Reference record for OID 1.3.6.1.4.1.232.0.18012

Parent
1.3.6.1.4.1.232.0 (0)
Node code
18012
Node name
cpqNic3ConnectivityLost
Numeric OID
1.3.6.1.4.1.232.0.18012
URN notation
urn:oid:1.3.6.1.4.1.232.0.18012
ASN.1 notation

{1 3 6 1 4 1 232 0 18012}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic3ConnectivityLost(18012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic3ConnectivityLost(18012)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/18012
  • /ISO/Identified-Organization/6/1/4/1/232/0/18012
  • /ISO/3/6/1/4/1/232/0/18012
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqNic3ConnectivityLost
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqNic3ConnectivityLost
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqNic3ConnectivityLost
  • Additional combinations skipped.

Descriptions

cpqNic3ConnectivityLost — Circitor, MIBdepot

This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.

cpqNic3ConnectivityLost — HPE networking MIB copies (LibreNMS/Observium Community)

This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections.

Source records

cpqNic3ConnectivityLost

Status in source: unspecified.

Names: cpqNic3ConnectivityLost

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNic3ConnectivityLost",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    ",",
    "cpqSiServerSystemId",
    ",",
    "cpqNicIfPhysAdapterStatus",
    ",",
    "cpqSePciSlotBoardName",
    ",",
    "cpqNicIfPhysAdapterPartNumber",
    ",",
    "ipAdEntAddr",
    ",",
    "cpqNicIfLogMapIPV6Address",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.\"",
    "::=",
    "18012"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort",
        "cpqSiServerSystemId",
        "cpqNicIfPhysAdapterStatus",
        "cpqSePciSlotBoardName",
        "cpqNicIfPhysAdapterPartNumber",
        "ipAdEntAddr",
        "cpqNicIfLogMapIPV6Address"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic3ConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Connectivity Lost Trap (18012)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 18
                 --#STATE NONOPERATIONAL
            ::= 18012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC.MIB.txt
    Source location: CPQNIC-MIB::cpqNic3ConnectivityLost.
    Source version and references

    Archived: 2026-10-19T00:22:08.785287+00:00.

  • Preserved circitor archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic3ConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address }
            DESCRIPTION
                "This trap will be sent any time the status of a logical
                 adapter changes to the Failed condition.  This occurs
                 when the adapter in a single adapter configuration fails,
                 or when the last adapter in a redundant configuration fails.
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Connectivity Lost Trap (18012)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 18
                 --#STATE NONOPERATIONAL
            ::= 18012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB.mib
    Source location: CPQNIC-MIB::cpqNic3ConnectivityLost.
    Source version and references

    Archived: 2026-10-19T00:22:16.786453+00:00.

cpqNic3ConnectivityLost

Status in source: unspecified.

Names: cpqNic3ConnectivityLost

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNic3ConnectivityLost",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    ",",
    "cpqSiServerSystemId",
    ",",
    "cpqNicIfPhysAdapterStatus",
    ",",
    "cpqSePciSlotBoardName",
    ",",
    "cpqNicIfPhysAdapterPartNumber",
    ",",
    "ipAdEntAddr",
    ",",
    "cpqNicIfLogMapIPV6Address",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections.\"",
    "::=",
    "18012"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort",
        "cpqSiServerSystemId",
        "cpqNicIfPhysAdapterStatus",
        "cpqSePciSlotBoardName",
        "cpqNicIfPhysAdapterPartNumber",
        "ipAdEntAddr",
        "cpqNicIfLogMapIPV6Address"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQNIC-MIB

    Published definition
    cpqNic3ConnectivityLost TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address }
            DESCRIPTION
                "This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections."
    
                 --#TYPE "NIC Connectivity Lost Trap (18012)"
                 --#SUMMARY "Connectivity lost for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 18
                 --#STATE NONOPERATIONAL
                 --#SIMPLE_SEVERITY MAJOR
                 --#HWSTATUS_CATEGORY NETWORK
                 --#ACTION "If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the switch or interconnect. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert indicates a loss of connectivity between the network adapter and the switch or interconnect. Check the physical connection from the server to its destination device such as interconnect ,blade, switch etc, including any cables. Also check the configuration of the operating system and destination device."
                              
