Reference record for OID 1.3.6.1.4.1.232.0.18012

Parent
1.3.6.1.4.1.232.0 (0)
Node code
18012
Node name
cpqNic3ConnectivityLost
Numeric OID
1.3.6.1.4.1.232.0.18012
URN notation
urn:oid:1.3.6.1.4.1.232.0.18012
ASN.1 notation

{1 3 6 1 4 1 232 0 18012}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/18012
  • /ISO/Identified-Organization/6/1/4/1/232/0/18012
  • /ISO/3/6/1/4/1/232/0/18012
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqNic3ConnectivityLost
  • Additional combinations skipped.

Descriptions

cpqNic3ConnectivityLost — Circitor, MIBdepot

This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.

cpqNic3ConnectivityLost — HPE networking MIB copies (LibreNMS/Observium Community)

This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections.

Source records

cpqNic3ConnectivityLost

Status in source: unspecified.

Names: cpqNic3ConnectivityLost

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNic3ConnectivityLost",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    ",",
    "cpqSiServerSystemId",
    ",",
    "cpqNicIfPhysAdapterStatus",
    ",",
    "cpqSePciSlotBoardName",
    ",",
    "cpqNicIfPhysAdapterPartNumber",
    ",",
    "ipAdEntAddr",
    ",",
    "cpqNicIfLogMapIPV6Address",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.\"",
    "::=",
    "18012"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort",
        "cpqSiServerSystemId",
        "cpqNicIfPhysAdapterStatus",
        "cpqSePciSlotBoardName",
        "cpqNicIfPhysAdapterPartNumber",
        "ipAdEntAddr",
        "cpqNicIfLogMapIPV6Address"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic3ConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Connectivity Lost Trap (18012)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 18
                 --#STATE NONOPERATIONAL
            ::= 18012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC.MIB.txt
    Source location: CPQNIC-MIB::cpqNic3ConnectivityLost.
    Source version and references

    Archived: 2026-10-19T00:22:08.785287+00:00.

  • Preserved circitor archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic3ConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Connectivity Lost Trap (18012)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 18
                 --#STATE NONOPERATIONAL
            ::= 18012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB.mib
    Source location: CPQNIC-MIB::cpqNic3ConnectivityLost.
    Source version and references

    Archived: 2026-10-19T00:22:16.786453+00:00.

cpqNic3ConnectivityLost

Status in source: unspecified.

Names: cpqNic3ConnectivityLost

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNic3ConnectivityLost",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    ",",
    "cpqSiServerSystemId",
    ",",
    "cpqNicIfPhysAdapterStatus",
    ",",
    "cpqSePciSlotBoardName",
    ",",
    "cpqNicIfPhysAdapterPartNumber",
    ",",
    "ipAdEntAddr",
    ",",
    "cpqNicIfLogMapIPV6Address",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections.\"",
    "::=",
    "18012"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort",
        "cpqSiServerSystemId",
        "cpqNicIfPhysAdapterStatus",
        "cpqSePciSlotBoardName",
        "cpqNicIfPhysAdapterPartNumber",
        "ipAdEntAddr",
        "cpqNicIfLogMapIPV6Address"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQNIC-MIB

    Published definition
    cpqNic3ConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address }
            DESCRIPTION
                "This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections."
    
                 --#TYPE "NIC Connectivity Lost Trap (18012)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 18
                 --#STATE NONOPERATIONAL
                 --#SIMPLE_SEVERITY MAJOR
                 --#HWSTATUS_CATEGORY NETWORK
                 --#ACTION "If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the switch or interconnect. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert indicates a loss of connectivity between the network adapter and the switch or interconnect. Check the physical connection from the server to its destination device such as interconnect ,blade, switch etc, including any cables. Also check the configuration of the operating system and destination device."
                              
