Reference record for OID 1.3.6.1.4.1.232.0.18008

Parent
1.3.6.1.4.1.232.0 (0)
Node code
18008
Node name
cpqNic2RedundancyReduced
Numeric OID
1.3.6.1.4.1.232.0.18008
URN notation
urn:oid:1.3.6.1.4.1.232.0.18008
ASN.1 notation

{1 3 6 1 4 1 232 0 18008}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic2RedundancyReduced(18008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic2RedundancyReduced(18008)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/18008
  • /ISO/Identified-Organization/6/1/4/1/232/0/18008
  • /ISO/3/6/1/4/1/232/0/18008
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqNic2RedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqNic2RedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqNic2RedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqNic2RedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqNic2RedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqNic2RedundancyReduced
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqNic2RedundancyReduced
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqNic2RedundancyReduced
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqNic2RedundancyReduced
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqNic2RedundancyReduced
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqNic2RedundancyReduced
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqNic2RedundancyReduced
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqNic2RedundancyReduced
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqNic2RedundancyReduced
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqNic2RedundancyReduced
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqNic2RedundancyReduced
  • Additional combinations skipped.

Descriptions

cpqNic2RedundancyReduced — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.

Source records

cpqNic2RedundancyReduced

Status in source: unspecified.

Names: cpqNic2RedundancyReduced

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNic2RedundancyReduced",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    ",",
    "cpqSiServerSystemId",
    ",",
    "cpqNicIfPhysAdapterStatus",
    ",",
    "cpqSePciSlotBoardName",
    ",",
    "cpqNicIfPhysAdapterPartNumber",
    ",",
    "ipAdEntAddr",
    ",",
    "cpqNicIfLogMapAdapterOKCount",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.\"",
    "::=",
    "18008"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort",
        "cpqSiServerSystemId",
        "cpqNicIfPhysAdapterStatus",
        "cpqSePciSlotBoardName",
        "cpqNicIfPhysAdapterPartNumber",
        "ipAdEntAddr",
        "cpqNicIfLogMapAdapterOKCount"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic2RedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr,
                        cpqNicIfLogMapAdapterOKCount }
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Redundancy Reduced Trap (18008)"
                 --#SUMMARY "Redundancy decreased by adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
            ::= 18008
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC.MIB.txt
    Source location: CPQNIC-MIB::cpqNic2RedundancyReduced.
    Source version and references

    Archived: 2026-10-19T00:22:08.785287+00:00.

  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic2RedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr,
                        cpqNicIfLogMapAdapterOKCount }
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Redundancy Reduced Trap"
                 --#SUMMARY "Redundancy decreased by adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
            ::= 18008
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC1.MIB.txt
    Source location: CPQNIC-MIB::cpqNic2RedundancyReduced.
    Source version and references

    Archived: 2026-10-19T00:22:08.785752+00:00.

  • Preserved circitor archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic2RedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr,
                        cpqNicIfLogMapAdapterOKCount }
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Redundancy Reduced Trap (18008)"
                 --#SUMMARY "Redundancy decreased by adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
            ::= 18008
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB.mib
    Source location: CPQNIC-MIB::cpqNic2RedundancyReduced.
    Source version and references

    Archived: 2026-10-19T00:22:16.786453+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQNIC-MIB

    Published definition
    cpqNic2RedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr,
                        cpqNicIfLogMapAdapterOKCount }
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Redundancy Reduced Trap (18008)"
                 --#SUMMARY "Redundancy decreased by adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
                 --#SIMPLE_SEVERITY MAJOR
                 --#HWSTATUS_CATEGORY NETWORK
                 --#ACTION "Check the cables to the adapter and the Hub or Switch.  If no cable problems are found, the adapter, Hub, or Switch may need replacement."
                              
