Reference record for OID 1.3.6.1.4.1.232.0.22022

Parent
1.3.6.1.4.1.232.0 (0)
Node code
22022
Node name
cpqRackServerPowerOnFailedNotRedundant
Numeric OID
1.3.6.1.4.1.232.0.22022
URN notation
urn:oid:1.3.6.1.4.1.232.0.22022
ASN.1 notation

{1 3 6 1 4 1 232 0 22022}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/22022
  • /ISO/Identified-Organization/6/1/4/1/232/0/22022
  • /ISO/3/6/1/4/1/232/0/22022
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • Additional combinations skipped.

Descriptions

cpqRackServerPowerOnFailedNotRedundant — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User Action: Check power connections or add power supplies.

Source records

cpqRackServerPowerOnFailedNotRedundant

Status in source: unspecified.

Names: cpqRackServerPowerOnFailedNotRedundant

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqRackServerPowerOnFailedNotRedundant",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqRackName",
    ",",
    "cpqRackUid",
    ",",
    "cpqRackServerBladeEnclosureName",
    ",",
    "cpqRackServerBladePosition",
    ",",
    "cpqRackServerBladeSparePartNumber",
    ",",
    "cpqRackCommonEnclosureSerialNum",
    ",",
    "cpqRackCommonEnclosureTrapSequenceNum",
    "}",
    "DESCRIPTION",
    "\"Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User Action: Check power connections or add power supplies.\"",
    "::=",
    "22022"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqRackName",
        "cpqRackUid",
        "cpqRackServerBladeEnclosureName",
        "cpqRackServerBladePosition",
        "cpqRackServerBladeSparePartNumber",
        "cpqRackCommonEnclosureSerialNum",
        "cpqRackCommonEnclosureTrapSequenceNum"
      ]
    ],
    [
      "DESCRIPTION",
      "Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User Action: Check power connections or add power supplies."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQRACK-MIB

    Published definition
    cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackServerBladeEnclosureName,
                         cpqRackServerBladePosition,
                         cpqRackServerBladeSparePartNumber,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "Server power on prevented to preserve redundancy.
    
                There is not enough power to power on the server blade and
                maintain redundancy for the other blades in the enclosure.
    
                User Action: Check power connections or add power supplies."
    
            --#TYPE "Server power on prevented to preserve redundancy (22022)"
            --#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
            --#ARGUMENTS {5, 4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
    
            ::= 22022
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK.MIB.txt
    Source location: CPQRACK-MIB::cpqRackServerPowerOnFailedNotRedundant.
    Source version and references

    Archived: 2026-10-19T00:22:08.787249+00:00.

  • Preserved circitor archive

    Module: CPQRACK-MIB

    Published definition
    cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackServerBladeEnclosureName,
                         cpqRackServerBladePosition,
                         cpqRackServerBladeSparePartNumber,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "Server power on prevented to preserve redundancy.
    
                There is not enough power to power on the server blade and
                maintain redundancy for the other blades in the enclosure.
    
                User Action: Check power connections or add power supplies."
    
            --#TYPE "Server power on prevented to preserve redundancy (22022)"
            --#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
            --#ARGUMENTS {5, 4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
    
            ::= 22022
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB.mib
    Source location: CPQRACK-MIB::cpqRackServerPowerOnFailedNotRedundant.
    Source version and references

    Archived: 2026-10-19T00:22:16.793075+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQRACK-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQRACK-MIB

    Published definition
    cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackServerBladeEnclosureName,
                         cpqRackServerBladePosition,
                         cpqRackServerBladeSparePartNumber,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "Server power on prevented to preserve redundancy.
    
                There is not enough power to power on the server blade and
                maintain redundancy for the other blades in the enclosure.
    
                User Action: Check power connections or add power supplies."
    
            --#TYPE "Server power on prevented to preserve redundancy (22022)"
            --#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
            --#ARGUMENTS {5, 4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY POWER
            --#ACTION "Check the power connections for problems, then add power supplies if necessary."
            
            ::= 22022
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoOsType', 'cpqHoVersion'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB

    Related source files and packages:


    Source location: CPQRACK-MIB::cpqRackServerPowerOnFailedNotRedundant.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.143420+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQRACK-MIB

    Published definition
    cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackServerBladeEnclosureName,
                         cpqRackServerBladePosition,
                         cpqRackServerBladeSparePartNumber,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "Server power on prevented to preserve redundancy.
    
                There is not enough power to power on the server blade and
                maintain redundancy for the other blades in the enclosure.
    
                User Action: Check power connections or add power supplies."
    
            --#TYPE "Server power on prevented to preserve redundancy (22022)"
            --#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
            --#ARGUMENTS {5, 4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY POWER
            --#ACTION "Check the power connections for problems, then add power supplies if necessary."
            
