Reference record for OID 1.3.6.1.4.1.232.0.18012

Parent
1.3.6.1.4.1.232.0 (0)
Node code
18012
Node name
cpqNic3ConnectivityLost
Numeric OID
1.3.6.1.4.1.232.0.18012
URN notation
urn:oid:1.3.6.1.4.1.232.0.18012
ASN.1 notation

{1 3 6 1 4 1 232 0 18012}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/18012
  • /ISO/Identified-Organization/6/1/4/1/232/0/18012
  • /ISO/3/6/1/4/1/232/0/18012
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqNic3ConnectivityLost
  • Additional combinations skipped.

Descriptions

cpqNic3ConnectivityLost — Circitor, MIBdepot

This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.

cpqNic3ConnectivityLost — HPE networking MIB copies (LibreNMS/Observium Community)

This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections.

Source records

cpqNic3ConnectivityLost

Status in source: unspecified.

Names: cpqNic3ConnectivityLost

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNic3ConnectivityLost",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    ",",
    "cpqSiServerSystemId",
    ",",
    "cpqNicIfPhysAdapterStatus",
    ",",
    "cpqSePciSlotBoardName",
    ",",
    "cpqNicIfPhysAdapterPartNumber",
    ",",
    "ipAdEntAddr",
    ",",
    "cpqNicIfLogMapIPV6Address",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.\"",
    "::=",
    "18012"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort",
        "cpqSiServerSystemId",
        "cpqNicIfPhysAdapterStatus",
        "cpqSePciSlotBoardName",
        "cpqNicIfPhysAdapterPartNumber",
        "ipAdEntAddr",
        "cpqNicIfLogMapIPV6Address"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic3ConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Connectivity Lost Trap (18012)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 18
                 --#STATE NONOPERATIONAL
            ::= 18012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC.MIB.txt
    Source location: CPQNIC-MIB::cpqNic3ConnectivityLost.
    Source version and references

    Archived: 2026-10-19T00:22:08.785287+00:00.

  • Preserved circitor archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic3ConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Connectivity Lost Trap (18012)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 18
                 --#STATE NONOPERATIONAL
            ::= 18012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB.mib
    Source location: CPQNIC-MIB::cpqNic3ConnectivityLost.
    Source version and references

    Archived: 2026-10-19T00:22:16.786453+00:00.

cpqNic3ConnectivityLost

Status in source: unspecified.

Names: cpqNic3ConnectivityLost

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNic3ConnectivityLost",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    ",",
    "cpqSiServerSystemId",
    ",",
    "cpqNicIfPhysAdapterStatus",
    ",",
    "cpqSePciSlotBoardName",
    ",",
    "cpqNicIfPhysAdapterPartNumber",
    ",",
    "ipAdEntAddr",
    ",",
    "cpqNicIfLogMapIPV6Address",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections.\"",
    "::=",
    "18012"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort",
        "cpqSiServerSystemId",
        "cpqNicIfPhysAdapterStatus",
        "cpqSePciSlotBoardName",
        "cpqNicIfPhysAdapterPartNumber",
        "ipAdEntAddr",
        "cpqNicIfLogMapIPV6Address"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQNIC-MIB

    Published definition
    cpqNic3ConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address }
            DESCRIPTION
                "This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections."
    
                 --#TYPE "NIC Connectivity Lost Trap (18012)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 18
                 --#STATE NONOPERATIONAL
                 --#SIMPLE_SEVERITY MAJOR
                 --#HWSTATUS_CATEGORY NETWORK
                 --#ACTION "If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the switch or interconnect. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert indicates a loss of connectivity between the network adapter and the switch or interconnect. Check the physical connection from the server to its destination device such as interconnect ,blade, switch etc, including any cables. Also check the configuration of the operating system and destination device."
                              