            ::= 18008
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB

    Related source files and packages:


    Source location: CPQNIC-MIB::cpqNic2RedundancyReduced.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.096280+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.13603620 sCellEventTrap-0e-2400
1.3.6.1.4.1.232.0.13603621 sCellEventTrap-0e-2500
1.3.6.1.4.1.232.0.13603622 sCellEventTrap-0e-2600
1.3.6.1.4.1.232.0.13603623 sCellEventTrap-0e-2700
1.3.6.1.4.1.232.0.13603624 sCellEventTrap-0e-2800
1.3.6.1.4.1.232.0.13603625 sCellEventTrap-0e-2900
1.3.6.1.4.1.232.0.13603626 sCellEventTrap-0e-2a00
1.3.6.1.4.1.232.0.13603627 sCellEventTrap-0e-2b00
1.3.6.1.4.1.232.0.13603628 sCellEventTrap-0e-2c00
1.3.6.1.4.1.232.0.13603629 sCellEventTrap-0e-2d00
1.3.6.1.4.1.232.0.13603630 sCellEventTrap-0e-2e00
1.3.6.1.4.1.232.0.13603631 sCellEventTrap-0e-2f00
1.3.6.1.4.1.232.0.13603636 sCellEventTrap-0e-3400
1.3.6.1.4.1.232.0.13603637 sCellEventTrap-0e-3500
1.3.6.1.4.1.232.0.13603638 sCellEventTrap-0e-3600
1.3.6.1.4.1.232.0.13603639 sCellEventTrap-0e-3700
1.3.6.1.4.1.232.0.13603640 sCellEventTrap-0e-3800
1.3.6.1.4.1.232.0.13603641 sCellEventTrap-0e-3900
1.3.6.1.4.1.232.0.13603642 sCellEventTrap-0e-3a00
1.3.6.1.4.1.232.0.13603643 sCellEventTrap-0e-3b00
1.3.6.1.4.1.232.0.13603644 sCellEventTrap-0e-3c00
1.3.6.1.4.1.232.0.13603645 sCellEventTrap-0e-3d00
1.3.6.1.4.1.232.0.13603646 sCellEventTrap-0e-3e00
1.3.6.1.4.1.232.0.13603647 sCellEventTrap-0e-3f00
1.3.6.1.4.1.232.0.13603648 sCellEventTrap-0e-4000
1.3.6.1.4.1.232.0.13603649 sCellEventTrap-0e-4100
1.3.6.1.4.1.232.0.13603650 sCellEventTrap-0e-4200
1.3.6.1.4.1.232.0.13603651 sCellEventTrap-0e-4300
1.3.6.1.4.1.232.0.13603652 sCellEventTrap-0e-4400
1.3.6.1.4.1.232.0.13603653 sCellEventTrap-0e-4500
1.3.6.1.4.1.232.0.13603654 sCellEventTrap-0e-4600
1.3.6.1.4.1.232.0.13603655 sCellEventTrap-0e-4700
1.3.6.1.4.1.232.0.13603656 sCellEventTrap-0e-4800
1.3.6.1.4.1.232.0.13603657 sCellEventTrap-0e-4900
1.3.6.1.4.1.232.0.13603658 sCellEventTrap-0e-4a00
1.3.6.1.4.1.232.0.13603659 sCellEventTrap-0e-4b00
1.3.6.1.4.1.232.0.13603660 sCellEventTrap-0e-4c00
1.3.6.1.4.1.232.0.13603661 sCellEventTrap-0e-4d00
1.3.6.1.4.1.232.0.13603662 sCellEventTrap-0e-4e00
1.3.6.1.4.1.232.0.13603663 sCellEventTrap-0e-4f00
1.3.6.1.4.1.232.0.13603664 sCellEventTrap-0e-5000
1.3.6.1.4.1.232.0.13603665 sCellEventTrap-0e-5100
1.3.6.1.4.1.232.0.13603666 sCellEventTrap-0e-5200
1.3.6.1.4.1.232.0.13603667 sCellEventTrap-0e-5300
1.3.6.1.4.1.232.0.13603668 sCellEventTrap-0e-5400
1.3.6.1.4.1.232.0.13603669 sCellEventTrap-0e-5500
1.3.6.1.4.1.232.0.13603670 sCellEventTrap-0e-5600
1.3.6.1.4.1.232.0.13603671 sCellEventTrap-0e-5700
1.3.6.1.4.1.232.0.13603712 sCellEventTrap-0e-8000
1.3.6.1.4.1.232.0.13603713 sCellEventTrap-0e-8100