Reference record for OID 1.3.6.1.4.1.232.0.16005

Parent
1.3.6.1.4.1.232.0 (0)
Node code
16005
Node name
cpqFcaAccelBadDataTrap
Numeric OID
1.3.6.1.4.1.232.0.16005
URN notation
urn:oid:1.3.6.1.4.1.232.0.16005
ASN.1 notation

{1 3 6 1 4 1 232 0 16005}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqFcaAccelBadDataTrap(16005)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/16005
  • /ISO/Identified-Organization/6/1/4/1/232/0/16005
  • /ISO/3/6/1/4/1/232/0/16005
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqFcaAccelBadDataTrap
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqFcaAccelBadDataTrap
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqFcaAccelBadDataTrap
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqFcaAccelBadDataTrap
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqFcaAccelBadDataTrap
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqFcaAccelBadDataTrap
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqFcaAccelBadDataTrap
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqFcaAccelBadDataTrap
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqFcaAccelBadDataTrap
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqFcaAccelBadDataTrap
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqFcaAccelBadDataTrap
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqFcaAccelBadDataTrap
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqFcaAccelBadDataTrap
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqFcaAccelBadDataTrap
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqFcaAccelBadDataTrap
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqFcaAccelBadDataTrap
  • Additional combinations skipped.

Descriptions

cpqFcaAccelBadDataTrap — MIBdepot

Accelerator Board Bad Data. This trap signifies that the Insight Agent has detected a Compaq Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the server lost power, that data has been lost. User Action: Verify that no data has been lost.

cpqFcaAccelBadDataTrap — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

External Array Accelerator Board Bad Data. This trap signifies that the agent has detected a Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the system lost power, that data has been lost. User Action: Verify that no data has been lost.

cpqFcaAccelBadDataTrap — MIBdepot

Fibre Channel Array Accelerator Board Bad Data. This trap signifies that the agent has detected a Compaq Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the system lost power, that data has been lost. User Action: Verify that no data has been lost.

Source records

cpqFcaAccelBadDataTrap

Status in source: unspecified.

Names: cpqFcaAccelBadDataTrap

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqFcaAccelBadDataTrap",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSsChassisName",
    ",",
    "cpqSsChassisTime",
    ",",
    "cpqFcaAccelBoxIoSlot",
    "}",
    "DESCRIPTION",
    "\"Accelerator Board Bad Data. This trap signifies that the Insight Agent has detected a Compaq Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the server lost power, that data has been lost. User Action: Verify that no data has been lost.\"",
    "::=",
    "16005"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSsChassisName",
        "cpqSsChassisTime",
        "cpqFcaAccelBoxIoSlot"
      ]
    ],
    [
      "DESCRIPTION",
      "Accelerator Board Bad Data. This trap signifies that the Insight Agent has detected a Compaq Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the server lost power, that data has been lost. User Action: Verify that no data has been lost."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQFCA-MIB

    Published definition
    cpqFcaAccelBadDataTrap TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsChassisName,
                         cpqSsChassisTime, cpqFcaAccelBoxIoSlot }
            DESCRIPTION
                "Accelerator Board Bad Data.
    
                This trap signifies that the Insight Agent has detected a
                Compaq Array Accelerator Cache Board that has lost battery
                power.  If data was being stored in the accelerator memory
                when the server lost power, that data has been lost.
    
                User Action: Verify that no data has been lost."
    
            --#TYPE "Accelerator Board Bad Data"
            --#SUMMARY "Accelerator lost battery power.  Data Loss possible."
            --#ARGUMENTS {}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
    
            ::= 16005
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSTSYS-MIB': ['cpqSsChassisName', 'cpqSsChassisTime']}
    · Download Cpqfca.mib.txt
    Source location: CPQFCA-MIB::cpqFcaAccelBadDataTrap.
    Source version and references

    Archived: 2026-10-19T00:22:07.818338+00:00.

cpqFcaAccelBadDataTrap

Status in source: unspecified.

