Reference record for OID 1.3.6.1.4.1.232.0.2012

Parent
1.3.6.1.4.1.232.0 (0)
Node code
2012
Node name
cpqSiSysBatteryChargingDegraded
Numeric OID
1.3.6.1.4.1.232.0.2012
URN notation
urn:oid:1.3.6.1.4.1.232.0.2012
ASN.1 notation

{1 3 6 1 4 1 232 0 2012}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSiSysBatteryChargingDegraded(2012)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/2012
  • /ISO/Identified-Organization/6/1/4/1/232/0/2012
  • /ISO/3/6/1/4/1/232/0/2012
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqSiSysBatteryChargingDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqSiSysBatteryChargingDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqSiSysBatteryChargingDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqSiSysBatteryChargingDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqSiSysBatteryChargingDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqSiSysBatteryChargingDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqSiSysBatteryChargingDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqSiSysBatteryChargingDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqSiSysBatteryChargingDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqSiSysBatteryChargingDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqSiSysBatteryChargingDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqSiSysBatteryChargingDegraded
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqSiSysBatteryChargingDegraded
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqSiSysBatteryChargingDegraded
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqSiSysBatteryChargingDegraded
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqSiSysBatteryChargingDegraded
  • Additional combinations skipped.

Descriptions

cpqSiSysBatteryChargingDegraded — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot, Netdisco MIB archive copies

Significant battery degradation has occurred with battery indicated by cpqSiSysBatteryIndex. The battery can no longer be fully recharged. User Action: If using multiple batteries, run the Power Conservation Utility to identify the battery location. Contact your System Administrator or Authorized Reseller to order a replacement battery.

cpqSiSysBatteryChargingDegraded — MIBdepot

Significant battery degradation has occurred with battery indicated by cpqSiSysBatteryIndex. The battery can no longer be fully recharged. User Action: If using multiple batteries, run Compaq Power Conservation Utility to identify the battery location. Contact your System Administrator or Compaq Authorized Reseller to order a replacement battery.

Source records

cpqSiSysBatteryChargingDegraded

Status in source: unspecified.

Names: cpqSiSysBatteryChargingDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSiSysBatteryChargingDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSiSysBatteryIndex",
    ",",
    "cpqSiSysBatterySerialNum",
    "}",
    "DESCRIPTION",
    "\"Significant battery degradation has occurred with battery indicated by cpqSiSysBatteryIndex. The battery can no longer be fully recharged. User Action: If using multiple batteries, run the Power Conservation Utility to identify the battery location. Contact your System Administrator or Authorized Reseller to order a replacement battery.\"",
    "::=",
    "2012"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSiSysBatteryIndex",
        "cpqSiSysBatterySerialNum"
      ]
    ],
    [
      "DESCRIPTION",
      "Significant battery degradation has occurred with battery indicated by cpqSiSysBatteryIndex. The battery can no longer be fully recharged. User Action: If using multiple batteries, run the Power Conservation Utility to identify the battery location. Contact your System Administrator or Authorized Reseller to order a replacement battery."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiSysBatteryChargingDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
                         cpqSiSysBatterySerialNum  }
            DESCRIPTION
                "Significant battery degradation has occurred with battery
                indicated by cpqSiSysBatteryIndex.  The battery can
                no longer be fully recharged.
    
                User Action: If using multiple batteries, run
                the Power Conservation Utility to identify the
                battery location.  Contact your System Administrator
                or Authorized Reseller to order a replacement
                battery."
    
            --#TYPE "Battery Charging Degradation (2012)"
            --#SUMMARY "Battery %d has degraded charging capacity."
            --#ARGUMENTS {2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 2012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiSysBatteryChargingDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.790070+00:00.

  • Preserved circitor archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiSysBatteryChargingDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
                         cpqSiSysBatterySerialNum  }
            DESCRIPTION
                "Significant battery degradation has occurred with battery
                indicated by cpqSiSysBatteryIndex.  The battery can
                no longer be fully recharged.
    
                User Action: If using multiple batteries, run
                the Power Conservation Utility to identify the
                battery location.  Contact your System Administrator
                or Authorized Reseller to order a replacement
                battery."
    
