Reference record for OID 1.3.6.1.4.1.232.0.18002

Parent
1.3.6.1.4.1.232.0 (0)
Node code
18002
Node name
cpqNicConnectivityLost
Numeric OID
1.3.6.1.4.1.232.0.18002
URN notation
urn:oid:1.3.6.1.4.1.232.0.18002
ASN.1 notation

{1 3 6 1 4 1 232 0 18002}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNicConnectivityLost(18002)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNicConnectivityLost(18002)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/18002
  • /ISO/Identified-Organization/6/1/4/1/232/0/18002
  • /ISO/3/6/1/4/1/232/0/18002
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqNicConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqNicConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqNicConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqNicConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqNicConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqNicConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqNicConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqNicConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqNicConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqNicConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqNicConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqNicConnectivityLost
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqNicConnectivityLost
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqNicConnectivityLost
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqNicConnectivityLost
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqNicConnectivityLost
  • Additional combinations skipped.

Descriptions

cpqNicConnectivityLost — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.

Source records

cpqNicConnectivityLost

Status in source: unspecified.

Names: cpqNicConnectivityLost

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNicConnectivityLost",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.\"",
    "::=",
    "18002"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNicConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "Status Trap"
                 --#SUMMARY "Connectivity lost for adapter in slot %s, port %s."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 18
            ::= 18002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Cpqnic.mib.txt
    Source location: CPQNIC-MIB::cpqNicConnectivityLost.
    Source version and references

    Archived: 2026-10-19T00:22:07.818687+00:00.

  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNicConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Status Trap (18002)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
            ::= 18002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC.MIB.txt
    Source location: CPQNIC-MIB::cpqNicConnectivityLost.
    Source version and references

    Archived: 2026-10-19T00:22:08.785287+00:00.

  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNicConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Status Trap"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
            ::= 18002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC1.MIB.txt
    Source location: CPQNIC-MIB::cpqNicConnectivityLost.
    Source version and references

    Archived: 2026-10-19T00:22:08.785752+00:00.

  • Preserved circitor archive

    Module: CPQNIC-MIB

    Published definition
    cpqNicConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Status Trap (18002)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
            ::= 18002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB.mib
    Source location: CPQNIC-MIB::cpqNicConnectivityLost.
    Source version and references

    Archived: 2026-10-19T00:22:16.786453+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQNIC-MIB

    Published definition
    cpqNicConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Status Trap (18002)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
                 --#SIMPLE_SEVERITY MAJOR
                 --#HWSTATUS_CATEGORY NETWORK
                 --#ACTION "Check the cables to the adapter and the Hub or Switch.  If no cable problems are found, the adapter, Hub, or Switch may need replacement."
                              
            ::= 18002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB

    Related source files and packages:


    Source location: CPQNIC-MIB::cpqNicConnectivityLost.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.096280+00:00.

  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNicConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "Status Trap"
                 --#SUMMARY "Connectivity lost for adapter in slot %s, port %s."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 18
            ::= 18002
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}

    Source data warning: This historical publication omits an explicitly reviewed standard root import. Exact original declarations and all numeric values are retained; the referenced RFC and IANA allocation establish only the missing standard namespace.

    · Download Compaq-Nic.mib.txt

    Related source files and packages:


    Source location: CPQNIC-MIB::cpqNicConnectivityLost.
    Source version and references

