Reference record for OID 1.3.6.1.4.1.232.0.3046

Parent
1.3.6.1.4.1.232.0 (0)
Node code
3046
Node name
cpqDa7PhyDrvStatusChange
Numeric OID
1.3.6.1.4.1.232.0.3046
URN notation
urn:oid:1.3.6.1.4.1.232.0.3046
ASN.1 notation

{1 3 6 1 4 1 232 0 3046}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/3046
  • /ISO/Identified-Organization/6/1/4/1/232/0/3046
  • /ISO/3/6/1/4/1/232/0/3046
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqDa7PhyDrvStatusChange
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqDa7PhyDrvStatusChange
  • Additional combinations skipped.

Descriptions

cpqDa7PhyDrvStatusChange — Circitor, MIBdepot

Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive.

cpqDa7PhyDrvStatusChange — HPE networking MIB copies (LibreNMS/Observium Community)

Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)', replace the drive.

cpqDa7PhyDrvStatusChange — HPE networking MIB copies (LibreNMS/Observium Community)

Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is `failed(3)`, `predictiveFailure(4)`, `ssdWearOut(8)`, or `notAuthenticated(9)`, replace the drive.

Source records

cpqDa7PhyDrvStatusChange

Status in source: unspecified.

Names: cpqDa7PhyDrvStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqDa7PhyDrvStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqDaCntlrHwLocation",
    ",",
    "cpqDaPhyDrvCntlrIndex",
    ",",
    "cpqDaPhyDrvIndex",
    ",",
    "cpqDaPhyDrvLocationString",
    ",",
    "cpqDaPhyDrvType",
    ",",
    "cpqDaPhyDrvModel",
    ",",
    "cpqDaPhyDrvFWRev",
    ",",
    "cpqDaPhyDrvSerialNum",
    ",",
    "cpqDaPhyDrvFailureCode",
    ",",
    "cpqDaPhyDrvStatus",
    ",",
    "cpqDaPhyDrvBusNumber",
    "}",
    "DESCRIPTION",
    "\"Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive.\"",
    "::=",
    "3046"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqDaCntlrHwLocation",
        "cpqDaPhyDrvCntlrIndex",
        "cpqDaPhyDrvIndex",
        "cpqDaPhyDrvLocationString",
        "cpqDaPhyDrvType",
        "cpqDaPhyDrvModel",
        "cpqDaPhyDrvFWRev",
        "cpqDaPhyDrvSerialNum",
        "cpqDaPhyDrvFailureCode",
        "cpqDaPhyDrvStatus",
        "cpqDaPhyDrvBusNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQIDA-MIB

    Published definition
    cpqDa7PhyDrvStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
                         cpqDaPhyDrvCntlrIndex, cpqDaPhyDrvIndex,
                         cpqDaPhyDrvLocationString, cpqDaPhyDrvType,
                         cpqDaPhyDrvModel, cpqDaPhyDrvFWRev, cpqDaPhyDrvSerialNum,
                         cpqDaPhyDrvFailureCode, cpqDaPhyDrvStatus,
                         cpqDaPhyDrvBusNumber }
            DESCRIPTION
                "Physical Drive Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of a drive array physical drive.  The variable
                 cpaDaPhyDrvStatus indicates the current physical drive status.
    
                 User Action: If the physical drive status is failed(3) or
                 predictiveFailure(4), replace the drive."
    
            --#TYPE "Physical Drive Status Change (3046)"
            --#SUMMARY "Physical Drive Status is now %d."
            --#ARGUMENTS {11}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
    
            ::= 3046
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA.MIB.txt
    Source location: CPQIDA-MIB::cpqDa7PhyDrvStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.781630+00:00.

  • Preserved circitor archive

    Module: CPQIDA-MIB

    Published definition
    cpqDa7PhyDrvStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
                         cpqDaPhyDrvCntlrIndex, cpqDaPhyDrvIndex,
                         cpqDaPhyDrvLocationString, cpqDaPhyDrvType,
                         cpqDaPhyDrvModel, cpqDaPhyDrvFWRev, cpqDaPhyDrvSerialNum,
                         cpqDaPhyDrvFailureCode, cpqDaPhyDrvStatus,
                         cpqDaPhyDrvBusNumber }
            DESCRIPTION
                "Physical Drive Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of a drive array physical drive.  The variable
                 cpaDaPhyDrvStatus indicates the current physical drive status.
    
