Reference record for OID 1.3.6.1.4.1.232.0.2003

Parent
1.3.6.1.4.1.232.0 (0)
Node code
2003
Node name
cpqSiMonitorConditionDegraded
Numeric OID
1.3.6.1.4.1.232.0.2003
URN notation
urn:oid:1.3.6.1.4.1.232.0.2003
ASN.1 notation

{1 3 6 1 4 1 232 0 2003}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSiMonitorConditionDegraded(2003)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/2003
  • /ISO/Identified-Organization/6/1/4/1/232/0/2003
  • /ISO/3/6/1/4/1/232/0/2003
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqSiMonitorConditionDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqSiMonitorConditionDegraded
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqSiMonitorConditionDegraded
  • Additional combinations skipped.

Descriptions

cpqSiMonitorConditionDegraded — HPE networking MIB copies (LibreNMS/Observium Community)

A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor`s condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.

cpqSiMonitorConditionDegraded — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot, Netdisco MIB archive copies

A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor's condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.

Source records

cpqSiMonitorConditionDegraded

Status in source: unspecified.

Names: cpqSiMonitorConditionDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSiMonitorConditionDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSiMonitorIndex",
    "}",
    "DESCRIPTION",
    "\"A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor`s condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.\"",
    "::=",
    "2003"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSiMonitorIndex"
      ]
    ],
    [
      "DESCRIPTION",
      "A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor`s condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor`s
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY NONE
            
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.571295+00:00.

cpqSiMonitorConditionDegraded

Status in source: unspecified.

Names: cpqSiMonitorConditionDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSiMonitorConditionDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSiMonitorIndex",
    "}",
    "DESCRIPTION",
    "\"A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor's condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.\"",
    "::=",
    "2003"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSiMonitorIndex"
      ]
    ],
    [
      "DESCRIPTION",
      "A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor's condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded"
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:07.813556+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.790070+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded"
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO1.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.790683+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE 
            ENTERPRISE compaq 
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex } 
            DESCRIPTION 
                "A fault reporting feature has exceeded normal limits for 
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's 
                 condition is degraded due to the internal temperature exceeding 
                 normal operating limits.  The monitor is still useable, but 
                 action should be taken to return the condition to OK. 
     
                 User Action: Physically check for obstructions to air flow around 
                 the monitor.  Check the thermostat in the room that the system 
                 occupies.  Allow the monitor to cool by turning off the monitor 
                 for 5 minutes then turn the monitor back on.  After the monitor 
                 cools, another alarm indicating an improving condition, such as 
                 Monitor OK, will be issued." 
     
            --#TYPE "Monitor Condition Degraded" 
            --#SUMMARY "The monitor's condition has been set to degraded." 
            --#ARGUMENTS {} 
            --#SEVERITY MINOR 
            --#TIMEINDEX 99 
            --#STATE DEGRADED 
     
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Compaq-SystemInfo.mib.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.811572+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded"
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqinfo.mib.txt
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.862019+00:00.

  • Preserved circitor archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB.mib
    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:16.800171+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQSINFO-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY NONE
            
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.145420+00:00.

  • Netdisco MIB archive copies · Publisher's source file: cpqsinfo-mib.mib

    Vendor MIB copy from the Netdisco archive.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiMonitorConditionDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
            DESCRIPTION
                "A fault reporting feature has exceeded normal limits for
                 the monitor indicated by the cpqSiMonitorIndex. The monitor's
                 condition is degraded due to the internal temperature exceeding
                 normal operating limits.  The monitor is still useable, but
                 action should be taken to return the condition to OK.
    
                 User Action: Physically check for obstructions to air flow around
                 the monitor.  Check the thermostat in the room that the system
                 occupies.  Allow the monitor to cool by turning off the monitor
                 for 5 minutes then turn the monitor back on.  After the monitor
                 cools, another alarm indicating an improving condition, such as
                 Monitor OK, will be issued."
    
