Reference record for OID 1.3.6.1.4.1.232.0.2003

Parent
1.3.6.1.4.1.232.0 (0)
Node code
2003
Node name
cpqSiMonitorConditionDegraded
Numeric OID
1.3.6.1.4.1.232.0.2003
URN notation
urn:oid:1.3.6.1.4.1.232.0.2003
ASN.1 notation

{1 3 6 1 4 1 232 0 2003}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/2003
  • /ISO/Identified-Organization/6/1/4/1/232/0/2003
  • /ISO/3/6/1/4/1/232/0/2003
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqSiMonitorConditionDegraded
  • Additional combinations skipped.

Descriptions

cpqSiMonitorConditionDegraded — HPE networking MIB copies (LibreNMS/Observium Community)

A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor`s condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.

cpqSiMonitorConditionDegraded — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot, Netdisco MIB archive copies

A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor's condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.

Source records

cpqSiMonitorConditionDegraded

Status in source: unspecified.

Names: cpqSiMonitorConditionDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSiMonitorConditionDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSiMonitorIndex",
    "}",
    "DESCRIPTION",
    "\"A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor`s condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.\"",
    "::=",
    "2003"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSiMonitorIndex"
      ]
    ],
    [
      "DESCRIPTION",
      "A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor`s condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor`s
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY NONE
            
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.571295+00:00.

cpqSiMonitorConditionDegraded

Status in source: unspecified.

Names: cpqSiMonitorConditionDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSiMonitorConditionDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSiMonitorIndex",
    "}",
    "DESCRIPTION",
    "\"A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor's condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.\"",
    "::=",
    "2003"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSiMonitorIndex"
      ]
    ],
    [
      "DESCRIPTION",
      "A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor's condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded"
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:07.813556+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.790070+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded"
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO1.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.790683+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE 
            ENTERPRISE compaq 
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex } 
            DESCRIPTION 
                "A fault reporting feature has exceeded normal limits for 
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's 
                 condition is degraded due to the internal temperature exceeding 
                 normal operating limits.  The monitor is still useable, but 
                 action should be taken to return the condition to OK. 
     
                 User Action: Physically check for obstructions to air flow around 
                 the monitor.  Check the thermostat in the room that the system 
                 occupies.  Allow the monitor to cool by turning off the monitor 
                 for 5 minutes then turn the monitor back on.  After the monitor 
                 cools, another alarm indicating an improving condition, such as 
                 Monitor OK, will be issued." 
     
            --#TYPE "Monitor Condition Degraded" 
            --#SUMMARY "The monitor's condition has been set to degraded." 
            --#ARGUMENTS {} 
            --#SEVERITY MINOR 
            --#TIMEINDEX 99 
            --#STATE DEGRADED 
     
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Compaq-SystemInfo.mib.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.811572+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded"
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqinfo.mib.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.862019+00:00.

  • Preserved circitor archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB.mib
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:16.800171+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQSINFO-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY NONE
            
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.145420+00:00.

  • Netdisco MIB archive copies · Publisher's source file: cpqsinfo-mib.mib

    Vendor MIB copy from the Netdisco archive.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqsinfo-mib.mib