                 User Action: If the physical drive status is failed(3) or
                 predictiveFailure(4), replace the drive."
    
            --#TYPE "Physical Drive Status Change (3046)"
            --#SUMMARY "Physical Drive Status is now %d."
            --#ARGUMENTS {11}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
    
            ::= 3046
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA-MIB.mib
    Source location: CPQIDA-MIB::cpqDa7PhyDrvStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:16.779739+00:00.

cpqDa7PhyDrvStatusChange

Status in source: unspecified.

Names: cpqDa7PhyDrvStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqDa7PhyDrvStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqDaCntlrHwLocation",
    ",",
    "cpqDaPhyDrvCntlrIndex",
    ",",
    "cpqDaPhyDrvIndex",
    ",",
    "cpqDaPhyDrvLocationString",
    ",",
    "cpqDaPhyDrvType",
    ",",
    "cpqDaPhyDrvModel",
    ",",
    "cpqDaPhyDrvFWRev",
    ",",
    "cpqDaPhyDrvSerialNum",
    ",",
    "cpqDaPhyDrvFailureCode",
    ",",
    "cpqDaPhyDrvStatus",
    ",",
    "cpqDaPhyDrvBusNumber",
    "}",
    "DESCRIPTION",
    "\"Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)', replace the drive.\"",
    "::=",
    "3046"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqDaCntlrHwLocation",
        "cpqDaPhyDrvCntlrIndex",
        "cpqDaPhyDrvIndex",
        "cpqDaPhyDrvLocationString",
        "cpqDaPhyDrvType",
        "cpqDaPhyDrvModel",
        "cpqDaPhyDrvFWRev",
        "cpqDaPhyDrvSerialNum",
        "cpqDaPhyDrvFailureCode",
        "cpqDaPhyDrvStatus",
        "cpqDaPhyDrvBusNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)', replace the drive."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQIDA-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQIDA-MIB

    Published definition
    cpqDa7PhyDrvStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
                         cpqDaPhyDrvCntlrIndex, cpqDaPhyDrvIndex,
                         cpqDaPhyDrvLocationString, cpqDaPhyDrvType,
                         cpqDaPhyDrvModel, cpqDaPhyDrvFWRev, cpqDaPhyDrvSerialNum,
                         cpqDaPhyDrvFailureCode, cpqDaPhyDrvStatus,
                         cpqDaPhyDrvBusNumber }
            DESCRIPTION
                "Physical Drive Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of a drive array physical drive.  The variable
                 cpaDaPhyDrvStatus indicates the current physical drive status.
    
                 User Action: If cpaDaPhyDrvStatus is 'failed(3)',
                 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)',
                 replace the drive."
    
            --#TYPE "Physical Drive Status Change (3046)"
            --#SUMMARY "Physical drive status is now %d for drive at location %s connected to controller in %s."
            --#ARGUMENTS {11, 5, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY STORAGE
            --#ACTION "If the physical drive status is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)', replace the drive."
            
            ::= 3046
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA-MIB

    Related source files and packages:


    Source location: CPQIDA-MIB::cpqDa7PhyDrvStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.136420+00:00.

cpqDa7PhyDrvStatusChange

Status in source: unspecified.