Names: cpqFcaAccelBadDataTrap

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqFcaAccelBadDataTrap",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSsChassisName",
    ",",
    "cpqSsChassisTime",
    ",",
    "cpqFcaAccelBoxIoSlot",
    "}",
    "DESCRIPTION",
    "\"External Array Accelerator Board Bad Data. This trap signifies that the agent has detected a Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the system lost power, that data has been lost. User Action: Verify that no data has been lost.\"",
    "::=",
    "16005"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSsChassisName",
        "cpqSsChassisTime",
        "cpqFcaAccelBoxIoSlot"
      ]
    ],
    [
      "DESCRIPTION",
      "External Array Accelerator Board Bad Data. This trap signifies that the agent has detected a Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the system lost power, that data has been lost. User Action: Verify that no data has been lost."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQFCA-MIB

    Published definition
    cpqFcaAccelBadDataTrap TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsChassisName,
                         cpqSsChassisTime, cpqFcaAccelBoxIoSlot }
            DESCRIPTION
                "External Array Accelerator Board Bad Data.
    
                This trap signifies that the agent has detected a Array
                Accelerator Cache Board that has lost battery power.  If data
                was being stored in the accelerator memory when the system lost
                power, that data has been lost.
    
                User Action: Verify that no data has been lost."
    
            --#TYPE "External Array Accelerator Board Bad Data (16005)"
            --#SUMMARY "Accelerator lost battery power.  Data Loss possible."
            --#ARGUMENTS {}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
    
            ::= 16005
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSTSYS-MIB': ['cpqSsChassisName', 'cpqSsChassisTime']}
    · Download CPQFCA.MIB.txt
    Source location: CPQFCA-MIB::cpqFcaAccelBadDataTrap.
    Source version and references

    Archived: 2026-10-19T00:22:08.775618+00:00.

  • Preserved circitor archive

    Module: CPQFCA-MIB

    Published definition
    cpqFcaAccelBadDataTrap TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsChassisName,
                         cpqSsChassisTime, cpqFcaAccelBoxIoSlot }
            DESCRIPTION
                "External Array Accelerator Board Bad Data.
    
                This trap signifies that the agent has detected a Array
                Accelerator Cache Board that has lost battery power.  If data
                was being stored in the accelerator memory when the system lost
                power, that data has been lost.
    
                User Action: Verify that no data has been lost."
    
            --#TYPE "External Array Accelerator Board Bad Data (16005)"
            --#SUMMARY "Accelerator lost battery power.  Data Loss possible."
            --#ARGUMENTS {}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
    
            ::= 16005
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSTSYS-MIB': ['cpqSsChassisName', 'cpqSsChassisTime']}
    · Download CPQFCA-MIB.mib
    Source location: CPQFCA-MIB::cpqFcaAccelBadDataTrap.
    Source version and references

    Archived: 2026-10-19T00:22:16.762605+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQFCA-MIB

    Published definition
    cpqFcaAccelBadDataTrap TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsChassisName,
                         cpqSsChassisTime, cpqFcaAccelBoxIoSlot }
            DESCRIPTION
                "External Array Accelerator Board Bad Data.
    
                This trap signifies that the agent has detected a Array
                Accelerator Cache Board that has lost battery power.  If data
                was being stored in the accelerator memory when the system lost
                power, that data has been lost.
    
                User Action: Verify that no data has been lost."
    
            --#TYPE "External Array Accelerator Board Bad Data (16005)"
            --#SUMMARY "Accelerator lost battery power.  Data Loss possible."
            --#ARGUMENTS {}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
    
            ::= 16005
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSTSYS-MIB': ['cpqSsChassisName', 'cpqSsChassisTime']}
    · Download CPQFCA-MIB

    Related source files and packages:


    Source location: CPQFCA-MIB::cpqFcaAccelBadDataTrap.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.594295+00:00.

cpqFcaAccelBadDataTrap

Status in source: unspecified.