            --#TYPE "Monitor Condition Degraded (2003)" 
            --#SUMMARY "The monitor's condition has been set to degraded."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
           ::=  2003
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqsinfo-mib.mib

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiMonitorConditionDegraded.
    Source version and references

    Downloaded: 2026-10-24T15:28:10.392995+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.8010 cpqSs3TempDegraded00
1.3.6.1.4.1.232.0.8011 cpqSs3TempOk00
1.3.6.1.4.1.232.0.8012 cpqSs3SidePanelInPlace00
1.3.6.1.4.1.232.0.8013 cpqSs3SidePanelRemoved00
1.3.6.1.4.1.232.0.8014 cpqSs3PwrSupplyDegraded00
1.3.6.1.4.1.232.0.8015 cpqSs4PwrSupplyDegraded00
1.3.6.1.4.1.232.0.8016 cpqSsExFanStatusChange00
1.3.6.1.4.1.232.0.8017 cpqSsExPowerSupplyStatusChange00
1.3.6.1.4.1.232.0.8018 cpqSsExPowerSupplyUpsStatusChange00
1.3.6.1.4.1.232.0.8019 cpqSsExTempSensorStatusChange00
1.3.6.1.4.1.232.0.8020 cpqSsEx2FanStatusChange00
1.3.6.1.4.1.232.0.8021 cpqSsEx2PowerSupplyStatusChange00
1.3.6.1.4.1.232.0.8022 cpqSsExBackplaneFanStatusChange00
1.3.6.1.4.1.232.0.8023 cpqSsExBackplaneTempStatusChange00
1.3.6.1.4.1.232.0.8024 cpqSsExBackplanePowerSupplyStatusChange00
1.3.6.1.4.1.232.0.8025 cpqSsExRecoveryServerStatusChange00
1.3.6.1.4.1.232.0.8026 cpqSs5FanStatusChange00
1.3.6.1.4.1.232.0.8027 cpqSs5TempStatusChange00
1.3.6.1.4.1.232.0.8028 cpqSs5PwrSupplyStatusChange00
1.3.6.1.4.1.232.0.8029 cpqSs6FanStatusChange00
1.3.6.1.4.1.232.0.8030 cpqSs6TempStatusChange00
1.3.6.1.4.1.232.0.8031 cpqSs6PwrSupplyStatusChange00
1.3.6.1.4.1.232.0.8032 cpqSsConnectionStatusChange00
1.3.6.1.4.1.232.0.8033 cpqSsGSIStatusChange00
1.3.6.1.4.1.232.0.9001 cpqSm2ServerReset00
1.3.6.1.4.1.232.0.9002 cpqSm2ServerPowerOutage00
1.3.6.1.4.1.232.0.9003 cpqSm2UnauthorizedLoginAttempts00
1.3.6.1.4.1.232.0.9004 cpqSm2BatteryFailed00
1.3.6.1.4.1.232.0.9005 cpqSm2SelfTestError00
1.3.6.1.4.1.232.0.9006 cpqSm2InterfaceError00
1.3.6.1.4.1.232.0.9007 cpqSm2BatteryDisconnected00
1.3.6.1.4.1.232.0.9008 cpqSm2KeyboardCableDisconnected00
1.3.6.1.4.1.232.0.9009 cpqSm2MouseCableDisconnected00
1.3.6.1.4.1.232.0.9010 cpqSm2ExternalPowerCableDisconnected00
1.3.6.1.4.1.232.0.9011 cpqSm2LogsFull00
1.3.6.1.4.1.232.0.9012 cpqSm2SecurityOverrideEngaged00
1.3.6.1.4.1.232.0.9013 cpqSm2SecurityOverrideDisengaged00
1.3.6.1.4.1.232.0.9014 cpqSm2ServerFatalError00
1.3.6.1.4.1.232.0.9015 cpqSm2NicLinkDown00
1.3.6.1.4.1.232.0.9016 cpqSm2NicLinkUp00
1.3.6.1.4.1.232.0.9017 cpqSm2ServerPowerOn00
1.3.6.1.4.1.232.0.9018 cpqSm2ServerPowerOff00
1.3.6.1.4.1.232.0.9019 cpqSm2ServerPowerOnFailure00
1.3.6.1.4.1.232.0.9020 cpqSm2IrsCommFailure00
1.3.6.1.4.1.232.0.9021 cpqSm2FirmwareValidationScanFailed00
1.3.6.1.4.1.232.0.9022 cpqSm2FirmwareValidationScanErrorRepaired00
1.3.6.1.4.1.232.0.9023 cpqSm2FirmwareValidationAutoRepairFailed00
1.3.6.1.4.1.232.0.9024 cpqSm2AutoShutdownInitiated00
1.3.6.1.4.1.232.0.9025 cpqSm2AutoShutdownCancelled00
1.3.6.1.4.1.232.0.9026 cpqSm2FwUpdateUploadFailed00