    Archived: 2026-10-19T00:22:08.801046+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.9026 cpqSm2FwUpdateUploadFailed00
1.3.6.1.4.1.232.0.9027 cpqSm2SecurityStateChange00
1.3.6.1.4.1.232.0.9028 cpqSm2WDTimerReset00
1.3.6.1.4.1.232.0.9029 cpqSm2OverallSecStateAtRisk00
1.3.6.1.4.1.232.0.9030 cpqSm2OverallSecStatusChange00
1.3.6.1.4.1.232.0.10001 cpqMeRisingAlarm00
1.3.6.1.4.1.232.0.10002 cpqMeFallingAlarm00
1.3.6.1.4.1.232.0.10003 cpqMe2RisingAlarm00
1.3.6.1.4.1.232.0.10004 cpqMe2FallingAlarm00
1.3.6.1.4.1.232.0.10005 cpqMeRisingAlarmExtended00
1.3.6.1.4.1.232.0.10006 cpqMeFallingAlarmExtended00
1.3.6.1.4.1.232.0.10007 cpqMeCriticalRisingAlarmExtended00
1.3.6.1.4.1.232.0.10008 cpqMeCriticalFallingAlarmExtended00
1.3.6.1.4.1.232.0.11001 cpqHoGenericTrap00
1.3.6.1.4.1.232.0.11002 cpqHoAppErrorTrap00
1.3.6.1.4.1.232.0.11003 cpqHo2GenericTrap00
1.3.6.1.4.1.232.0.11004 cpqHo2AppErrorTrap00
1.3.6.1.4.1.232.0.11005 cpqHo2NicStatusOk00
1.3.6.1.4.1.232.0.11006 cpqHo2NicStatusFailed00
1.3.6.1.4.1.232.0.11007 cpqHo2NicSwitchoverOccurred00
1.3.6.1.4.1.232.0.11008 cpqHo2NicStatusOk200
1.3.6.1.4.1.232.0.11009 cpqHo2NicStatusFailed200
1.3.6.1.4.1.232.0.11010 cpqHo2NicSwitchoverOccurred200
1.3.6.1.4.1.232.0.11011 cpqHoProcessEventTrap00
1.3.6.1.4.1.232.0.11012 cpqHoProcessCountWarning00
1.3.6.1.4.1.232.0.11013 cpqHoProcessCountNormal00
1.3.6.1.4.1.232.0.11014 cpqHoCriticalSoftwareUpdateTrap00
1.3.6.1.4.1.232.0.11015 cpqHoCrashDumpNotEnabledTrap00
1.3.6.1.4.1.232.0.11016 cpqHoBootPagingFileTooSmallTrap00
1.3.6.1.4.1.232.0.11017 cpqHoSWRunningStatusChangeTrap00
1.3.6.1.4.1.232.0.11018 cpqHo2PowerThresholdTrap00
1.3.6.1.4.1.232.0.11019 cpqHoBootPagingFileOrFreeSpaceTooSmallTrap00
1.3.6.1.4.1.232.0.11020 cpqHoMibHealthStatusArrayChangeTrap00
1.3.6.1.4.1.232.0.12001 cpqUpsLineFailed00
1.3.6.1.4.1.232.0.12002 cpqUpsLineOk00
1.3.6.1.4.1.232.0.12003 cpqUpsShutdown00
1.3.6.1.4.1.232.0.12004 cpqUpsConfirmation00
1.3.6.1.4.1.232.0.12005 cpqUpsBatteryLow00
1.3.6.1.4.1.232.0.12006 cpqUps2LineFailed00
1.3.6.1.4.1.232.0.12007 cpqUps2LineOk00
1.3.6.1.4.1.232.0.12008 cpqUps2Shutdown00
1.3.6.1.4.1.232.0.12009 cpqUps2Confirmation00
1.3.6.1.4.1.232.0.12010 cpqUps2BatteryLow00
1.3.6.1.4.1.232.0.12011 cpqUpsOverload00
1.3.6.1.4.1.232.0.12012 cpqUpsPendingBatteryFailure00
1.3.6.1.4.1.232.0.12013 cpqUpsGenericCritical00
1.3.6.1.4.1.232.0.12014 cpqUpsGenericInfo00
1.3.6.1.4.1.232.0.13001 cpqRsPartnerFailed00
1.3.6.1.4.1.232.0.13002 cpqRsStandbyCableFailure00
1.3.6.1.4.1.232.0.13003 cpqRsStandbyFailure00