Names: cpqFcaAccelBadDataTrap

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqFcaAccelBadDataTrap",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSsChassisName",
    ",",
    "cpqSsChassisTime",
    ",",
    "cpqFcaAccelBoxIoSlot",
    "}",
    "DESCRIPTION",
    "\"Fibre Channel Array Accelerator Board Bad Data. This trap signifies that the agent has detected a Compaq Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the system lost power, that data has been lost. User Action: Verify that no data has been lost.\"",
    "::=",
    "16005"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSsChassisName",
        "cpqSsChassisTime",
        "cpqFcaAccelBoxIoSlot"
      ]
    ],
    [
      "DESCRIPTION",
      "Fibre Channel Array Accelerator Board Bad Data. This trap signifies that the agent has detected a Compaq Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the system lost power, that data has been lost. User Action: Verify that no data has been lost."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQFCA-MIB

    Published definition
    cpqFcaAccelBadDataTrap TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsChassisName,
                         cpqSsChassisTime, cpqFcaAccelBoxIoSlot }
            DESCRIPTION
                "Fibre Channel Array Accelerator Board Bad Data.
    
                This trap signifies that the agent has detected a Compaq Array
                Accelerator Cache Board that has lost battery power.  If data
                was being stored in the accelerator memory when the system lost
                power, that data has been lost.
    
                User Action: Verify that no data has been lost."
    
            --#TYPE "Accelerator Board Bad Data"
            --#SUMMARY "Accelerator lost battery power.  Data Loss possible."
            --#ARGUMENTS {}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
    
            ::= 16005
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSTSYS-MIB': ['cpqSsChassisName', 'cpqSsChassisTime']}
    · Download CPQFCA2.MIB.txt
    Source location: CPQFCA-MIB::cpqFcaAccelBadDataTrap.
    Source version and references

    Archived: 2026-10-19T00:22:08.776600+00:00.

  • Preserved mibdepot archive

    Module: CPQFCA-MIB

    Published definition
    cpqFcaAccelBadDataTrap TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsChassisName,
                         cpqSsChassisTime, cpqFcaAccelBoxIoSlot }
            DESCRIPTION
                "Fibre Channel Array Accelerator Board Bad Data.
    
                This trap signifies that the agent has detected a Compaq Array
                Accelerator Cache Board that has lost battery power.  If data
                was being stored in the accelerator memory when the system lost
                power, that data has been lost.
    
                User Action: Verify that no data has been lost."
    
            --#TYPE "Accelerator Board Bad Data"
            --#SUMMARY "Accelerator lost battery power.  Data Loss possible."
            --#ARGUMENTS {}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
    
            ::= 16005
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSTSYS-MIB': ['cpqSsChassisName', 'cpqSsChassisTime']}
    · Download cpqfca1.mib.txt
    Source location: CPQFCA-MIB::cpqFcaAccelBadDataTrap.
    Source version and references