            --#TYPE "Battery Charging Degradation (2012)"
            --#SUMMARY "Battery %d has degraded charging capacity."
            --#ARGUMENTS {2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 2012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB.mib
    Source location: CPQSINFO-MIB::cpqSiSysBatteryChargingDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:16.800171+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQSINFO-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiSysBatteryChargingDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
                         cpqSiSysBatterySerialNum  }
            DESCRIPTION
                "Significant battery degradation has occurred with battery
                indicated by cpqSiSysBatteryIndex.  The battery can
                no longer be fully recharged.
    
                User Action: If using multiple batteries, run
                the Power Conservation Utility to identify the
                battery location.  Contact your System Administrator
                or Authorized Reseller to order a replacement
                battery."
    
            --#TYPE "Battery Charging Degradation (2012)"
            --#SUMMARY "Battery %d has degraded charging capacity."
            --#ARGUMENTS {2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY NONE        
            --#ACTION "Replace the failing battery."        
            ::= 2012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiSysBatteryChargingDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.145420+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiSysBatteryChargingDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
                         cpqSiSysBatterySerialNum  }
            DESCRIPTION
                "Significant battery degradation has occurred with battery
                indicated by cpqSiSysBatteryIndex.  The battery can
                no longer be fully recharged.
    
                User Action: If using multiple batteries, run
                the Power Conservation Utility to identify the
                battery location.  Contact your System Administrator
                or Authorized Reseller to order a replacement
                battery."
    
            --#TYPE "Battery Charging Degradation (2012)"
            --#SUMMARY "Battery %d has degraded charging capacity."
            --#ARGUMENTS {2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY NONE        
            --#ACTION "Replace the failing battery."        
            ::= 2012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO-MIB

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiSysBatteryChargingDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.571295+00:00.

  • Netdisco MIB archive copies · Publisher's source file: cpqsinfo-mib.mib

    Vendor MIB copy from the Netdisco archive.

    Module: CPQSINFO-MIB

    Published definition
    cpqSiSysBatteryChargingDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
                         cpqSiSysBatterySerialNum  }
            DESCRIPTION
                "Significant battery degradation has occurred with battery
                indicated by cpqSiSysBatteryIndex.  The battery can
                no longer be fully recharged.
    
                User Action: If using multiple batteries, run
                the Power Conservation Utility to identify the
                battery location.  Contact your System Administrator
                or Authorized Reseller to order a replacement
                battery."
    
            --#TYPE "Battery Charging Degradation (2012)"
            --#SUMMARY "Battery %d has degraded charging capacity."
            --#ARGUMENTS {2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 2012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqsinfo-mib.mib

    Related source files and packages:


    Source location: CPQSINFO-MIB::cpqSiSysBatteryChargingDegraded.
    Source version and references

    Downloaded: 2026-10-24T15:28:10.392995+00:00.

cpqSiSysBatteryChargingDegraded

Status in source: unspecified.

Names: cpqSiSysBatteryChargingDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSiSysBatteryChargingDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSiSysBatteryIndex",
    ",",
    "cpqSiSysBatterySerialNum",
    "}",
    "DESCRIPTION",
    "\"Significant battery degradation has occurred with battery indicated by cpqSiSysBatteryIndex. The battery can no longer be fully recharged. User Action: If using multiple batteries, run Compaq Power Conservation Utility to identify the battery location. Contact your System Administrator or Compaq Authorized Reseller to order a replacement battery.\"",
    "::=",
    "2012"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSiSysBatteryIndex",
        "cpqSiSysBatterySerialNum"
      ]
    ],
    [
      "DESCRIPTION",
      "Significant battery degradation has occurred with battery indicated by cpqSiSysBatteryIndex. The battery can no longer be fully recharged. User Action: If using multiple batteries, run Compaq Power Conservation Utility to identify the battery location. Contact your System Administrator or Compaq Authorized Reseller to order a replacement battery."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiSysBatteryChargingDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
                         cpqSiSysBatterySerialNum  }
            DESCRIPTION
                "Significant battery degradation has occurred with battery
                indicated by cpqSiSysBatteryIndex.  The battery can
                no longer be fully recharged.
    
