Reference record for OID 1.3.6.1.4.1.232.0.2003

Parent
1.3.6.1.4.1.232.0 (0)
Node code
2003
Node name
cpqSiMonitorConditionDegraded
Numeric OID
1.3.6.1.4.1.232.0.2003
URN notation
urn:oid:1.3.6.1.4.1.232.0.2003
ASN.1 notation

{1 3 6 1 4 1 232 0 2003}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/2003
  • /ISO/Identified-Organization/6/1/4/1/232/0/2003
  • /ISO/3/6/1/4/1/232/0/2003
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqSiMonitorConditionDegraded
  • Additional combinations skipped.

Descriptions

cpqSiMonitorConditionDegraded — HPE networking MIB copies (LibreNMS/Observium Community)

A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor`s condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.

cpqSiMonitorConditionDegraded — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot, Netdisco MIB archive copies

A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor's condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.

Source records

cpqSiMonitorConditionDegraded

Status in source: unspecified.

Names: cpqSiMonitorConditionDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSiMonitorConditionDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSiMonitorIndex",
    "}",
    "DESCRIPTION",
    "\"A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor`s condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.\"",
    "::=",
    "2003"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSiMonitorIndex"
      ]
    ],
    [
      "DESCRIPTION",
      "A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor`s condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor`s
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY NONE
            
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.571295+00:00.

cpqSiMonitorConditionDegraded

Status in source: unspecified.

Names: cpqSiMonitorConditionDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSiMonitorConditionDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSiMonitorIndex",
    "}",
    "DESCRIPTION",
    "\"A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor's condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.\"",
    "::=",
    "2003"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSiMonitorIndex"
      ]
    ],
    [
      "DESCRIPTION",
      "A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor's condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded"
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:07.813556+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.790070+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded"
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO1.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.790683+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE 
            ENTERPRISE compaq 
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex } 
            DESCRIPTION 
                "A fault reporting feature has exceeded normal limits for 
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's 
                 condition is degraded due to the internal temperature exceeding 
                 normal operating limits.  The monitor is still useable, but 
                 action should be taken to return the condition to OK. 
     
                 User Action: Physically check for obstructions to air flow around 
                 the monitor.  Check the thermostat in the room that the system 
                 occupies.  Allow the monitor to cool by turning off the monitor 
                 for 5 minutes then turn the monitor back on.  After the monitor 
                 cools, another alarm indicating an improving condition, such as 
                 Monitor OK, will be issued." 
     
            --#TYPE "Monitor Condition Degraded" 
            --#SUMMARY "The monitor's condition has been set to degraded." 
            --#ARGUMENTS {} 
            --#SEVERITY MINOR 
            --#TIMEINDEX 99 
            --#STATE DEGRADED 
     
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Compaq-SystemInfo.mib.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.811572+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded"
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqinfo.mib.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.862019+00:00.

  • Preserved circitor archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB.mib
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:16.800171+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQSINFO-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY NONE
            
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.145420+00:00.

  • Netdisco MIB archive copies · Publisher's source file: cpqsinfo-mib.mib

    Vendor MIB copy from the Netdisco archive.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqsinfo-mib.mib

