Reference record for OID 1.3.6.1.4.1.232.0.18014

Parent
1.3.6.1.4.1.232.0 (0)
Node code
18014
Node name
cpqNic3RedundancyReduced
Numeric OID
1.3.6.1.4.1.232.0.18014
URN notation
urn:oid:1.3.6.1.4.1.232.0.18014
ASN.1 notation

{1 3 6 1 4 1 232 0 18014}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic3RedundancyReduced(18014)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic3RedundancyReduced(18014)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/18014
  • /ISO/Identified-Organization/6/1/4/1/232/0/18014
  • /ISO/3/6/1/4/1/232/0/18014
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqNic3RedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqNic3RedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqNic3RedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqNic3RedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqNic3RedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqNic3RedundancyReduced
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqNic3RedundancyReduced
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqNic3RedundancyReduced
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqNic3RedundancyReduced
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqNic3RedundancyReduced
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqNic3RedundancyReduced
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqNic3RedundancyReduced
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqNic3RedundancyReduced
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqNic3RedundancyReduced
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqNic3RedundancyReduced
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqNic3RedundancyReduced
  • Additional combinations skipped.

Descriptions

cpqNic3RedundancyReduced — HPE networking MIB copies (LibreNMS/Observium Community)

This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement.

cpqNic3RedundancyReduced — Circitor, MIBdepot

This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.

Source records

cpqNic3RedundancyReduced

Status in source: unspecified.

Names: cpqNic3RedundancyReduced

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNic3RedundancyReduced",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    ",",
    "cpqSiServerSystemId",
    ",",
    "cpqNicIfPhysAdapterStatus",
    ",",
    "cpqSePciSlotBoardName",
    ",",
    "cpqNicIfPhysAdapterPartNumber",
    ",",
    "ipAdEntAddr",
    ",",
    "cpqNicIfLogMapIPV6Address",
    ",",
    "cpqNicIfLogMapAdapterOKCount",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement.\"",
    "::=",
    "18014"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort",
        "cpqSiServerSystemId",
        "cpqNicIfPhysAdapterStatus",
        "cpqSePciSlotBoardName",
        "cpqNicIfPhysAdapterPartNumber",
        "ipAdEntAddr",
        "cpqNicIfLogMapIPV6Address",
        "cpqNicIfLogMapAdapterOKCount"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQNIC-MIB

    Published definition
    cpqNic3RedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address,
                        cpqNicIfLogMapAdapterOKCount }
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement."
    
                 --#TYPE "NIC Redundancy Reduced Trap (18014)"
                 --#SUMMARY "There is a loss in network adaptor redundancy because the link to the adapter at slot %d, port %d is down."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
                 --#SIMPLE_SEVERITY MAJOR
                 --#HWSTATUS_CATEGORY NETWORK
                 --#ACTION "Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement."
                              
            ::= 18014
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB

    Related source files and packages:


    Source location: CPQNIC-MIB::cpqNic3RedundancyReduced.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.096280+00:00.

cpqNic3RedundancyReduced

Status in source: unspecified.

Names: cpqNic3RedundancyReduced

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNic3RedundancyReduced",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    ",",
    "cpqSiServerSystemId",
    ",",
    "cpqNicIfPhysAdapterStatus",
    ",",
    "cpqSePciSlotBoardName",
    ",",
    "cpqNicIfPhysAdapterPartNumber",
    ",",
    "ipAdEntAddr",
    ",",
    "cpqNicIfLogMapIPV6Address",
    ",",
    "cpqNicIfLogMapAdapterOKCount",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.\"",
    "::=",
    "18014"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort",
        "cpqSiServerSystemId",
        "cpqNicIfPhysAdapterStatus",
        "cpqSePciSlotBoardName",
        "cpqNicIfPhysAdapterPartNumber",
        "ipAdEntAddr",
        "cpqNicIfLogMapIPV6Address",
        "cpqNicIfLogMapAdapterOKCount"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic3RedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address,
                        cpqNicIfLogMapAdapterOKCount }
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Redundancy Reduced Trap (18014)"
                 --#SUMMARY "Redundancy decreased by adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
            ::= 18014
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC.MIB.txt
    Source location: CPQNIC-MIB::cpqNic3RedundancyReduced.
    Source version and references

    Archived: 2026-10-19T00:22:08.785287+00:00.