            ::= 22022
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoOsType', 'cpqHoVersion'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB

    Related source files and packages:


    Source location: CPQRACK-MIB::cpqRackServerPowerOnFailedNotRedundant.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.206277+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.13603620 sCellEventTrap-0e-2400
1.3.6.1.4.1.232.0.13603621 sCellEventTrap-0e-2500
1.3.6.1.4.1.232.0.13603622 sCellEventTrap-0e-2600
1.3.6.1.4.1.232.0.13603623 sCellEventTrap-0e-2700
1.3.6.1.4.1.232.0.13603624 sCellEventTrap-0e-2800
1.3.6.1.4.1.232.0.13603625 sCellEventTrap-0e-2900
1.3.6.1.4.1.232.0.13603626 sCellEventTrap-0e-2a00
1.3.6.1.4.1.232.0.13603627 sCellEventTrap-0e-2b00
1.3.6.1.4.1.232.0.13603628 sCellEventTrap-0e-2c00
1.3.6.1.4.1.232.0.13603629 sCellEventTrap-0e-2d00
1.3.6.1.4.1.232.0.13603630 sCellEventTrap-0e-2e00
1.3.6.1.4.1.232.0.13603631 sCellEventTrap-0e-2f00
1.3.6.1.4.1.232.0.13603636 sCellEventTrap-0e-3400
1.3.6.1.4.1.232.0.13603637 sCellEventTrap-0e-3500
1.3.6.1.4.1.232.0.13603638 sCellEventTrap-0e-3600
1.3.6.1.4.1.232.0.13603639 sCellEventTrap-0e-3700
1.3.6.1.4.1.232.0.13603640 sCellEventTrap-0e-3800
1.3.6.1.4.1.232.0.13603641 sCellEventTrap-0e-3900
1.3.6.1.4.1.232.0.13603642 sCellEventTrap-0e-3a00
1.3.6.1.4.1.232.0.13603643 sCellEventTrap-0e-3b00
1.3.6.1.4.1.232.0.13603644 sCellEventTrap-0e-3c00
1.3.6.1.4.1.232.0.13603645 sCellEventTrap-0e-3d00
1.3.6.1.4.1.232.0.13603646 sCellEventTrap-0e-3e00
1.3.6.1.4.1.232.0.13603647 sCellEventTrap-0e-3f00
1.3.6.1.4.1.232.0.13603648 sCellEventTrap-0e-4000
1.3.6.1.4.1.232.0.13603649 sCellEventTrap-0e-4100
1.3.6.1.4.1.232.0.13603650 sCellEventTrap-0e-4200
1.3.6.1.4.1.232.0.13603651 sCellEventTrap-0e-4300
1.3.6.1.4.1.232.0.13603652 sCellEventTrap-0e-4400
1.3.6.1.4.1.232.0.13603653 sCellEventTrap-0e-4500
1.3.6.1.4.1.232.0.13603654 sCellEventTrap-0e-4600
1.3.6.1.4.1.232.0.13603655 sCellEventTrap-0e-4700
1.3.6.1.4.1.232.0.13603656 sCellEventTrap-0e-4800
1.3.6.1.4.1.232.0.13603657 sCellEventTrap-0e-4900
1.3.6.1.4.1.232.0.13603658 sCellEventTrap-0e-4a00
1.3.6.1.4.1.232.0.13603659 sCellEventTrap-0e-4b00
1.3.6.1.4.1.232.0.13603660 sCellEventTrap-0e-4c00
1.3.6.1.4.1.232.0.13603661 sCellEventTrap-0e-4d00
1.3.6.1.4.1.232.0.13603662 sCellEventTrap-0e-4e00
1.3.6.1.4.1.232.0.13603663 sCellEventTrap-0e-4f00
1.3.6.1.4.1.232.0.13603664 sCellEventTrap-0e-5000
1.3.6.1.4.1.232.0.13603665 sCellEventTrap-0e-5100
1.3.6.1.4.1.232.0.13603666 sCellEventTrap-0e-5200
1.3.6.1.4.1.232.0.13603667 sCellEventTrap-0e-5300
1.3.6.1.4.1.232.0.13603668 sCellEventTrap-0e-5400
1.3.6.1.4.1.232.0.13603669 sCellEventTrap-0e-5500
1.3.6.1.4.1.232.0.13603670 sCellEventTrap-0e-5600
1.3.6.1.4.1.232.0.13603671 sCellEventTrap-0e-5700
1.3.6.1.4.1.232.0.13603712 sCellEventTrap-0e-8000
1.3.6.1.4.1.232.0.13603713 sCellEventTrap-0e-8100