Reference record for OID 1.3.6.1.4.1.232.0.22037

Parent
1.3.6.1.4.1.232.0 (0)
Node code
22037
Node name
cpqRackEnclosureManagerDegraded
Numeric OID
1.3.6.1.4.1.232.0.22037
URN notation
urn:oid:1.3.6.1.4.1.232.0.22037
ASN.1 notation

{1 3 6 1 4 1 232 0 22037}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/22037
  • /ISO/Identified-Organization/6/1/4/1/232/0/22037
  • /ISO/3/6/1/4/1/232/0/22037
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqRackEnclosureManagerDegraded
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqRackEnclosureManagerDegraded
  • Additional combinations skipped.

Descriptions

cpqRackEnclosureManagerDegraded — Circitor, MIBdepot

The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either an Onboard Administrator has failed but the other Onboard Administrator is still operating, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, replace the Onboard Administrator as soon as possible. For all others please refer to product documenation for possible corrective actions

cpqRackEnclosureManagerDegraded — HPE networking MIB copies (LibreNMS/Observium Community)

The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed, their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG. For all the others please refer to product documentation for possible corrective actions

Source records

cpqRackEnclosureManagerDegraded

Status in source: unspecified.

Names: cpqRackEnclosureManagerDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqRackEnclosureManagerDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqRackName",
    ",",
    "cpqRackUid",
    ",",
    "cpqRackCommonEnclosureName",
    ",",
    "cpqRackCommonEnclosureSerialNum",
    ",",
    "cpqRackCommonEnclosureManagerLocation",
    ",",
    "cpqRackCommonEnclosureManagerSparePartNumber",
    ",",
    "cpqRackCommonEnclosureManagerSerialNum",
    ",",
    "cpqRackCommonEnclosureTrapSequenceNum",
    "}",
    "DESCRIPTION",
    "\"The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either an Onboard Administrator has failed but the other Onboard Administrator is still operating, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, replace the Onboard Administrator as soon as possible. For all others please refer to product documenation for possible corrective actions\"",
    "::=",
    "22037"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqRackName",
        "cpqRackUid",
        "cpqRackCommonEnclosureName",
        "cpqRackCommonEnclosureSerialNum",
        "cpqRackCommonEnclosureManagerLocation",
        "cpqRackCommonEnclosureManagerSparePartNumber",
        "cpqRackCommonEnclosureManagerSerialNum",
        "cpqRackCommonEnclosureTrapSequenceNum"
      ]
    ],
    [
      "DESCRIPTION",
      "The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either an Onboard Administrator has failed but the other Onboard Administrator is still operating, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, replace the Onboard Administrator as soon as possible. For all others please refer to product documenation for possible corrective actions"
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureManagerDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureManagerLocation,
                         cpqRackCommonEnclosureManagerSparePartNumber,
                         cpqRackCommonEnclosureManagerSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The Onboard Administrator or other management processor status has been set to degraded.
    
                This trap signifies that either an Onboard Administrator has failed but
                the other Onboard Administrator is still operating, or one or more management processors is in
                a non-optimal operating state.
    
                User Action: For C-Class enclosures, replace the Onboard Administrator as soon as possible.
                For all others please refer to product documenation for possible corrective actions"
    
            --#TYPE "Enclosure manager degraded (22037)"
            --#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
            --#ARGUMENTS {4, 2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
            ::= 22037
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK.MIB.txt
    Source location: CPQRACK-MIB::cpqRackEnclosureManagerDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.787249+00:00.

  • Preserved circitor archive

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureManagerDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureManagerLocation,
                         cpqRackCommonEnclosureManagerSparePartNumber,
                         cpqRackCommonEnclosureManagerSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The Onboard Administrator or other management processor status has been set to degraded.
    
                This trap signifies that either an Onboard Administrator has failed but
                the other Onboard Administrator is still operating, or one or more management processors is in 
                a non-optimal operating state.
    
                User Action: For C-Class enclosures, replace the Onboard Administrator as soon as possible.
                For all others please refer to product documenation for possible corrective actions"
    
            --#TYPE "Enclosure manager degraded (22037)"
            --#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
            --#ARGUMENTS {4, 2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
            ::= 22037
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB.mib
    Source location: CPQRACK-MIB::cpqRackEnclosureManagerDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:16.793075+00:00.

cpqRackEnclosureManagerDegraded

Status in source: unspecified.

Names: cpqRackEnclosureManagerDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqRackEnclosureManagerDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqRackName",
    ",",
    "cpqRackUid",
    ",",
    "cpqRackCommonEnclosureName",
    ",",
    "cpqRackCommonEnclosureSerialNum",
    ",",
    "cpqRackCommonEnclosureManagerLocation",
    ",",
    "cpqRackCommonEnclosureManagerSparePartNumber",
    ",",
    "cpqRackCommonEnclosureManagerSerialNum",
    ",",
    "cpqRackCommonEnclosureTrapSequenceNum",
    "}",
    "DESCRIPTION",
    "\"The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed, their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG. For all the others please refer to product documentation for possible corrective actions\"",
    "::=",
    "22037"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqRackName",
        "cpqRackUid",
        "cpqRackCommonEnclosureName",
        "cpqRackCommonEnclosureSerialNum",
        "cpqRackCommonEnclosureManagerLocation",
        "cpqRackCommonEnclosureManagerSparePartNumber",
        "cpqRackCommonEnclosureManagerSerialNum",
        "cpqRackCommonEnclosureTrapSequenceNum"
      ]
    ],
    [
      "DESCRIPTION",
      "The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed, their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG. For all the others please refer to product documentation for possible corrective actions"
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQRACK-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureManagerDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureManagerLocation,
                         cpqRackCommonEnclosureManagerSparePartNumber,
                         cpqRackCommonEnclosureManagerSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The Onboard Administrator or other management processor status has been set to degraded.
    
                This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed,
                their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state.
    
                User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG.
                For all the others please refer to product documentation for possible corrective actions"
    
            --#TYPE "Enclosure manager degraded (22037)"
            --#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
            --#ARGUMENTS {4, 2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY OA
            --#ACTION "The following conditions can result in a degraded Onboard Administrator (OA): 1) one OA failed but the second OA is still operating, 2) one or more OAs is in a non-optimal operating state, 3) a firmware revision mismatch occurred between the primary and secondary OAs, or 4) OA RTC battery is low.  To determine what caused the issue, see the OA and check the logs for more  information.    If a firmware mismatch occurred, use the OA UI or CLI (UPDATE IMAGE SYNC command) to resynchronize the firmware on the OAs.   If OA RTC battery  is found to be low, replace battery."
    
            
            ::= 22037
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoOsType', 'cpqHoVersion'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB

    Related source files and packages:


    Source location: CPQRACK-MIB::cpqRackEnclosureManagerDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.143420+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureManagerDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureManagerLocation,
                         cpqRackCommonEnclosureManagerSparePartNumber,
                         cpqRackCommonEnclosureManagerSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The Onboard Administrator or other management processor status has been set to degraded.
    
                This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed,
                their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state.
    
                User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG.
                For all the others please refer to product documentation for possible corrective actions"
    
            --#TYPE "Enclosure manager degraded (22037)"
            --#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
            --#ARGUMENTS {4, 2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY OA
            --#ACTION "The following conditions can result in a degraded Onboard Administrator (OA): 1) one OA failed but the second OA is still operating, 2) one or more OAs is in a non-optimal operating state, 3) a firmware revision mismatch occurred between the primary and secondary OAs, or 4) OA RTC battery is low.  To determine what caused the issue, see the OA and check the logs for more  information.    If a firmware mismatch occurred, use the OA UI or CLI (UPDATE IMAGE SYNC command) to resynchronize the firmware on the OAs.   If OA RTC battery  is found to be low, replace battery."
    
