap_d_a1
  • sCellEventTrap-0d-a1
Numeric OID
1.3.6.1.4.1.232.0.13603489
URN notation
urn:oid:1.3.6.1.4.1.232.0.13603489
ASN.1 notation

{1 3 6 1 4 1 232 0 13603489}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13603489
  • /ISO/Identified-Organization/6/1/4/1/232/0/13603489
  • /ISO/3/6/1/4/1/232/0/13603489
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-0d-a1
  • Additional combinations skipped.

Descriptions

sCellEventTrap_d_a1 — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element voltage is above the high voltage CRITICAL threshold. <LI>3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>4 = The element voltage has reached the low voltage CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

sCellEventTrap-0d-a1 — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported.

Source records

sCellEventTrap_d_a1

Status in source: unspecified.

Names: sCellEventTrap_d_a1

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_d_a1",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element voltage is above the high voltage CRITICAL threshold. <LI>3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>4 = The element voltage has reached the low voltage CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13603489"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element voltage is above the high voltage CRITICAL threshold. <LI>3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>4 = The element voltage has reached the low voltage CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_a1 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element voltage is above the high voltage CRITICAL threshold. <LI>3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>4 = The element voltage has reached the low voltage CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603489
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_a1.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_a1 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element voltage is above the high voltage CRITICAL threshold. <LI>3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>4 = The element voltage has reached the low voltage CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603489
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_a1.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-0d-a1

Status in source: unspecified.

Names: sCellEventTrap-0d-a1

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-a1",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported.\"",
    "::=",
    "13603489"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-a1 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603489
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-0d-a1.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-0d-a1 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported."
               --#TYPE      "StorageCell Event 0da18111"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603489
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB
    Source location: CPQHSV200V6-MIB::sCellEventTrap-0d-a1.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-a1 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603489
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-0d-a1.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.3006 cpqDa2AccelBadDataTrap00
1.3.6.1.4.1.232.0.3007 cpqDa2AccelBatteryFailed00
1.3.6.1.4.1.232.0.3008 cpqDa3LogDrvStatusChange00
1.3.6.1.4.1.232.0.3009 cpqDa3SpareStatusChange00
1.3.6.1.4.1.232.0.3010 cpqDa3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3011 cpqDa3PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3012 cpqDa3AccelStatusChange00
1.3.6.1.4.1.232.0.3013 cpqDa3AccelBadDataTrap00
1.3.6.1.4.1.232.0.3014 cpqDa3AccelBatteryFailed00
1.3.6.1.4.1.232.0.3015 cpqDaCntlrStatusChange00
1.3.6.1.4.1.232.0.3016 cpqDaCntlrActive00
1.3.6.1.4.1.232.0.3017 cpqDa4SpareStatusChange00
1.3.6.1.4.1.232.0.3018 cpqDa4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3019 cpqDa4PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3020 cpqDaTapeLibraryStatusChange00
1.3.6.1.4.1.232.0.3021 cpqDaTapeLibraryDoorStatusChange00
1.3.6.1.4.1.232.0.3022 cpqDaTapeDriveStatusChange00
1.3.6.1.4.1.232.0.3023 cpqDaTapeDriveCleaningRequired00
1.3.6.1.4.1.232.0.3024 cpqDaTapeDriveCleanTapeReplace00
1.3.6.1.4.1.232.0.3025 cpqDa5AccelStatusChange00
1.3.6.1.4.1.232.0.3026 cpqDa5AccelBadDataTrap00
1.3.6.1.4.1.232.0.3027 cpqDa5AccelBatteryFailed00
1.3.6.1.4.1.232.0.3028 cpqDa5CntlrStatusChange00
1.3.6.1.4.1.232.0.3029 cpqDa5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3030 cpqDa5PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3031 cpqDa2TapeLibraryStatusChange00
1.3.6.1.4.1.232.0.3032 cpqDa2TapeDriveStatusChange00
1.3.6.1.4.1.232.0.3033 cpqDa6CntlrStatusChange00
1.3.6.1.4.1.232.0.3034 cpqDa6LogDrvStatusChange00
1.3.6.1.4.1.232.0.3035 cpqDa6SpareStatusChange00
1.3.6.1.4.1.232.0.3036 cpqDa6PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3037 cpqDa6PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3038 cpqDa6AccelStatusChange00
1.3.6.1.4.1.232.0.3039 cpqDa6AccelBadDataTrap00
1.3.6.1.4.1.232.0.3040 cpqDa6AccelBatteryFailed00
1.3.6.1.4.1.232.0.3041 cpqDa6TapeLibraryStatusChange00
1.3.6.1.4.1.232.0.3042 cpqDa6TapeLibraryDoorStatusChange00
1.3.6.1.4.1.232.0.3043 cpqDa6TapeDriveStatusChange00
1.3.6.1.4.1.232.0.3044 cpqDa6TapeDriveCleaningRequired00
1.3.6.1.4.1.232.0.3045 cpqDa6TapeDriveCleanTapeReplace00
1.3.6.1.4.1.232.0.3046 cpqDa7PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3047 cpqDa7SpareStatusChange00
1.3.6.1.4.1.232.0.3048 cpqDaCntlrPartnerStatusChange00
1.3.6.1.4.1.232.0.3049 cpqDaPhyDrvSSDWearStatusChange00
1.3.6.1.4.1.232.0.3903 cpqDaSmartArraySecureEraseFailed00
1.3.6.1.4.1.232.0.5001 cpqScsi2CntlrStatusChange00
1.3.6.1.4.1.232.0.5002 cpqScsi2LogDrvStatusChange00
1.3.6.1.4.1.232.0.5003 cpqScsi2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5004 cpqTapePhyDrvStatusChange00
1.3.6.1.4.1.232.0.5005 cpqScsi3CntlrStatusChange00