Reference record for OID 1.3.6.1.4.1.232.0.22008

Parent
1.3.6.1.4.1.232.0 (0)
Node code
22008
Node name
cpqRackEnclosureFanFailed
Numeric OID
1.3.6.1.4.1.232.0.22008
URN notation
urn:oid:1.3.6.1.4.1.232.0.22008
ASN.1 notation

{1 3 6 1 4 1 232 0 22008}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqRackEnclosureFanFailed(22008)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqRackEnclosureFanFailed(22008)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/22008
  • /ISO/Identified-Organization/6/1/4/1/232/0/22008
  • /ISO/3/6/1/4/1/232/0/22008
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqRackEnclosureFanFailed
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqRackEnclosureFanFailed
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqRackEnclosureFanFailed
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqRackEnclosureFanFailed
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqRackEnclosureFanFailed
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqRackEnclosureFanFailed
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqRackEnclosureFanFailed
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqRackEnclosureFanFailed
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqRackEnclosureFanFailed
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqRackEnclosureFanFailed
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqRackEnclosureFanFailed
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqRackEnclosureFanFailed
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqRackEnclosureFanFailed
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqRackEnclosureFanFailed
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqRackEnclosureFanFailed
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqRackEnclosureFanFailed
  • Additional combinations skipped.

Descriptions

cpqRackEnclosureFanFailed — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

The enclosure fan status has been set to failed. This trap signifies that an enclosure fan has failed and no other fans in the redundant fan group are operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible.

Source records

cpqRackEnclosureFanFailed

Status in source: unspecified.

Names: cpqRackEnclosureFanFailed

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqRackEnclosureFanFailed",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqRackName",
    ",",
    "cpqRackUid",
    ",",
    "cpqRackCommonEnclosureName",
    ",",
    "cpqRackCommonEnclosureSerialNum",
    ",",
    "cpqRackCommonEnclosureFanLocation",
    ",",
    "cpqRackCommonEnclosureFanSparePartNumber",
    ",",
    "cpqRackCommonEnclosureTrapSequenceNum",
    "}",
    "DESCRIPTION",
    "\"The enclosure fan status has been set to failed. This trap signifies that an enclosure fan has failed and no other fans in the redundant fan group are operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible.\"",
    "::=",
    "22008"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqRackName",
        "cpqRackUid",
        "cpqRackCommonEnclosureName",
        "cpqRackCommonEnclosureSerialNum",
        "cpqRackCommonEnclosureFanLocation",
        "cpqRackCommonEnclosureFanSparePartNumber",
        "cpqRackCommonEnclosureTrapSequenceNum"
      ]
    ],
    [
      "DESCRIPTION",
      "The enclosure fan status has been set to failed. This trap signifies that an enclosure fan has failed and no other fans in the redundant fan group are operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureFanFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureFanLocation,
                         cpqRackCommonEnclosureFanSparePartNumber,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The enclosure fan status has been set to failed.
    
                This trap signifies that an enclosure fan has failed and
                no other fans in the redundant fan group are operating.
                This may result in overheating of the enclosure.
    
                User Action: Replace the fan as soon as possible."
    
            --#TYPE "Enclosure fan failed (22008)"
            --#SUMMARY "The enclosure %s fan in rack %s has been set to failed."
            --#ARGUMENTS {4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
    
            ::= 22008
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK.MIB.txt
    Source location: CPQRACK-MIB::cpqRackEnclosureFanFailed.
    Source version and references

    Archived: 2026-10-19T00:22:08.787249+00:00.

  • Preserved circitor archive

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureFanFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureFanLocation,
                         cpqRackCommonEnclosureFanSparePartNumber,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The enclosure fan status has been set to failed.
    
                This trap signifies that an enclosure fan has failed and
                no other fans in the redundant fan group are operating.
                This may result in overheating of the enclosure.
    
                User Action: Replace the fan as soon as possible."
    
            --#TYPE "Enclosure fan failed (22008)"
            --#SUMMARY "The enclosure %s fan in rack %s has been set to failed."
            --#ARGUMENTS {4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
    
            ::= 22008
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB.mib
    Source location: CPQRACK-MIB::cpqRackEnclosureFanFailed.
    Source version and references

    Archived: 2026-10-19T00:22:16.793075+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQRACK-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureFanFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureFanLocation,
                         cpqRackCommonEnclosureFanSparePartNumber,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The enclosure fan status has been set to failed.
    
                This trap signifies that an enclosure fan has failed and
                no other fans in the redundant fan group are operating.
                This may result in overheating of the enclosure.
    
                User Action: Replace the fan as soon as possible."
    
            --#TYPE "Enclosure fan failed (22008)"
            --#SUMMARY "The fan %s in enclosure %s in rack %s has been set to failed."
            --#ARGUMENTS {6, 4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY THERMAL
            --#ACTION "Replace the failed enclosure fan."
            
            ::= 22008
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoOsType', 'cpqHoVersion'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB

    Related source files and packages:


    Source location: CPQRACK-MIB::cpqRackEnclosureFanFailed.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.143420+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureFanFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureFanLocation,
                         cpqRackCommonEnclosureFanSparePartNumber,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The enclosure fan status has been set to failed.
    