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Downloaded: 2026-10-24T15:28:10.392995+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.136020030 mngmtAgentTrap-2003000
1.3.6.1.4.1.232.0.136020032 mngmtAgentTrap-2003200
1.3.6.1.4.1.232.0.136020033 mngmtAgentTrap-2003300
1.3.6.1.4.1.232.0.136020034 mngmtAgentTrap-2003400
1.3.6.1.4.1.232.0.136020035 mngmtAgentTrap-2003500
1.3.6.1.4.1.232.0.136020036 mngmtAgentTrap-2003600
1.3.6.1.4.1.232.0.136020038 mngmtAgentTrap-2003800
1.3.6.1.4.1.232.0.136020039 mngmtAgentTrap-2003900
1.3.6.1.4.1.232.0.136020040 mngmtAgentTrap-2004000
1.3.6.1.4.1.232.0.136020041 mngmtAgentTrap-2004100
1.3.6.1.4.1.232.0.136020042 mngmtAgentTrap-2004200
1.3.6.1.4.1.232.0.136020043 mngmtAgentTrap-2004300
1.3.6.1.4.1.232.0.136020044 mngmtAgentTrap-2004400
1.3.6.1.4.1.232.0.136020045 mngmtAgentTrap-2004500
1.3.6.1.4.1.232.0.136020046 mngmtAgentTrap-2004600
1.3.6.1.4.1.232.0.136020049 mngmtAgentTrap-2004900
1.3.6.1.4.1.232.0.136020050 mngmtAgentTrap-2005000
1.3.6.1.4.1.232.0.136020051 mngmtAgentTrap-2005100
1.3.6.1.4.1.232.0.136020052 mngmtAgentTrap-2005200
1.3.6.1.4.1.232.0.136021001 mngmtAgentTrap_21001, mngmtAgentTrap-2100100
1.3.6.1.4.1.232.0.136021002 mngmtAgentTrap_21002, mngmtAgentTrap-2100200
1.3.6.1.4.1.232.0.136021003 mngmtAgentTrap_21003, mngmtAgentTrap-2100300
1.3.6.1.4.1.232.0.136021004 mngmtAgentTrap_21004, mngmtAgentTrap-2100400
1.3.6.1.4.1.232.0.136021006 mngmtAgentTrap_21006, mngmtAgentTrap-2100600
1.3.6.1.4.1.232.0.136021007 mngmtAgentTrap_21007, mngmtAgentTrap-2100700
1.3.6.1.4.1.232.0.136021008 mngmtAgentTrap_21008, mngmtAgentTrap-2100800
1.3.6.1.4.1.232.0.136021009 mngmtAgentTrap_21009, mngmtAgentTrap-2100900
1.3.6.1.4.1.232.0.136021010 mngmtAgentTrap_21010, mngmtAgentTrap-2101000
1.3.6.1.4.1.232.0.136021011 mngmtAgentTrap_21011, mngmtAgentTrap-2101100
1.3.6.1.4.1.232.0.136021012 mngmtAgentTrap_21012, mngmtAgentTrap-2101200
1.3.6.1.4.1.232.0.136021013 mngmtAgentTrap_21013, mngmtAgentTrap-2101300
1.3.6.1.4.1.232.0.136021014 mngmtAgentTrap_21014, mngmtAgentTrap-2101400
1.3.6.1.4.1.232.0.136021015 mngmtAgentTrap_21015, mngmtAgentTrap-2101500
1.3.6.1.4.1.232.0.136021016 mngmtAgentTrap_21016, mngmtAgentTrap-2101600
1.3.6.1.4.1.232.0.136021017 mngmtAgentTrap_21017, mngmtAgentTrap-2101700
1.3.6.1.4.1.232.0.136021018 mngmtAgentTrap_21018, mngmtAgentTrap-2101800
1.3.6.1.4.1.232.0.136021019 mngmtAgentTrap_21019, mngmtAgentTrap-2101900
1.3.6.1.4.1.232.0.136021020 mngmtAgentTrap-2102000
1.3.6.1.4.1.232.0.136021021 mngmtAgentTrap-2102100
1.3.6.1.4.1.232.0.136021022 mngmtAgentTrap-2102200
1.3.6.1.4.1.232.0.136021023 mngmtAgentTrap-2102300
1.3.6.1.4.1.232.0.136021024 mngmtAgentTrap-2102400
1.3.6.1.4.1.232.0.136022001 mngmtAgentTrap_22001, mngmtAgentTrap-2200100
1.3.6.1.4.1.232.0.136022002 mngmtAgentTrap_22002, mngmtAgentTrap-2200200
1.3.6.1.4.1.232.0.136023002 mngmtAgentTrap_23002, mngmtAgentTrap-2300200
1.3.6.1.4.1.232.0.136023003 mngmtAgentTrap_23003, mngmtAgentTrap-2300300
1.3.6.1.4.1.232.0.136024001 mngmtAgentTrap_24001, mngmtAgentTrap-2400100
1.3.6.1.4.1.232.0.136024002 mngmtAgentTrap_24002, mngmtAgentTrap-2400200
1.3.6.1.4.1.232.0.136024003 mngmtAgentTrap_24003, mngmtAgentTrap-2400300
1.3.6.1.4.1.232.0.136024004 mngmtAgentTrap_24004, mngmtAgentTrap-2400400