            
            ::= 22037
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoOsType', 'cpqHoVersion'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB

    Related source files and packages:


    Source location: CPQRACK-MIB::cpqRackEnclosureManagerDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.206277+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.13603714 sCellEventTrap-0e-8200
1.3.6.1.4.1.232.0.13603715 sCellEventTrap-0e-8300
1.3.6.1.4.1.232.0.13603716 sCellEventTrap-0e-8400
1.3.6.1.4.1.232.0.13603717 sCellEventTrap-0e-8500
1.3.6.1.4.1.232.0.13603718 sCellEventTrap-0e-8600
1.3.6.1.4.1.232.0.13603719 sCellEventTrap-0e-8700
1.3.6.1.4.1.232.0.13603720 sCellEventTrap-0e-8800
1.3.6.1.4.1.232.0.13603721 sCellEventTrap-0e-8900
1.3.6.1.4.1.232.0.13603722 sCellEventTrap-0e-8a00
1.3.6.1.4.1.232.0.13603723 sCellEventTrap-0e-8b00
1.3.6.1.4.1.232.0.13603724 sCellEventTrap-0e-8c00
1.3.6.1.4.1.232.0.13603725 sCellEventTrap-0e-8d00
1.3.6.1.4.1.232.0.13603726 sCellEventTrap-0e-8e00
1.3.6.1.4.1.232.0.13603727 sCellEventTrap-0e-8f00
1.3.6.1.4.1.232.0.13603728 sCellEventTrap-0e-9000
1.3.6.1.4.1.232.0.13603729 sCellEventTrap-0e-9100
1.3.6.1.4.1.232.0.13603730 sCellEventTrap-0e-9200
1.3.6.1.4.1.232.0.13603731 sCellEventTrap-0e-9300
1.3.6.1.4.1.232.0.13603732 sCellEventTrap-0e-9400
1.3.6.1.4.1.232.0.13603733 sCellEventTrap-0e-9500
1.3.6.1.4.1.232.0.13603734 sCellEventTrap-0e-9600
1.3.6.1.4.1.232.0.13603735 sCellEventTrap-0e-9700
1.3.6.1.4.1.232.0.13603736 sCellEventTrap-0e-9800
1.3.6.1.4.1.232.0.13603737 sCellEventTrap-0e-9900
1.3.6.1.4.1.232.0.13603738 sCellEventTrap-0e-9a00
1.3.6.1.4.1.232.0.13603739 sCellEventTrap-0e-9b00
1.3.6.1.4.1.232.0.13603740 sCellEventTrap-0e-9c00
1.3.6.1.4.1.232.0.13603741 sCellEventTrap-0e-9d00
1.3.6.1.4.1.232.0.13603742 sCellEventTrap-0e-9e00
1.3.6.1.4.1.232.0.13603743 sCellEventTrap-0e-9f00
1.3.6.1.4.1.232.0.13603744 sCellEventTrap-0e-a000
1.3.6.1.4.1.232.0.13603745 sCellEventTrap-0e-a100
1.3.6.1.4.1.232.0.13603746 sCellEventTrap-0e-a200
1.3.6.1.4.1.232.0.13603747 sCellEventTrap-0e-a300
1.3.6.1.4.1.232.0.13603748 sCellEventTrap-0e-a400
1.3.6.1.4.1.232.0.13603749 sCellEventTrap-0e-a500
1.3.6.1.4.1.232.0.13603750 sCellEventTrap-0e-a600
1.3.6.1.4.1.232.0.13603751 sCellEventTrap-0e-a700
1.3.6.1.4.1.232.0.13603752 sCellEventTrap-0e-a800
1.3.6.1.4.1.232.0.13603753 sCellEventTrap-0e-a900
1.3.6.1.4.1.232.0.13603754 sCellEventTrap-0e-aa00
1.3.6.1.4.1.232.0.13603840 sCellEventTrap-0f-0000
1.3.6.1.4.1.232.0.13603841 sCellEventTrap-0f-0100
1.3.6.1.4.1.232.0.13603842 sCellEventTrap-0f-0200
1.3.6.1.4.1.232.0.13603843 sCellEventTrap-0f-0300
1.3.6.1.4.1.232.0.13603844 sCellEventTrap-0f-0400
1.3.6.1.4.1.232.0.13603845 sCellEventTrap-0f-0500
1.3.6.1.4.1.232.0.13603846 sCellEventTrap-0f-0600
1.3.6.1.4.1.232.0.13603847 sCellEventTrap-0f-0700
1.3.6.1.4.1.232.0.13603848 sCellEventTrap-0f-0800