Reference record for OID 1.3.6.1.4.1.232.0.22037

Parent
1.3.6.1.4.1.232.0 (0)
Node code
22037
Node name
cpqRackEnclosureManagerDegraded
Numeric OID
1.3.6.1.4.1.232.0.22037
URN notation
urn:oid:1.3.6.1.4.1.232.0.22037
ASN.1 notation

{1 3 6 1 4 1 232 0 22037}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqRackEnclosureManagerDegraded(22037)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/22037
  • /ISO/Identified-Organization/6/1/4/1/232/0/22037
  • /ISO/3/6/1/4/1/232/0/22037
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqRackEnclosureManagerDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqRackEnclosureManagerDegraded
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqRackEnclosureManagerDegraded
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqRackEnclosureManagerDegraded
  • Additional combinations skipped.

Descriptions

cpqRackEnclosureManagerDegraded — Circitor, MIBdepot

The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either an Onboard Administrator has failed but the other Onboard Administrator is still operating, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, replace the Onboard Administrator as soon as possible. For all others please refer to product documenation for possible corrective actions

cpqRackEnclosureManagerDegraded — HPE networking MIB copies (LibreNMS/Observium Community)

The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed, their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG. For all the others please refer to product documentation for possible corrective actions

Source records

cpqRackEnclosureManagerDegraded

Status in source: unspecified.

Names: cpqRackEnclosureManagerDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqRackEnclosureManagerDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqRackName",
    ",",
    "cpqRackUid",
    ",",
    "cpqRackCommonEnclosureName",
    ",",
    "cpqRackCommonEnclosureSerialNum",
    ",",
    "cpqRackCommonEnclosureManagerLocation",
    ",",
    "cpqRackCommonEnclosureManagerSparePartNumber",
    ",",
    "cpqRackCommonEnclosureManagerSerialNum",
    ",",
    "cpqRackCommonEnclosureTrapSequenceNum",
    "}",
    "DESCRIPTION",
    "\"The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either an Onboard Administrator has failed but the other Onboard Administrator is still operating, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, replace the Onboard Administrator as soon as possible. For all others please refer to product documenation for possible corrective actions\"",
    "::=",
    "22037"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqRackName",
        "cpqRackUid",
        "cpqRackCommonEnclosureName",
        "cpqRackCommonEnclosureSerialNum",
        "cpqRackCommonEnclosureManagerLocation",
        "cpqRackCommonEnclosureManagerSparePartNumber",
        "cpqRackCommonEnclosureManagerSerialNum",
        "cpqRackCommonEnclosureTrapSequenceNum"
      ]
    ],
    [
      "DESCRIPTION",
      "The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either an Onboard Administrator has failed but the other Onboard Administrator is still operating, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, replace the Onboard Administrator as soon as possible. For all others please refer to product documenation for possible corrective actions"
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureManagerDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureManagerLocation,
                         cpqRackCommonEnclosureManagerSparePartNumber,
                         cpqRackCommonEnclosureManagerSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The Onboard Administrator or other management processor status has been set to degraded.
    
                This trap signifies that either an Onboard Administrator has failed but
                the other Onboard Administrator is still operating, or one or more management processors is in
                a non-optimal operating state.
    
                User Action: For C-Class enclosures, replace the Onboard Administrator as soon as possible.
                For all others please refer to product documenation for possible corrective actions"
    
            --#TYPE "Enclosure manager degraded (22037)"
            --#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
            --#ARGUMENTS {4, 2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
            ::= 22037
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK.MIB.txt
    Source location: CPQRACK-MIB::cpqRackEnclosureManagerDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.787249+00:00.

  • Preserved circitor archive

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureManagerDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureManagerLocation,
                         cpqRackCommonEnclosureManagerSparePartNumber,
                         cpqRackCommonEnclosureManagerSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The Onboard Administrator or other management processor status has been set to degraded.
    
                This trap signifies that either an Onboard Administrator has failed but
                the other Onboard Administrator is still operating, or one or more management processors is in 
                a non-optimal operating state.
    
                User Action: For C-Class enclosures, replace the Onboard Administrator as soon as possible.
                For all others please refer to product documenation for possible corrective actions"
    
            --#TYPE "Enclosure manager degraded (22037)"
            --#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
            --#ARGUMENTS {4, 2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
    
            ::= 22037
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB.mib
    Source location: CPQRACK-MIB::cpqRackEnclosureManagerDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:16.793075+00:00.

cpqRackEnclosureManagerDegraded

Status in source: unspecified.

Names: cpqRackEnclosureManagerDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqRackEnclosureManagerDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqRackName",
    ",",
    "cpqRackUid",
    ",",
    "cpqRackCommonEnclosureName",
    ",",
    "cpqRackCommonEnclosureSerialNum",
    ",",
    "cpqRackCommonEnclosureManagerLocation",
    ",",
    "cpqRackCommonEnclosureManagerSparePartNumber",
    ",",
    "cpqRackCommonEnclosureManagerSerialNum",
    ",",
    "cpqRackCommonEnclosureTrapSequenceNum",
    "}",
    "DESCRIPTION",
    "\"The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed, their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG. For all the others please refer to product documentation for possible corrective actions\"",
    "::=",
    "22037"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqRackName",
        "cpqRackUid",
        "cpqRackCommonEnclosureName",
        "cpqRackCommonEnclosureSerialNum",
        "cpqRackCommonEnclosureManagerLocation",
        "cpqRackCommonEnclosureManagerSparePartNumber",
        "cpqRackCommonEnclosureManagerSerialNum",
        "cpqRackCommonEnclosureTrapSequenceNum"
      ]
    ],
    [
      "DESCRIPTION",
      "The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed, their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG. For all the others please refer to product documentation for possible corrective actions"
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQRACK-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureManagerDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureManagerLocation,
                         cpqRackCommonEnclosureManagerSparePartNumber,
                         cpqRackCommonEnclosureManagerSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The Onboard Administrator or other management processor status has been set to degraded.
    
                This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed,
                their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state.
    
                User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG.
                For all the others please refer to product documentation for possible corrective actions"
    
            --#TYPE "Enclosure manager degraded (22037)"
            --#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
            --#ARGUMENTS {4, 2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY OA
            --#ACTION "The following conditions can result in a degraded Onboard Administrator (OA): 1) one OA failed but the second OA is still operating, 2) one or more OAs is in a non-optimal operating state, 3) a firmware revision mismatch occurred between the primary and secondary OAs, or 4) OA RTC battery is low.  To determine what caused the issue, see the OA and check the logs for more  information.    If a firmware mismatch occurred, use the OA UI or CLI (UPDATE IMAGE SYNC command) to resynchronize the firmware on the OAs.   If OA RTC battery  is found to be low, replace battery."
    
            
            ::= 22037
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoOsType', 'cpqHoVersion'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB

    Related source files and packages:


    Source location: CPQRACK-MIB::cpqRackEnclosureManagerDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.143420+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQRACK-MIB

    Published definition
    cpqRackEnclosureManagerDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackCommonEnclosureName,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureManagerLocation,
                         cpqRackCommonEnclosureManagerSparePartNumber,
                         cpqRackCommonEnclosureManagerSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "The Onboard Administrator or other management processor status has been set to degraded.
    
                This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed,
                their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state.
    
                User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG.
                For all the others please refer to product documentation for possible corrective actions"
    
            --#TYPE "Enclosure manager degraded (22037)"
            --#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
            --#ARGUMENTS {4, 2}
            --#SEVERITY MAJOR
            --#TIMEINDEX 99
            --#STATE DEGRADED
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY OA
            --#ACTION "The following conditions can result in a degraded Onboard Administrator (OA): 1) one OA failed but the second OA is still operating, 2) one or more OAs is in a non-optimal operating state, 3) a firmware revision mismatch occurred between the primary and secondary OAs, or 4) OA RTC battery is low.  To determine what caused the issue, see the OA and check the logs for more  information.    If a firmware mismatch occurred, use the OA UI or CLI (UPDATE IMAGE SYNC command) to resynchronize the firmware on the OAs.   If OA RTC battery  is found to be low, replace battery."
    
