Reference record for OID 1.3.6.1.4.1.232.0.13603489

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13603489
Node names
  • sCellEventTrap_d_a1
  • sCellEventTrap-0d-a1
Numeric OID
1.3.6.1.4.1.232.0.13603489
URN notation
urn:oid:1.3.6.1.4.1.232.0.13603489
ASN.1 notation

{1 3 6 1 4 1 232 0 13603489}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-a1(13603489)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-a1(13603489)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13603489
  • /ISO/Identified-Organization/6/1/4/1/232/0/13603489
  • /ISO/3/6/1/4/1/232/0/13603489
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-0d-a1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_d_a1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-0d-a1
  • Additional combinations skipped.

Descriptions

sCellEventTrap_d_a1 — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element voltage is above the high voltage CRITICAL threshold. <LI>3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>4 = The element voltage has reached the low voltage CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

sCellEventTrap-0d-a1 — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported.

Source records

sCellEventTrap_d_a1

Status in source: unspecified.

Names: sCellEventTrap_d_a1

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_d_a1",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element voltage is above the high voltage CRITICAL threshold. <LI>3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>4 = The element voltage has reached the low voltage CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13603489"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element voltage is above the high voltage CRITICAL threshold. <LI>3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>4 = The element voltage has reached the low voltage CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_a1 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element voltage is above the high voltage CRITICAL threshold. <LI>3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>4 = The element voltage has reached the low voltage CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603489
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_a1.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_a1 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element voltage is above the high voltage CRITICAL threshold. <LI>3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>4 = The element voltage has reached the low voltage CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603489
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_a1.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-0d-a1

Status in source: unspecified.