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Downloaded: 2026-10-24T15:28:10.392995+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.1001 cpqSeCpuThresholdPassed00
1.3.6.1.4.1.232.0.1002 cpqSePCCardThermalDegraded00
1.3.6.1.4.1.232.0.1003 cpqSePCCardThermalFailure00
1.3.6.1.4.1.232.0.1004 cpqSePCCardThermalSafe00
1.3.6.1.4.1.232.0.1005 cpqSe2CpuThresholdPassed00
1.3.6.1.4.1.232.0.1006 cpqSeCpuStatusChange00
1.3.6.1.4.1.232.0.1007 cpqSeCpuPowerPodstatusChange00
1.3.6.1.4.1.232.0.1008 cpqSeUSBStorageDeviceAttached00
1.3.6.1.4.1.232.0.1009 cpqSeUSBStorageDeviceRemoved00
1.3.6.1.4.1.232.0.1010 cpqSeUSBStorageDeviceReadErrorOccurred00
1.3.6.1.4.1.232.0.1011 cpqSeUSBStorageDeviceWriteErrorOccurred00
1.3.6.1.4.1.232.0.1012 cpqSeUSBStorageDeviceRedundancyLost00
1.3.6.1.4.1.232.0.1013 cpqSeUSBStorageDeviceRedundancyRestored00
1.3.6.1.4.1.232.0.1014 cpqSeUSBStorageDeviceSyncFailed00
1.3.6.1.4.1.232.0.1015 cpqSePCIeDiskTemperatureFailed00
1.3.6.1.4.1.232.0.1016 cpqSePCIeDiskTemperatureOk00
1.3.6.1.4.1.232.0.1017 cpqSePCIeDiskConditionChange00
1.3.6.1.4.1.232.0.1018 cpqSePCIeDiskWearStatusChange00
1.3.6.1.4.1.232.0.1019 cpqSePciDeviceAddedOrPoweredOn00
1.3.6.1.4.1.232.0.1020 cpqSePciDeviceRemovedOrPoweredOff00
1.3.6.1.4.1.232.0.1021 cpqSeNVMeSecureEraseFailed00
1.3.6.1.4.1.232.0.1022 cpqSePcieTrainingFailed00
1.3.6.1.4.1.232.0.1023 cpqSePciResetFail00
1.3.6.1.4.1.232.0.1024 cpqSeSecureBootAuthFail00
1.3.6.1.4.1.232.0.1025 cpqSeSecureBootCertAuthFail00
1.3.6.1.4.1.232.0.1026 cpqSeCpuUncorrectableError00
1.3.6.1.4.1.232.0.1027 cpqSeInternalCpuError00
1.3.6.1.4.1.232.0.2001 cpqSiHoodRemoved00
1.3.6.1.4.1.232.0.2002 cpqSiMonitorConditionOK00
1.3.6.1.4.1.232.0.2004 cpqSiMonitorConditionFailed00
1.3.6.1.4.1.232.0.2005 cpqSiCorrMemErrStatusDegraded00
1.3.6.1.4.1.232.0.2006 cpqSiCorrMemErrStatusOk00
1.3.6.1.4.1.232.0.2007 cpqSiMemConfigChange00
1.3.6.1.4.1.232.0.2008 cpqSiHotPlugSlotBoardRemoved00
1.3.6.1.4.1.232.0.2009 cpqSiHotPlugSlotBoardInserted00
1.3.6.1.4.1.232.0.2010 cpqSiHotPlugSlotPowerUpFailed00
1.3.6.1.4.1.232.0.2011 cpqSiSysBatteryFailure00
1.3.6.1.4.1.232.0.2012 cpqSiSysBatteryChargingDegraded00
1.3.6.1.4.1.232.0.2013 cpqSiSysBatteryCalibrationError00
1.3.6.1.4.1.232.0.2014 cpqSiIntrusionInstalled00
1.3.6.1.4.1.232.0.2015 cpqSiIntrusionRemoved00
1.3.6.1.4.1.232.0.2016 cpqSiHoodReplaced00
1.3.6.1.4.1.232.0.2017 cpqSiHoodRemovedOnPowerOff00
1.3.6.1.4.1.232.0.2018 cpqSiSysTelemetryThresholdAlert00
1.3.6.1.4.1.232.0.3001 cpqDa2LogDrvStatusChange00
1.3.6.1.4.1.232.0.3002 cpqDa2SpareStatusChange00
1.3.6.1.4.1.232.0.3003 cpqDa2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3004 cpqDa2PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3005 cpqDa2AccelStatusChange00
1.3.6.1.4.1.232.0.3006 cpqDa2AccelBadDataTrap00