            ::= 18012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB

    Related source files and packages:


    Source location: CPQNIC-MIB::cpqNic3ConnectivityLost.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.096280+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.22080 cpqRackMinorWSMANTrap00
1.3.6.1.4.1.232.0.22081 cpqRackMajorWSMANTrap00
1.3.6.1.4.1.232.0.22082 cpqRackCriticalWSMANTrap00
1.3.6.1.4.1.232.0.22083 cpqRackEnclosureManagerLinkDown00
1.3.6.1.4.1.232.0.22084 cpqRackEnclosureManagerLinkUp00
1.3.6.1.4.1.232.0.22085 cpqRackErsCommFailure00
1.3.6.1.4.1.232.0.22086 cpqRackPowerSubsystemOverloadConditionRepaired00
1.3.6.1.4.1.232.0.22087 cpqRackPowerSubsystemRedundancyOk00
1.3.6.1.4.1.232.0.22088 cpqRackNetConnectorTempDegraded00
1.3.6.1.4.1.232.0.22089 cpqRackNetConnectorTempOk00
1.3.6.1.4.1.232.0.22090 cpqRackEnvironmentalLeakDetected00
1.3.6.1.4.1.232.0.22091 cpqRackEnvironmentalDoorState00
1.3.6.1.4.1.232.0.22092 cpqRackEnvironmentalAirTempSensor00
1.3.6.1.4.1.232.0.22093 cpqRackEnvironmentalControlValveStatus00
1.3.6.1.4.1.232.0.22094 cpqRackEnvironmentalWaterTempThresholdExceeded00
1.3.6.1.4.1.232.0.22095 cpqRackEnvironmentalFlowSensorStatus00
1.3.6.1.4.1.232.0.22096 cpqRackEnvironmentalWaterPressureThresholdExceeded00
1.3.6.1.4.1.232.0.22097 cpqRackEnvironmentalAutomaticRapidPowerOff00
1.3.6.1.4.1.232.0.22098 cpqRackEnvironmentalRopeLeakDetectorEvent00
1.3.6.1.4.1.232.0.22099 cpqRackEnvironmentalTemperatureThresholdExceeded00
1.3.6.1.4.1.232.0.22100 cpqRackEnvironmentalHumidityThresholdExceeded00
1.3.6.1.4.1.232.0.22101 cpqRackEnvironmentalControllerOnBoardBattery00
1.3.6.1.4.1.232.0.22102 cpqRackEnvironmentalControllerAPMCommunicationFailure00
1.3.6.1.4.1.232.0.22103 cpqRackEnvironmentalLeakDetectedCritical00
1.3.6.1.4.1.232.0.22104 cpqRackPowerSubsystemReductionModeActivate00
1.3.6.1.4.1.232.0.22105 cpqRackPowerSubsystemReductionModeDeactivate00
1.3.6.1.4.1.232.0.23001 cpqNodeTemperatureDegraded00
1.3.6.1.4.1.232.0.23002 cpqNodeTemperatureOk00
1.3.6.1.4.1.232.0.23003 cpqNodeTemperatureFailed00
1.3.6.1.4.1.232.0.23004 cpqNodeErrorEvent00
1.3.6.1.4.1.232.0.23010 cpqNodePowerOn00
1.3.6.1.4.1.232.0.23011 cpqNodePowerOff00
1.3.6.1.4.1.232.0.99999 cpqGenericUnregistered00
1.3.6.1.4.1.232.0.136001 emuEventTrapInformative00
1.3.6.1.4.1.232.0.136002 emuEventTrapNoncritical00
1.3.6.1.4.1.232.0.136003 emuEventTrapCritical00
1.3.6.1.4.1.232.0.136004 emuEventTrapUnrecoverable00
1.3.6.1.4.1.232.0.140001 cpqICAAdd00
1.3.6.1.4.1.232.0.140002 cpqICADelete00
1.3.6.1.4.1.232.0.140003 cpqICAPropertyChange00
1.3.6.1.4.1.232.0.140004 cpqICAMove00
1.3.6.1.4.1.232.0.140005 cpqICAImportRestoreStart00
1.3.6.1.4.1.232.0.140006 cpqICAImportRestoreEnd00
1.3.6.1.4.1.232.0.150001 cpqDMIIndicationInfo00
1.3.6.1.4.1.232.0.150002 cpqDMIIndicationMonitor00
1.3.6.1.4.1.232.0.150003 cpqDMIIndicationOK00
1.3.6.1.4.1.232.0.150004 cpqDMIIndicationNonCritical00
1.3.6.1.4.1.232.0.150005 cpqDMIIndicationCritical00
1.3.6.1.4.1.232.0.150006 cpqDMIIndicationNonNonRecoverable00
1.3.6.1.4.1.232.0.161001 switchFirmwareTransferred00