            ::= 18012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB

    Related source files and packages:


    Source location: CPQNIC-MIB::cpqNic3ConnectivityLost.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.096280+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.6081 cpqHeNvdimmEraseError00
1.3.6.1.4.1.232.0.6082 cpqHeNvdimmArmingError00
1.3.6.1.4.1.232.0.6083 cpqHeNvdimmSanitizationOk00
1.3.6.1.4.1.232.0.6084 cpqHeNvdimmSanitizationError00
1.3.6.1.4.1.232.0.6085 cpqHeNvdimmControllerFirmwareError00
1.3.6.1.4.1.232.0.6086 cpqHeNvdimmErrorInterleaveOn00
1.3.6.1.4.1.232.0.6087 cpqHeNvdimmInterleaveOff00
1.3.6.1.4.1.232.0.6088 cpqHeNvdimmEventNotifyError00
1.3.6.1.4.1.232.0.6089 cpqHeNvdimmPersistencyLost00
1.3.6.1.4.1.232.0.6090 cpqHeNvdimmPersistencyRestored00
1.3.6.1.4.1.232.0.6091 cpqHeNvdimmLifecycleWarning00
1.3.6.1.4.1.232.0.6092 cpqHeNvdimmLogicalNvdimmError00
1.3.6.1.4.1.232.0.6093 cpqHeNvdimmConfigurationError00
1.3.6.1.4.1.232.0.6094 cpqHeNvdimmBatteryNotChargedwithWait00
1.3.6.1.4.1.232.0.6095 cpqHeNvdimmBatteryNotChargedwithNoWait00
1.3.6.1.4.1.232.0.6096 cpqHeDimmMemoryMapChanged00
1.3.6.1.4.1.232.0.6097 cpqHeNvdimmPersistantMemoryAddressError00
1.3.6.1.4.1.232.0.6098 cpqHeNvdimmInitializationError00
1.3.6.1.4.1.232.0.6099 cpqHePwrSupplyError00
1.3.6.1.4.1.232.0.6100 cpqHePwrSupplyErrorRepaired00
1.3.6.1.4.1.232.0.6101 cpqHeBbuError00
1.3.6.1.4.1.232.0.6102 cpqHeBbuErrorRepaired00
1.3.6.1.4.1.232.0.6103 cpqHeNoPowerSupplyDetected00
1.3.6.1.4.1.232.0.6104 cpqHePowerProtectionFault00
1.3.6.1.4.1.232.0.6105 cpqHePowerFuseDegraded00
1.3.6.1.4.1.232.0.6106 cpqHeTPMSecureEraseFailed00
1.3.6.1.4.1.232.0.6107 cpqHeSPISecureEraseFailed00
1.3.6.1.4.1.232.0.6108 cpqHePMMSecureEraseFailed00
1.3.6.1.4.1.232.0.6109 cpqHeNANDSecureEraseFailed00
1.3.6.1.4.1.232.0.6110 cpqHeSedPassphrasefail00
1.3.6.1.4.1.232.0.6111 cpqHeSedUnlockfail00
1.3.6.1.4.1.232.0.6112 cpqHePMMHealthFailure00
1.3.6.1.4.1.232.0.6113 cpqHePMMLessUsageRemainingAlert00
1.3.6.1.4.1.232.0.6114 cpqHePMMConfigErr00
1.3.6.1.4.1.232.0.6115 cpqHePMMShutdownWarning00
1.3.6.1.4.1.232.0.6116 cpqHePMMCorrErrThreshold00
1.3.6.1.4.1.232.0.6117 cpqHePMMBootStatusRegWarning00
1.3.6.1.4.1.232.0.6118 cpqHeInletAmbientPreCautionThresAlert00
1.3.6.1.4.1.232.0.6119 cpqHeCoolingModuleDegraded00
1.3.6.1.4.1.232.0.6120 cpqHeCoolingModuleFailed00
1.3.6.1.4.1.232.0.6121 cpqHeCoolingModuleRedundancyLost00
1.3.6.1.4.1.232.0.6122 cpqHeCoolingModuleRedundancyRestored00
1.3.6.1.4.1.232.0.8001 cpqSs2FanStatusChange00
1.3.6.1.4.1.232.0.8002 cpqSsTempFailed00
1.3.6.1.4.1.232.0.8003 cpqSsTempDegraded00
1.3.6.1.4.1.232.0.8004 cpqSsTempOk00
1.3.6.1.4.1.232.0.8005 cpqSsSidePanelInPlace00
1.3.6.1.4.1.232.0.8006 cpqSsSidePanelRemoved00
1.3.6.1.4.1.232.0.8007 cpqSsPwrSupplyDegraded00
1.3.6.1.4.1.232.0.8008 cpqSs3FanStatusChange00