  • Preserved circitor archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic3RedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr, cpqNicIfLogMapIPV6Address,
                        cpqNicIfLogMapAdapterOKCount }
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Redundancy Reduced Trap (18014)"
                 --#SUMMARY "Redundancy decreased by adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
            ::= 18014
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB.mib
    Source location: CPQNIC-MIB::cpqNic3RedundancyReduced.
    Source version and references

    Archived: 2026-10-19T00:22:16.786453+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.13603182 sCellEventTrap-0c-6e00
1.3.6.1.4.1.232.0.13603183 sCellEventTrap-0c-6f00
1.3.6.1.4.1.232.0.13603184 sCellEventTrap-0c-7000
1.3.6.1.4.1.232.0.13603185 sCellEventTrap-0c-7100
1.3.6.1.4.1.232.0.13603186 sCellEventTrap-0c-7200
1.3.6.1.4.1.232.0.13603187 sCellEventTrap-0c-7300
1.3.6.1.4.1.232.0.13603188 sCellEventTrap-0c-7400
1.3.6.1.4.1.232.0.13603189 sCellEventTrap-0c-7500
1.3.6.1.4.1.232.0.13603190 sCellEventTrap-0c-7600
1.3.6.1.4.1.232.0.13603191 sCellEventTrap-0c-7700
1.3.6.1.4.1.232.0.13603192 sCellEventTrap-0c-7800
1.3.6.1.4.1.232.0.13603193 sCellEventTrap-0c-7900
1.3.6.1.4.1.232.0.13603194 sCellEventTrap-0c-7a00
1.3.6.1.4.1.232.0.13603195 sCellEventTrap-0c-7b00
1.3.6.1.4.1.232.0.13603196 sCellEventTrap-0c-7c00
1.3.6.1.4.1.232.0.13603197 sCellEventTrap-0c-7d00
1.3.6.1.4.1.232.0.13603198 sCellEventTrap-0c-7e00
1.3.6.1.4.1.232.0.13603199 sCellEventTrap-0c-7f00
1.3.6.1.4.1.232.0.13603200 sCellEventTrap-0c-8000
1.3.6.1.4.1.232.0.13603201 sCellEventTrap-0c-8100
1.3.6.1.4.1.232.0.13603203 sCellEventTrap-0c-8300
1.3.6.1.4.1.232.0.13603204 sCellEventTrap-0c-8400
1.3.6.1.4.1.232.0.13603205 sCellEventTrap-0c-8500
1.3.6.1.4.1.232.0.13603206 sCellEventTrap-0c-8600
1.3.6.1.4.1.232.0.13603207 sCellEventTrap-0c-8700
1.3.6.1.4.1.232.0.13603208 sCellEventTrap-0c-8800
1.3.6.1.4.1.232.0.13603210 sCellEventTrap-0c-8a00
1.3.6.1.4.1.232.0.13603211 sCellEventTrap-0c-8b00
1.3.6.1.4.1.232.0.13603212 sCellEventTrap-0c-8c00
1.3.6.1.4.1.232.0.13603213 sCellEventTrap-0c-8d00
1.3.6.1.4.1.232.0.13603214 sCellEventTrap-0c-8e00
1.3.6.1.4.1.232.0.13603328 sCellEventTrap_d_0, sCellEventTrap-0d-0000
1.3.6.1.4.1.232.0.13603329 sCellEventTrap_d_1, sCellEventTrap-0d-0100
1.3.6.1.4.1.232.0.13603330 sCellEventTrap_d_2, sCellEventTrap-0d-0200
1.3.6.1.4.1.232.0.13603331 sCellEventTrap_d_3, sCellEventTrap-0d-0300
1.3.6.1.4.1.232.0.13603332 sCellEventTrap_d_4, sCellEventTrap-0d-0400
1.3.6.1.4.1.232.0.13603379 sCellEventTrap_d_33, sCellEventTrap-0d-3300
1.3.6.1.4.1.232.0.13603380 sCellEventTrap_d_34, sCellEventTrap-0d-3400
1.3.6.1.4.1.232.0.13603381 sCellEventTrap_d_35, sCellEventTrap-0d-3500
1.3.6.1.4.1.232.0.13603399 sCellEventTrap_d_47, sCellEventTrap-0d-4700
1.3.6.1.4.1.232.0.13603403 sCellEventTrap_d_4b, sCellEventTrap-0d-4b00
1.3.6.1.4.1.232.0.13603404 sCellEventTrap_d_4c, sCellEventTrap-0d-4c00
1.3.6.1.4.1.232.0.13603419 sCellEventTrap_d_5b, sCellEventTrap-0d-5b00
1.3.6.1.4.1.232.0.13603423 sCellEventTrap_d_5f, sCellEventTrap-0d-5f00
1.3.6.1.4.1.232.0.13603439 sCellEventTrap_d_6f, sCellEventTrap-0d-6f00
1.3.6.1.4.1.232.0.13603441 sCellEventTrap_d_71, sCellEventTrap-0d-7100
1.3.6.1.4.1.232.0.13603442 sCellEventTrap_d_72, sCellEventTrap-0d-7200
1.3.6.1.4.1.232.0.13603454 sCellEventTrap_d_7e, sCellEventTrap-0d-7e00
1.3.6.1.4.1.232.0.13603455 sCellEventTrap_d_7f, sCellEventTrap-0d-7f00
1.3.6.1.4.1.232.0.13603458 sCellEventTrap_d_82, sCellEventTrap-0d-8200