            ::= 18012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB

    Related source files and packages:


    Source location: CPQNIC-MIB::cpqNic3ConnectivityLost.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.096280+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.9026 cpqSm2FwUpdateUploadFailed00
1.3.6.1.4.1.232.0.9027 cpqSm2SecurityStateChange00
1.3.6.1.4.1.232.0.9028 cpqSm2WDTimerReset00
1.3.6.1.4.1.232.0.9029 cpqSm2OverallSecStateAtRisk00
1.3.6.1.4.1.232.0.9030 cpqSm2OverallSecStatusChange00
1.3.6.1.4.1.232.0.10001 cpqMeRisingAlarm00
1.3.6.1.4.1.232.0.10002 cpqMeFallingAlarm00
1.3.6.1.4.1.232.0.10003 cpqMe2RisingAlarm00
1.3.6.1.4.1.232.0.10004 cpqMe2FallingAlarm00
1.3.6.1.4.1.232.0.10005 cpqMeRisingAlarmExtended00
1.3.6.1.4.1.232.0.10006 cpqMeFallingAlarmExtended00
1.3.6.1.4.1.232.0.10007 cpqMeCriticalRisingAlarmExtended00
1.3.6.1.4.1.232.0.10008 cpqMeCriticalFallingAlarmExtended00
1.3.6.1.4.1.232.0.11001 cpqHoGenericTrap00
1.3.6.1.4.1.232.0.11002 cpqHoAppErrorTrap00
1.3.6.1.4.1.232.0.11003 cpqHo2GenericTrap00
1.3.6.1.4.1.232.0.11004 cpqHo2AppErrorTrap00
1.3.6.1.4.1.232.0.11005 cpqHo2NicStatusOk00
1.3.6.1.4.1.232.0.11006 cpqHo2NicStatusFailed00
1.3.6.1.4.1.232.0.11007 cpqHo2NicSwitchoverOccurred00
1.3.6.1.4.1.232.0.11008 cpqHo2NicStatusOk200
1.3.6.1.4.1.232.0.11009 cpqHo2NicStatusFailed200
1.3.6.1.4.1.232.0.11010 cpqHo2NicSwitchoverOccurred200
1.3.6.1.4.1.232.0.11011 cpqHoProcessEventTrap00
1.3.6.1.4.1.232.0.11012 cpqHoProcessCountWarning00
1.3.6.1.4.1.232.0.11013 cpqHoProcessCountNormal00
1.3.6.1.4.1.232.0.11014 cpqHoCriticalSoftwareUpdateTrap00
1.3.6.1.4.1.232.0.11015 cpqHoCrashDumpNotEnabledTrap00
1.3.6.1.4.1.232.0.11016 cpqHoBootPagingFileTooSmallTrap00
1.3.6.1.4.1.232.0.11017 cpqHoSWRunningStatusChangeTrap00
1.3.6.1.4.1.232.0.11018 cpqHo2PowerThresholdTrap00
1.3.6.1.4.1.232.0.11019 cpqHoBootPagingFileOrFreeSpaceTooSmallTrap00
1.3.6.1.4.1.232.0.11020 cpqHoMibHealthStatusArrayChangeTrap00
1.3.6.1.4.1.232.0.12001 cpqUpsLineFailed00
1.3.6.1.4.1.232.0.12002 cpqUpsLineOk00
1.3.6.1.4.1.232.0.12003 cpqUpsShutdown00
1.3.6.1.4.1.232.0.12004 cpqUpsConfirmation00
1.3.6.1.4.1.232.0.12005 cpqUpsBatteryLow00
1.3.6.1.4.1.232.0.12006 cpqUps2LineFailed00
1.3.6.1.4.1.232.0.12007 cpqUps2LineOk00
1.3.6.1.4.1.232.0.12008 cpqUps2Shutdown00
1.3.6.1.4.1.232.0.12009 cpqUps2Confirmation00
1.3.6.1.4.1.232.0.12010 cpqUps2BatteryLow00
1.3.6.1.4.1.232.0.12011 cpqUpsOverload00
1.3.6.1.4.1.232.0.12012 cpqUpsPendingBatteryFailure00
1.3.6.1.4.1.232.0.12013 cpqUpsGenericCritical00
1.3.6.1.4.1.232.0.12014 cpqUpsGenericInfo00
1.3.6.1.4.1.232.0.13001 cpqRsPartnerFailed00
1.3.6.1.4.1.232.0.13002 cpqRsStandbyCableFailure00
1.3.6.1.4.1.232.0.13003 cpqRsStandbyFailure00