    Archived: 2026-10-19T00:22:08.856558+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.22030 cpqRackPowerChassisNotLoadBalanced00
1.3.6.1.4.1.232.0.22031 cpqRackPowerChassisDcPowerProblem00
1.3.6.1.4.1.232.0.22032 cpqRackPowerChassisAcFacilityPowerExceeded00
1.3.6.1.4.1.232.0.22033 cpqRackPowerUnknownPowerConsumption00
1.3.6.1.4.1.232.0.22034 cpqRackPowerChassisLoadBalancingWireMissing00
1.3.6.1.4.1.232.0.22035 cpqRackPowerChassisTooManyPowerChassis00
1.3.6.1.4.1.232.0.22036 cpqRackPowerChassisConfigError00
1.3.6.1.4.1.232.0.22037 cpqRackEnclosureManagerDegraded00
1.3.6.1.4.1.232.0.22038 cpqRackEnclosureManagerOk00
1.3.6.1.4.1.232.0.22039 cpqRackEnclosureManagerRemoved00
1.3.6.1.4.1.232.0.22040 cpqRackEnclosureManagerInserted00
1.3.6.1.4.1.232.0.22041 cpqRackManagerPrimaryRole00
1.3.6.1.4.1.232.0.22042 cpqRackServerBladeEKeyingFailed00
1.3.6.1.4.1.232.0.22043 cpqRackServerBladeEKeyingOK00
1.3.6.1.4.1.232.0.22044 cpqRackNetConnectorRemoved00
1.3.6.1.4.1.232.0.22045 cpqRackNetConnectorInserted00
1.3.6.1.4.1.232.0.22046 cpqRackNetConnectorFailed00
1.3.6.1.4.1.232.0.22047 cpqRackNetConnectorDegraded00
1.3.6.1.4.1.232.0.22048 cpqRackNetConnectorOk00
1.3.6.1.4.1.232.0.22049 cpqRackServerBladeToLowPower00
1.3.6.1.4.1.232.0.22050 cpqRackServerBladeRemoved200
1.3.6.1.4.1.232.0.22051 cpqRackServerBladeInserted200
1.3.6.1.4.1.232.0.22052 cpqRackServerBladeStatusRepaired00
1.3.6.1.4.1.232.0.22053 cpqRackServerBladeStatusDegraded00
1.3.6.1.4.1.232.0.22054 cpqRackServerBladeStatusCritical00
1.3.6.1.4.1.232.0.22055 cpqRackServerBladeGrpCapTimeout00
1.3.6.1.4.1.232.0.22056 cpqRackServerBladeUnexpectedShutdown00
1.3.6.1.4.1.232.0.22057 cpqRackServerBladeMangementControllerFirmwareUpdating00
1.3.6.1.4.1.232.0.22058 cpqRackServerBladeMangementControllerFirmwareUpdateComplete00
1.3.6.1.4.1.232.0.22059 cpqRackServerBladeSystemBIOSFirmwareUpdating00
1.3.6.1.4.1.232.0.22060 cpqRackServerBladeSystemBIOSFirmwareUpdateCompleted00
1.3.6.1.4.1.232.0.22061 cpqRackServerBladeFrontIOBlankingActive00
1.3.6.1.4.1.232.0.22062 cpqRackServerBladeRemoteFrontIOBlankingInactive00
1.3.6.1.4.1.232.0.22063 cpqRackServerBladeDiagnosticAdaptorInserted00
1.3.6.1.4.1.232.0.22064 cpqRackServerBladeDiagnosticAdaptorRemoved00
1.3.6.1.4.1.232.0.22065 cpqRackServerBladeEnteredPXEBootMode00
1.3.6.1.4.1.232.0.22066 cpqRackServerBladeExitedPXEBootMode00
1.3.6.1.4.1.232.0.22067 cpqRackServerBladeWarmReset00
1.3.6.1.4.1.232.0.22068 cpqRackServerBladePOSTCompleted00
1.3.6.1.4.1.232.0.22069 cpqRackServerBladePoweredOn00
1.3.6.1.4.1.232.0.22070 cpqRackServerBladePoweredOff00
1.3.6.1.4.1.232.0.22071 cpqRackInformationalEAETrap00
1.3.6.1.4.1.232.0.22072 cpqRackMinorEAETrap00
1.3.6.1.4.1.232.0.22073 cpqRackMajorEAETrap00
1.3.6.1.4.1.232.0.22074 cpqRackCriticalEAETrap00
1.3.6.1.4.1.232.0.22075 cpqRackPowerMinorEAETrap00
1.3.6.1.4.1.232.0.22076 cpqRackPowerMajorEAETrap00
1.3.6.1.4.1.232.0.22077 cpqRackPowerCriticalEAETrap00
1.3.6.1.4.1.232.0.22078 cpqRackServerBladePartitionChange00
1.3.6.1.4.1.232.0.22079 cpqRackInformationalWSMANTrap00