Reference record for OID 1.3.6.1.4.1.232.0.13603509

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13603509
Node names
  • sCellEventTrap_d_b5
  • sCellEventTrap-0d-b5
Numeric OID
1.3.6.1.4.1.232.0.13603509
URN notation
urn:oid:1.3.6.1.4.1.232.0.13603509
ASN.1 notation

{1 3 6 1 4 1 232 0 13603509}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13603509
  • /ISO/Identified-Organization/6/1/4/1/232/0/13603509
  • /ISO/3/6/1/4/1/232/0/13603509
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-0d-b5
  • Additional combinations skipped.

Descriptions

sCellEventTrap-0d-b5 — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported.

sCellEventTrap_d_b5 — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element current is above the high current CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

Source records

sCellEventTrap-0d-b5

Status in source: unspecified.

Names: sCellEventTrap-0d-b5

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-b5",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported.\"",
    "::=",
    "13603509"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-b5 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603509
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-0d-b5.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-0d-b5 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported."
               --#TYPE      "StorageCell Event 0db58111"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603509
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-0d-b5.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-b5 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603509
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB

    Related source files and packages:


    Source location: CPQHSV-MIB::sCellEventTrap-0d-b5.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

sCellEventTrap_d_b5

Status in source: unspecified.

Names: sCellEventTrap_d_b5

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_d_b5",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element current is above the high current CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13603509"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element current is above the high current CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_b5 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element current is above the high current CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603509
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_b5.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_b5 TRAP-TYPE  -- CAC Code: 81
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element current is above the high current CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603509
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_b5.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.13603620 sCellEventTrap-0e-2400
1.3.6.1.4.1.232.0.13603621 sCellEventTrap-0e-2500
1.3.6.1.4.1.232.0.13603622 sCellEventTrap-0e-2600
1.3.6.1.4.1.232.0.13603623 sCellEventTrap-0e-2700
1.3.6.1.4.1.232.0.13603624 sCellEventTrap-0e-2800
1.3.6.1.4.1.232.0.13603625 sCellEventTrap-0e-2900
1.3.6.1.4.1.232.0.13603626 sCellEventTrap-0e-2a00
1.3.6.1.4.1.232.0.13603627 sCellEventTrap-0e-2b00
1.3.6.1.4.1.232.0.13603628 sCellEventTrap-0e-2c00
1.3.6.1.4.1.232.0.13603629 sCellEventTrap-0e-2d00
1.3.6.1.4.1.232.0.13603630 sCellEventTrap-0e-2e00
1.3.6.1.4.1.232.0.13603631 sCellEventTrap-0e-2f00
1.3.6.1.4.1.232.0.13603636 sCellEventTrap-0e-3400
1.3.6.1.4.1.232.0.13603637 sCellEventTrap-0e-3500
1.3.6.1.4.1.232.0.13603638 sCellEventTrap-0e-3600
1.3.6.1.4.1.232.0.13603639 sCellEventTrap-0e-3700
1.3.6.1.4.1.232.0.13603640 sCellEventTrap-0e-3800
1.3.6.1.4.1.232.0.13603641 sCellEventTrap-0e-3900
1.3.6.1.4.1.232.0.13603642 sCellEventTrap-0e-3a00
1.3.6.1.4.1.232.0.13603643 sCellEventTrap-0e-3b00
1.3.6.1.4.1.232.0.13603644 sCellEventTrap-0e-3c00
1.3.6.1.4.1.232.0.13603645 sCellEventTrap-0e-3d00
1.3.6.1.4.1.232.0.13603646 sCellEventTrap-0e-3e00
1.3.6.1.4.1.232.0.13603647 sCellEventTrap-0e-3f00
1.3.6.1.4.1.232.0.13603648 sCellEventTrap-0e-4000
1.3.6.1.4.1.232.0.13603649 sCellEventTrap-0e-4100
1.3.6.1.4.1.232.0.13603650 sCellEventTrap-0e-4200
1.3.6.1.4.1.232.0.13603651 sCellEventTrap-0e-4300
1.3.6.1.4.1.232.0.13603652 sCellEventTrap-0e-4400
1.3.6.1.4.1.232.0.13603653 sCellEventTrap-0e-4500
1.3.6.1.4.1.232.0.13603654 sCellEventTrap-0e-4600
1.3.6.1.4.1.232.0.13603655 sCellEventTrap-0e-4700
1.3.6.1.4.1.232.0.13603656 sCellEventTrap-0e-4800
1.3.6.1.4.1.232.0.13603657 sCellEventTrap-0e-4900
1.3.6.1.4.1.232.0.13603658 sCellEventTrap-0e-4a00
1.3.6.1.4.1.232.0.13603659 sCellEventTrap-0e-4b00
1.3.6.1.4.1.232.0.13603660 sCellEventTrap-0e-4c00
1.3.6.1.4.1.232.0.13603661 sCellEventTrap-0e-4d00
1.3.6.1.4.1.232.0.13603662 sCellEventTrap-0e-4e00
1.3.6.1.4.1.232.0.13603663 sCellEventTrap-0e-4f00
1.3.6.1.4.1.232.0.13603664 sCellEventTrap-0e-5000
1.3.6.1.4.1.232.0.13603665 sCellEventTrap-0e-5100
1.3.6.1.4.1.232.0.13603666 sCellEventTrap-0e-5200
1.3.6.1.4.1.232.0.13603667 sCellEventTrap-0e-5300
1.3.6.1.4.1.232.0.13603668 sCellEventTrap-0e-5400
1.3.6.1.4.1.232.0.13603669 sCellEventTrap-0e-5500
1.3.6.1.4.1.232.0.13603670 sCellEventTrap-0e-5600
1.3.6.1.4.1.232.0.13603671 sCellEventTrap-0e-5700
1.3.6.1.4.1.232.0.13603712 sCellEventTrap-0e-8000
1.3.6.1.4.1.232.0.13603713 sCellEventTrap-0e-8100