                User Action: If using multiple batteries, run
                Compaq Power Conservation Utility to identify the
                battery location.  Contact your System Administrator
                or Compaq Authorized Reseller to order a replacement
                battery."
    
            --#TYPE "Battery Charging Degradation"
            --#SUMMARY "Battery %d has degraded charging capacity."
            --#ARGUMENTS {2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 2012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiSysBatteryChargingDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:07.813556+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiSysBatteryChargingDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
                         cpqSiSysBatterySerialNum  }
            DESCRIPTION
                "Significant battery degradation has occurred with battery
                indicated by cpqSiSysBatteryIndex.  The battery can
                no longer be fully recharged.
    
                User Action: If using multiple batteries, run
                Compaq Power Conservation Utility to identify the
                battery location.  Contact your System Administrator
                or Compaq Authorized Reseller to order a replacement
                battery."
    
            --#TYPE "Battery Charging Degradation"
            --#SUMMARY "Battery %d has degraded charging capacity."
            --#ARGUMENTS {2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            ::= 2012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSINFO1.MIB.txt
    Source location: CPQSINFO-MIB::cpqSiSysBatteryChargingDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.790683+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiSysBatteryChargingDegraded TRAP-TYPE 
            ENTERPRISE compaq 
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex, 
                         cpqSiSysBatterySerialNum  } 
            DESCRIPTION 
                "Significant battery degradation has occurred with battery 
                indicated by cpqSiSysBatteryIndex.  The battery can 
                no longer be fully recharged. 
     
                User Action: If using multiple batteries, run 
                Compaq Power Conservation Utility to identify the 
                battery location.  Contact your System Administrator 
                or Compaq Authorized Reseller to order a replacement 
                battery." 
     
            --#TYPE "Battery Charging Degradation" 
            --#SUMMARY "Battery %d has degraded charging capacity." 
            --#ARGUMENTS {2} 
            --#SEVERITY MAJOR 
            --#TIMEINDEX 99 
            --#STATE DEGRADED 
    -- :CPQ,DEV: 
    --     This trap should be generated when cpqSiSysBatteryStatus goes 
    --            from ok  to capacityDegraded. 
    -- 
    -- :CPQ,ENDDEV: 
            ::= 2012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Compaq-SystemInfo.mib.txt
    Source location: CPQSINFO-MIB::cpqSiSysBatteryChargingDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.811572+00:00.

  • Preserved mibdepot archive

    Module: CPQSINFO-MIB

    Published definition
    cpqSiSysBatteryChargingDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
                         cpqSiSysBatterySerialNum  }
            DESCRIPTION
                "Significant battery degradation has occurred with battery
                indicated by cpqSiSysBatteryIndex.  The battery can
                no longer be fully recharged.
    
                User Action: If using multiple batteries, run
                Compaq Power Conservation Utility to identify the
                battery location.  Contact your System Administrator
                or Compaq Authorized Reseller to order a replacement
                battery."
    
