cpqIdeAtaDiskStatusChange
Numeric OID
1.3.6.1.4.1.232.0.14004
URN notation
urn:oid:1.3.6.1.4.1.232.0.14004
ASN.1 notation

{1 3 6 1 4 1 232 0 14004}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/14004
  • /ISO/Identified-Organization/6/1/4/1/232/0/14004
  • /ISO/3/6/1/4/1/232/0/14004
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqIdeAtaDiskStatusChange
  • Additional combinations skipped.

Descriptions

cpqIdeAtaDiskStatusChange — HPE networking MIB copies (LibreNMS/Observium Community)

ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, `failed(4)` or `ssdWearOut(5)` replace the drive.

cpqIdeAtaDiskStatusChange — Circitor, MIBdepot

ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive.

Source records

cpqIdeAtaDiskStatusChange

Status in source: unspecified.

Names: cpqIdeAtaDiskStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqIdeAtaDiskStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqIdeAtaDiskControllerIndex",
    ",",
    "cpqIdeAtaDiskIndex",
    ",",
    "cpqIdeAtaDiskModel",
    ",",
    "cpqIdeAtaDiskFwRev",
    ",",
    "cpqIdeAtaDiskSerialNumber",
    ",",
    "cpqIdeAtaDiskStatus",
    ",",
    "cpqIdeAtaDiskChannel",
    ",",
    "cpqIdeAtaDiskNumber",
    "}",
    "DESCRIPTION",
    "\"ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, `failed(4)` or `ssdWearOut(5)` replace the drive.\"",
    "::=",
    "14004"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqIdeAtaDiskControllerIndex",
        "cpqIdeAtaDiskIndex",
        "cpqIdeAtaDiskModel",
        "cpqIdeAtaDiskFwRev",
        "cpqIdeAtaDiskSerialNumber",
        "cpqIdeAtaDiskStatus",
        "cpqIdeAtaDiskChannel",
        "cpqIdeAtaDiskNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, `failed(4)` or `ssdWearOut(5)` replace the drive."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, 
                 `failed(4)` or `ssdWearOut(5)` replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change (14004)"
            --#SUMMARY "ATA disk drive status is now %d for drive %d."
            --#ARGUMENTS {7, 9}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY STORAGE
            --#ACTION "If the disk drive status is 'smartError(3)', 'failed(4)' or 'ssdWearOut(5)', replace the drive."
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE-MIB

    Related source files and packages:


    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.176278+00:00.

cpqIdeAtaDiskStatusChange

Status in source: unspecified.

Names: cpqIdeAtaDiskStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqIdeAtaDiskStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqIdeAtaDiskControllerIndex",
    ",",
    "cpqIdeAtaDiskIndex",
    ",",
    "cpqIdeAtaDiskModel",
    ",",
    "cpqIdeAtaDiskFwRev",
    ",",
    "cpqIdeAtaDiskSerialNumber",
    ",",
    "cpqIdeAtaDiskStatus",
    ",",
    "cpqIdeAtaDiskChannel",
    ",",
    "cpqIdeAtaDiskNumber",
    "}",
    "DESCRIPTION",
    "\"ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive.\"",
    "::=",
    "14004"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqIdeAtaDiskControllerIndex",
        "cpqIdeAtaDiskIndex",
        "cpqIdeAtaDiskModel",
        "cpqIdeAtaDiskFwRev",
        "cpqIdeAtaDiskSerialNumber",
        "cpqIdeAtaDiskStatus",
        "cpqIdeAtaDiskChannel",
        "cpqIdeAtaDiskNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If the physical drive status is smartError(3) or
                 failed(4), replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change (14004)"
            --#SUMMARY "Status is now %d for the ATA disk."
            --#ARGUMENTS {7}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE.MIB.txt
    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.784225+00:00.

  • Preserved mibdepot archive

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If the physical drive status is smartError(3) or
                 failed(4), replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change"
            --#SUMMARY "Status is now %d for the ATA disk."
            --#ARGUMENTS {7}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE1.MIB.txt
    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.784568+00:00.