            
            ::= 22037
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoOsType', 'cpqHoVersion'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB

    Related source files and packages:


    Source location: CPQRACK-MIB::cpqRackEnclosureManagerDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.206277+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.18004 cpqNicRedundancyReduced00
1.3.6.1.4.1.232.0.18005 cpqNic2ConnectivityRestored00
1.3.6.1.4.1.232.0.18006 cpqNic2ConnectivityLost00
1.3.6.1.4.1.232.0.18007 cpqNic2RedundancyIncreased00
1.3.6.1.4.1.232.0.18008 cpqNic2RedundancyReduced00
1.3.6.1.4.1.232.0.18009 cpqNicVirusLikeActivityDetected00
1.3.6.1.4.1.232.0.18010 cpqNicVirusLikeActivityStopped00
1.3.6.1.4.1.232.0.18011 cpqNic3ConnectivityRestored00
1.3.6.1.4.1.232.0.18012 cpqNic3ConnectivityLost00
1.3.6.1.4.1.232.0.18013 cpqNic3RedundancyIncreased00
1.3.6.1.4.1.232.0.18014 cpqNic3RedundancyReduced00
1.3.6.1.4.1.232.0.18015 cpqNicAllLinksDown00
1.3.6.1.4.1.232.0.18016 cpqNicAllLinksDownRepaired00
1.3.6.1.4.1.232.0.18017 cpqNicFlexLomTrainingFailed00
1.3.6.1.4.1.232.0.19001 cpqOsCpuTimeDegraded00
1.3.6.1.4.1.232.0.19002 cpqOsCpuTimeFailed00
1.3.6.1.4.1.232.0.19003 cpqOsCacheCopyReadHitsDegraded00
1.3.6.1.4.1.232.0.19004 cpqOsCacheCopyReadHitsFailed00
1.3.6.1.4.1.232.0.19005 cpqOsPageFileUsageDegraded00
1.3.6.1.4.1.232.0.19006 cpqOsPageFileUsageFailed00
1.3.6.1.4.1.232.0.19007 cpqOsLogicalDiskBusyTimeDegraded00
1.3.6.1.4.1.232.0.19008 cpqOsLogicalDiskBusyTimeFailed00
1.3.6.1.4.1.232.0.22001 cpqRackNameChanged00
1.3.6.1.4.1.232.0.22002 cpqRackEnclosureNameChanged00
1.3.6.1.4.1.232.0.22003 cpqRackEnclosureRemoved00
1.3.6.1.4.1.232.0.22004 cpqRackEnclosureInserted00
1.3.6.1.4.1.232.0.22005 cpqRackEnclosureTempFailed00
1.3.6.1.4.1.232.0.22006 cpqRackEnclosureTempDegraded00
1.3.6.1.4.1.232.0.22007 cpqRackEnclosureTempOk00
1.3.6.1.4.1.232.0.22008 cpqRackEnclosureFanFailed00
1.3.6.1.4.1.232.0.22009 cpqRackEnclosureFanDegraded00
1.3.6.1.4.1.232.0.22010 cpqRackEnclosureFanOk00
1.3.6.1.4.1.232.0.22011 cpqRackEnclosureFanRemoved00
1.3.6.1.4.1.232.0.22012 cpqRackEnclosureFanInserted00
1.3.6.1.4.1.232.0.22013 cpqRackPowerSupplyFailed00
1.3.6.1.4.1.232.0.22014 cpqRackPowerSupplyDegraded00
1.3.6.1.4.1.232.0.22015 cpqRackPowerSupplyOk00
1.3.6.1.4.1.232.0.22016 cpqRackPowerSupplyRemoved00
1.3.6.1.4.1.232.0.22017 cpqRackPowerSupplyInserted00
1.3.6.1.4.1.232.0.22018 cpqRackPowerSubsystemNotRedundant00
1.3.6.1.4.1.232.0.22019 cpqRackPowerSubsystemLineVoltageProblem00
1.3.6.1.4.1.232.0.22020 cpqRackPowerSubsystemOverloadCondition00
1.3.6.1.4.1.232.0.22021 cpqRackPowerShedAutoShutdown00
1.3.6.1.4.1.232.0.22022 cpqRackServerPowerOnFailedNotRedundant00
1.3.6.1.4.1.232.0.22023 cpqRackServerPowerOnFailedNotEnoughPower00
1.3.6.1.4.1.232.0.22024 cpqRackServerPowerOnFailedEnclosureNotFound00
1.3.6.1.4.1.232.0.22025 cpqRackServerPowerOnFailedPowerChassisNotFound00
1.3.6.1.4.1.232.0.22026 cpqRackServerPowerOnManualOverride00
1.3.6.1.4.1.232.0.22027 cpqRackFuseOpen00
1.3.6.1.4.1.232.0.22028 cpqRackServerBladeRemoved00