Names: sCellEventTrap-0d-a1

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-a1",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported.\"",
    "::=",
    "13603489"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-a1 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603489
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-0d-a1.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-0d-a1 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported."
               --#TYPE      "StorageCell Event 0da18111"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603489
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB
    Source location: CPQHSV200V6-MIB::sCellEventTrap-0d-a1.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-a1 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out-of-range condition has been reported."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603489
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-0d-a1.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.136004043 mngmtAgentTrap_4043, mngmtAgentTrap-404300
1.3.6.1.4.1.232.0.136004047 mngmtAgentTrap_4047, mngmtAgentTrap-404700
1.3.6.1.4.1.232.0.136004048 mngmtAgentTrap_4048, mngmtAgentTrap-404800
1.3.6.1.4.1.232.0.136004049 mngmtAgentTrap_4049, mngmtAgentTrap-404900
1.3.6.1.4.1.232.0.136004050 mngmtAgentTrap_4050, mngmtAgentTrap-405000
1.3.6.1.4.1.232.0.136004051 mngmtAgentTrap_4051, mngmtAgentTrap-405100
1.3.6.1.4.1.232.0.136004052 mngmtAgentTrap_4052, mngmtAgentTrap-405200
1.3.6.1.4.1.232.0.136004053 mngmtAgentTrap_4053, mngmtAgentTrap-405300
1.3.6.1.4.1.232.0.136004054 mngmtAgentTrap_4054, mngmtAgentTrap-405400
1.3.6.1.4.1.232.0.136004058 mngmtAgentTrap_4058, mngmtAgentTrap-405800
1.3.6.1.4.1.232.0.136004059 mngmtAgentTrap_4059, mngmtAgentTrap-405900
1.3.6.1.4.1.232.0.136004075 mngmtAgentTrap-407500
1.3.6.1.4.1.232.0.136004077 mngmtAgentTrap-407700
1.3.6.1.4.1.232.0.136004078 mngmtAgentTrap-407800
1.3.6.1.4.1.232.0.136004081 mngmtAgentTrap-408100
1.3.6.1.4.1.232.0.136005001 mngmtAgentTrap_5001, mngmtAgentTrap-500100
1.3.6.1.4.1.232.0.136005002 mngmtAgentTrap_5002, mngmtAgentTrap-500200
1.3.6.1.4.1.232.0.136005003 mngmtAgentTrap_5003, mngmtAgentTrap-500300
1.3.6.1.4.1.232.0.136005004 mngmtAgentTrap_5004, mngmtAgentTrap-500400
1.3.6.1.4.1.232.0.136005005 mngmtAgentTrap_5005, mngmtAgentTrap-500500
1.3.6.1.4.1.232.0.136005006 mngmtAgentTrap_5006, mngmtAgentTrap-500600
1.3.6.1.4.1.232.0.136005007 mngmtAgentTrap_5007, mngmtAgentTrap-500700
1.3.6.1.4.1.232.0.136005008 mngmtAgentTrap_5008, mngmtAgentTrap-500800
1.3.6.1.4.1.232.0.136005010 mngmtAgentTrap_5010, mngmtAgentTrap-501000
1.3.6.1.4.1.232.0.136005011 mngmtAgentTrap_5011, mngmtAgentTrap-501100
1.3.6.1.4.1.232.0.136005012 mngmtAgentTrap_5012, mngmtAgentTrap-501200
1.3.6.1.4.1.232.0.136005013 mngmtAgentTrap_5013, mngmtAgentTrap-501300
1.3.6.1.4.1.232.0.136005014 mngmtAgentTrap_5014, mngmtAgentTrap-501400
1.3.6.1.4.1.232.0.136005015 mngmtAgentTrap_5015, mngmtAgentTrap-501500
1.3.6.1.4.1.232.0.136005016 mngmtAgentTrap_5016, mngmtAgentTrap-501600
1.3.6.1.4.1.232.0.136005017 mngmtAgentTrap_5017, mngmtAgentTrap-501700
1.3.6.1.4.1.232.0.136005018 mngmtAgentTrap_5018, mngmtAgentTrap-501800
1.3.6.1.4.1.232.0.136005019 mngmtAgentTrap_5019, mngmtAgentTrap-501900
1.3.6.1.4.1.232.0.136006001 mngmtAgentTrap_6001, mngmtAgentTrap-600100
1.3.6.1.4.1.232.0.136006002 mngmtAgentTrap_6002, mngmtAgentTrap-600200
1.3.6.1.4.1.232.0.136006003 mngmtAgentTrap_6003, mngmtAgentTrap-600300
1.3.6.1.4.1.232.0.136006004 mngmtAgentTrap_6004, mngmtAgentTrap-600400
1.3.6.1.4.1.232.0.136006005 mngmtAgentTrap_6005, mngmtAgentTrap-600500
1.3.6.1.4.1.232.0.136006006 mngmtAgentTrap_6006, mngmtAgentTrap-600600
1.3.6.1.4.1.232.0.136006007 mngmtAgentTrap_6007, mngmtAgentTrap-600700
1.3.6.1.4.1.232.0.136006008 mngmtAgentTrap_6008, mngmtAgentTrap-600800
1.3.6.1.4.1.232.0.136006009 mngmtAgentTrap_6009, mngmtAgentTrap-600900
1.3.6.1.4.1.232.0.136006010 mngmtAgentTrap_6010, mngmtAgentTrap-601000
1.3.6.1.4.1.232.0.136006011 mngmtAgentTrap_6011, mngmtAgentTrap-601100
1.3.6.1.4.1.232.0.136006012 mngmtAgentTrap_6012, mngmtAgentTrap-601200
1.3.6.1.4.1.232.0.136006013 mngmtAgentTrap_6013, mngmtAgentTrap-601300
1.3.6.1.4.1.232.0.136006014 mngmtAgentTrap_6014, mngmtAgentTrap-601400
1.3.6.1.4.1.232.0.136006015 mngmtAgentTrap_6015, mngmtAgentTrap-601500
1.3.6.1.4.1.232.0.136006016 mngmtAgentTrap_6016, mngmtAgentTrap-601600
1.3.6.1.4.1.232.0.136006017 mngmtAgentTrap_6017, mngmtAgentTrap-601700