  • Preserved circitor archive

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If the physical drive status is smartError(3) or
                 failed(4), replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change (14004)"
            --#SUMMARY "Status is now %d for the ATA disk."
            --#ARGUMENTS {7}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE-MIB.mib
    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:16.780674+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.22030 cpqRackPowerChassisNotLoadBalanced00
1.3.6.1.4.1.232.0.22031 cpqRackPowerChassisDcPowerProblem00
1.3.6.1.4.1.232.0.22032 cpqRackPowerChassisAcFacilityPowerExceeded00
1.3.6.1.4.1.232.0.22033 cpqRackPowerUnknownPowerConsumption00
1.3.6.1.4.1.232.0.22034 cpqRackPowerChassisLoadBalancingWireMissing00
1.3.6.1.4.1.232.0.22035 cpqRackPowerChassisTooManyPowerChassis00
1.3.6.1.4.1.232.0.22036 cpqRackPowerChassisConfigError00
1.3.6.1.4.1.232.0.22037 cpqRackEnclosureManagerDegraded00
1.3.6.1.4.1.232.0.22038 cpqRackEnclosureManagerOk00
1.3.6.1.4.1.232.0.22039 cpqRackEnclosureManagerRemoved00
1.3.6.1.4.1.232.0.22040 cpqRackEnclosureManagerInserted00
1.3.6.1.4.1.232.0.22041 cpqRackManagerPrimaryRole00
1.3.6.1.4.1.232.0.22042 cpqRackServerBladeEKeyingFailed00
1.3.6.1.4.1.232.0.22043 cpqRackServerBladeEKeyingOK00
1.3.6.1.4.1.232.0.22044 cpqRackNetConnectorRemoved00
1.3.6.1.4.1.232.0.22045 cpqRackNetConnectorInserted00
1.3.6.1.4.1.232.0.22046 cpqRackNetConnectorFailed00
1.3.6.1.4.1.232.0.22047 cpqRackNetConnectorDegraded00
1.3.6.1.4.1.232.0.22048 cpqRackNetConnectorOk00
1.3.6.1.4.1.232.0.22049 cpqRackServerBladeToLowPower00
1.3.6.1.4.1.232.0.22050 cpqRackServerBladeRemoved200
1.3.6.1.4.1.232.0.22051 cpqRackServerBladeInserted200
1.3.6.1.4.1.232.0.22052 cpqRackServerBladeStatusRepaired00
1.3.6.1.4.1.232.0.22053 cpqRackServerBladeStatusDegraded00
1.3.6.1.4.1.232.0.22054 cpqRackServerBladeStatusCritical00
1.3.6.1.4.1.232.0.22055 cpqRackServerBladeGrpCapTimeout00
1.3.6.1.4.1.232.0.22056 cpqRackServerBladeUnexpectedShutdown00
1.3.6.1.4.1.232.0.22057 cpqRackServerBladeMangementControllerFirmwareUpdating00
1.3.6.1.4.1.232.0.22058 cpqRackServerBladeMangementControllerFirmwareUpdateComplete00
1.3.6.1.4.1.232.0.22059 cpqRackServerBladeSystemBIOSFirmwareUpdating00
1.3.6.1.4.1.232.0.22060 cpqRackServerBladeSystemBIOSFirmwareUpdateCompleted00
1.3.6.1.4.1.232.0.22061 cpqRackServerBladeFrontIOBlankingActive00
1.3.6.1.4.1.232.0.22062 cpqRackServerBladeRemoteFrontIOBlankingInactive00
1.3.6.1.4.1.232.0.22063 cpqRackServerBladeDiagnosticAdaptorInserted00
1.3.6.1.4.1.232.0.22064 cpqRackServerBladeDiagnosticAdaptorRemoved00
1.3.6.1.4.1.232.0.22065 cpqRackServerBladeEnteredPXEBootMode00
1.3.6.1.4.1.232.0.22066 cpqRackServerBladeExitedPXEBootMode00
1.3.6.1.4.1.232.0.22067 cpqRackServerBladeWarmReset00
1.3.6.1.4.1.232.0.22068 cpqRackServerBladePOSTCompleted00
1.3.6.1.4.1.232.0.22069 cpqRackServerBladePoweredOn00
1.3.6.1.4.1.232.0.22070 cpqRackServerBladePoweredOff00
1.3.6.1.4.1.232.0.22071 cpqRackInformationalEAETrap00
1.3.6.1.4.1.232.0.22072 cpqRackMinorEAETrap00
1.3.6.1.4.1.232.0.22073 cpqRackMajorEAETrap00
1.3.6.1.4.1.232.0.22074 cpqRackCriticalEAETrap00
1.3.6.1.4.1.232.0.22075 cpqRackPowerMinorEAETrap00
1.3.6.1.4.1.232.0.22076 cpqRackPowerMajorEAETrap00
1.3.6.1.4.1.232.0.22077 cpqRackPowerCriticalEAETrap00
1.3.6.1.4.1.232.0.22078 cpqRackServerBladePartitionChange00
1.3.6.1.4.1.232.0.22079 cpqRackInformationalWSMANTrap00