                This trap signifies that an enclosure fan has failed and
                no other fans in the redundant fan group are operating.
                This may result in overheating of the enclosure.
    
                User Action: Replace the fan as soon as possible."
    
            --#TYPE "Enclosure fan failed (22008)"
            --#SUMMARY "The fan %s in enclosure %s in rack %s has been set to failed."
            --#ARGUMENTS {6, 4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY THERMAL
            --#ACTION "Replace the failed enclosure fan."
            
            ::= 22008
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoOsType', 'cpqHoVersion'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB

    Related source files and packages:


    Source location: CPQRACK-MIB::cpqRackEnclosureFanFailed.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.206277+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.18004 cpqNicRedundancyReduced00
1.3.6.1.4.1.232.0.18005 cpqNic2ConnectivityRestored00
1.3.6.1.4.1.232.0.18006 cpqNic2ConnectivityLost00
1.3.6.1.4.1.232.0.18007 cpqNic2RedundancyIncreased00
1.3.6.1.4.1.232.0.18008 cpqNic2RedundancyReduced00
1.3.6.1.4.1.232.0.18009 cpqNicVirusLikeActivityDetected00
1.3.6.1.4.1.232.0.18010 cpqNicVirusLikeActivityStopped00
1.3.6.1.4.1.232.0.18011 cpqNic3ConnectivityRestored00
1.3.6.1.4.1.232.0.18012 cpqNic3ConnectivityLost00
1.3.6.1.4.1.232.0.18013 cpqNic3RedundancyIncreased00
1.3.6.1.4.1.232.0.18014 cpqNic3RedundancyReduced00
1.3.6.1.4.1.232.0.18015 cpqNicAllLinksDown00
1.3.6.1.4.1.232.0.18016 cpqNicAllLinksDownRepaired00
1.3.6.1.4.1.232.0.18017 cpqNicFlexLomTrainingFailed00
1.3.6.1.4.1.232.0.19001 cpqOsCpuTimeDegraded00
1.3.6.1.4.1.232.0.19002 cpqOsCpuTimeFailed00
1.3.6.1.4.1.232.0.19003 cpqOsCacheCopyReadHitsDegraded00
1.3.6.1.4.1.232.0.19004 cpqOsCacheCopyReadHitsFailed00
1.3.6.1.4.1.232.0.19005 cpqOsPageFileUsageDegraded00
1.3.6.1.4.1.232.0.19006 cpqOsPageFileUsageFailed00
1.3.6.1.4.1.232.0.19007 cpqOsLogicalDiskBusyTimeDegraded00
1.3.6.1.4.1.232.0.19008 cpqOsLogicalDiskBusyTimeFailed00
1.3.6.1.4.1.232.0.22001 cpqRackNameChanged00
1.3.6.1.4.1.232.0.22002 cpqRackEnclosureNameChanged00
1.3.6.1.4.1.232.0.22003 cpqRackEnclosureRemoved00
1.3.6.1.4.1.232.0.22004 cpqRackEnclosureInserted00
1.3.6.1.4.1.232.0.22005 cpqRackEnclosureTempFailed00
1.3.6.1.4.1.232.0.22006 cpqRackEnclosureTempDegraded00
1.3.6.1.4.1.232.0.22007 cpqRackEnclosureTempOk00
1.3.6.1.4.1.232.0.22009 cpqRackEnclosureFanDegraded00
1.3.6.1.4.1.232.0.22010 cpqRackEnclosureFanOk00
1.3.6.1.4.1.232.0.22011 cpqRackEnclosureFanRemoved00
1.3.6.1.4.1.232.0.22012 cpqRackEnclosureFanInserted00
1.3.6.1.4.1.232.0.22013 cpqRackPowerSupplyFailed00
1.3.6.1.4.1.232.0.22014 cpqRackPowerSupplyDegraded00
1.3.6.1.4.1.232.0.22015 cpqRackPowerSupplyOk00
1.3.6.1.4.1.232.0.22016 cpqRackPowerSupplyRemoved00
1.3.6.1.4.1.232.0.22017 cpqRackPowerSupplyInserted00
1.3.6.1.4.1.232.0.22018 cpqRackPowerSubsystemNotRedundant00
1.3.6.1.4.1.232.0.22019 cpqRackPowerSubsystemLineVoltageProblem00
1.3.6.1.4.1.232.0.22020 cpqRackPowerSubsystemOverloadCondition00
1.3.6.1.4.1.232.0.22021 cpqRackPowerShedAutoShutdown00
1.3.6.1.4.1.232.0.22022 cpqRackServerPowerOnFailedNotRedundant00
1.3.6.1.4.1.232.0.22023 cpqRackServerPowerOnFailedNotEnoughPower00
1.3.6.1.4.1.232.0.22024 cpqRackServerPowerOnFailedEnclosureNotFound00
1.3.6.1.4.1.232.0.22025 cpqRackServerPowerOnFailedPowerChassisNotFound00
1.3.6.1.4.1.232.0.22026 cpqRackServerPowerOnManualOverride00
1.3.6.1.4.1.232.0.22027 cpqRackFuseOpen00
1.3.6.1.4.1.232.0.22028 cpqRackServerBladeRemoved00
1.3.6.1.4.1.232.0.22029 cpqRackServerBladeInserted00