            --#TYPE "Battery Charging Degradation"
            --#SUMMARY "Battery %d has degraded charging capacity."
            --#ARGUMENTS {2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    -- :CPQ,DEV:
    --     This trap should be generated when cpqSiSysBatteryStatus goes
    --            from ok  to capacityDegraded.
    --
    -- :CPQ,ENDDEV:
            ::= 2012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqinfo.mib.txt
    Source location: CPQSINFO-MIB::cpqSiSysBatteryChargingDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.862019+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.18005 cpqNic2ConnectivityRestored00
1.3.6.1.4.1.232.0.18006 cpqNic2ConnectivityLost00
1.3.6.1.4.1.232.0.18007 cpqNic2RedundancyIncreased00
1.3.6.1.4.1.232.0.18008 cpqNic2RedundancyReduced00
1.3.6.1.4.1.232.0.18009 cpqNicVirusLikeActivityDetected00
1.3.6.1.4.1.232.0.18010 cpqNicVirusLikeActivityStopped00
1.3.6.1.4.1.232.0.18011 cpqNic3ConnectivityRestored00
1.3.6.1.4.1.232.0.18012 cpqNic3ConnectivityLost00
1.3.6.1.4.1.232.0.18013 cpqNic3RedundancyIncreased00
1.3.6.1.4.1.232.0.18014 cpqNic3RedundancyReduced00
1.3.6.1.4.1.232.0.18015 cpqNicAllLinksDown00
1.3.6.1.4.1.232.0.18016 cpqNicAllLinksDownRepaired00
1.3.6.1.4.1.232.0.18017 cpqNicFlexLomTrainingFailed00
1.3.6.1.4.1.232.0.19001 cpqOsCpuTimeDegraded00
1.3.6.1.4.1.232.0.19002 cpqOsCpuTimeFailed00
1.3.6.1.4.1.232.0.19003 cpqOsCacheCopyReadHitsDegraded00
1.3.6.1.4.1.232.0.19004 cpqOsCacheCopyReadHitsFailed00
1.3.6.1.4.1.232.0.19005 cpqOsPageFileUsageDegraded00
1.3.6.1.4.1.232.0.19006 cpqOsPageFileUsageFailed00
1.3.6.1.4.1.232.0.19007 cpqOsLogicalDiskBusyTimeDegraded00
1.3.6.1.4.1.232.0.19008 cpqOsLogicalDiskBusyTimeFailed00
1.3.6.1.4.1.232.0.22001 cpqRackNameChanged00
1.3.6.1.4.1.232.0.22002 cpqRackEnclosureNameChanged00
1.3.6.1.4.1.232.0.22003 cpqRackEnclosureRemoved00
1.3.6.1.4.1.232.0.22004 cpqRackEnclosureInserted00
1.3.6.1.4.1.232.0.22005 cpqRackEnclosureTempFailed00
1.3.6.1.4.1.232.0.22006 cpqRackEnclosureTempDegraded00
1.3.6.1.4.1.232.0.22007 cpqRackEnclosureTempOk00
1.3.6.1.4.1.232.0.22008 cpqRackEnclosureFanFailed00
1.3.6.1.4.1.232.0.22009 cpqRackEnclosureFanDegraded00
1.3.6.1.4.1.232.0.22010 cpqRackEnclosureFanOk00
1.3.6.1.4.1.232.0.22011 cpqRackEnclosureFanRemoved00
1.3.6.1.4.1.232.0.22012 cpqRackEnclosureFanInserted00
1.3.6.1.4.1.232.0.22013 cpqRackPowerSupplyFailed00
1.3.6.1.4.1.232.0.22014 cpqRackPowerSupplyDegraded00
1.3.6.1.4.1.232.0.22015 cpqRackPowerSupplyOk00
1.3.6.1.4.1.232.0.22016 cpqRackPowerSupplyRemoved00
1.3.6.1.4.1.232.0.22017 cpqRackPowerSupplyInserted00
1.3.6.1.4.1.232.0.22018 cpqRackPowerSubsystemNotRedundant00
1.3.6.1.4.1.232.0.22019 cpqRackPowerSubsystemLineVoltageProblem00
1.3.6.1.4.1.232.0.22020 cpqRackPowerSubsystemOverloadCondition00
1.3.6.1.4.1.232.0.22021 cpqRackPowerShedAutoShutdown00
1.3.6.1.4.1.232.0.22022 cpqRackServerPowerOnFailedNotRedundant00
1.3.6.1.4.1.232.0.22023 cpqRackServerPowerOnFailedNotEnoughPower00
1.3.6.1.4.1.232.0.22024 cpqRackServerPowerOnFailedEnclosureNotFound00
1.3.6.1.4.1.232.0.22025 cpqRackServerPowerOnFailedPowerChassisNotFound00
1.3.6.1.4.1.232.0.22026 cpqRackServerPowerOnManualOverride00
1.3.6.1.4.1.232.0.22027 cpqRackFuseOpen00
1.3.6.1.4.1.232.0.22028 cpqRackServerBladeRemoved00
1.3.6.1.4.1.232.0.22029 cpqRackServerBladeInserted00