Names: cpqDa7PhyDrvStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqDa7PhyDrvStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqDaCntlrHwLocation",
    ",",
    "cpqDaPhyDrvCntlrIndex",
    ",",
    "cpqDaPhyDrvIndex",
    ",",
    "cpqDaPhyDrvLocationString",
    ",",
    "cpqDaPhyDrvType",
    ",",
    "cpqDaPhyDrvModel",
    ",",
    "cpqDaPhyDrvFWRev",
    ",",
    "cpqDaPhyDrvSerialNum",
    ",",
    "cpqDaPhyDrvFailureCode",
    ",",
    "cpqDaPhyDrvStatus",
    ",",
    "cpqDaPhyDrvBusNumber",
    "}",
    "DESCRIPTION",
    "\"Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is `failed(3)`, `predictiveFailure(4)`, `ssdWearOut(8)`, or `notAuthenticated(9)`, replace the drive.\"",
    "::=",
    "3046"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqDaCntlrHwLocation",
        "cpqDaPhyDrvCntlrIndex",
        "cpqDaPhyDrvIndex",
        "cpqDaPhyDrvLocationString",
        "cpqDaPhyDrvType",
        "cpqDaPhyDrvModel",
        "cpqDaPhyDrvFWRev",
        "cpqDaPhyDrvSerialNum",
        "cpqDaPhyDrvFailureCode",
        "cpqDaPhyDrvStatus",
        "cpqDaPhyDrvBusNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is `failed(3)`, `predictiveFailure(4)`, `ssdWearOut(8)`, or `notAuthenticated(9)`, replace the drive."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQIDA-MIB

    Published definition
    cpqDa7PhyDrvStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
                         cpqDaPhyDrvCntlrIndex, cpqDaPhyDrvIndex,
                         cpqDaPhyDrvLocationString, cpqDaPhyDrvType,
                         cpqDaPhyDrvModel, cpqDaPhyDrvFWRev, cpqDaPhyDrvSerialNum,
                         cpqDaPhyDrvFailureCode, cpqDaPhyDrvStatus,
                         cpqDaPhyDrvBusNumber }
            DESCRIPTION
                "Physical Drive Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of a drive array physical drive.  The variable
                 cpaDaPhyDrvStatus indicates the current physical drive status.
    
                 User Action: If cpaDaPhyDrvStatus is `failed(3)`,
                 `predictiveFailure(4)`, `ssdWearOut(8)`, or `notAuthenticated(9)`,
                 replace the drive."
    
            --#TYPE "Physical Drive Status Change (3046)"
            --#SUMMARY "Physical drive status is now %d for drive at location %s connected to controller in %s."
            --#ARGUMENTS {11, 5, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY STORAGE
            --#ACTION "If the physical drive status is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)', replace the drive."
            
            ::= 3046
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA-MIB

    Related source files and packages:


    Source location: CPQIDA-MIB::cpqDa7PhyDrvStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.378273+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.8010 cpqSs3TempDegraded00
1.3.6.1.4.1.232.0.8011 cpqSs3TempOk00
1.3.6.1.4.1.232.0.8012 cpqSs3SidePanelInPlace00
1.3.6.1.4.1.232.0.8013 cpqSs3SidePanelRemoved00
1.3.6.1.4.1.232.0.8014 cpqSs3PwrSupplyDegraded00
1.3.6.1.4.1.232.0.8015 cpqSs4PwrSupplyDegraded00
1.3.6.1.4.1.232.0.8016 cpqSsExFanStatusChange00
1.3.6.1.4.1.232.0.8017 cpqSsExPowerSupplyStatusChange00
1.3.6.1.4.1.232.0.8018 cpqSsExPowerSupplyUpsStatusChange00
1.3.6.1.4.1.232.0.8019 cpqSsExTempSensorStatusChange00
1.3.6.1.4.1.232.0.8020 cpqSsEx2FanStatusChange00
1.3.6.1.4.1.232.0.8021 cpqSsEx2PowerSupplyStatusChange00
1.3.6.1.4.1.232.0.8022 cpqSsExBackplaneFanStatusChange00
1.3.6.1.4.1.232.0.8023 cpqSsExBackplaneTempStatusChange00
1.3.6.1.4.1.232.0.8024 cpqSsExBackplanePowerSupplyStatusChange00
1.3.6.1.4.1.232.0.8025 cpqSsExRecoveryServerStatusChange00
1.3.6.1.4.1.232.0.8026 cpqSs5FanStatusChange00
1.3.6.1.4.1.232.0.8027 cpqSs5TempStatusChange00
1.3.6.1.4.1.232.0.8028 cpqSs5PwrSupplyStatusChange00
1.3.6.1.4.1.232.0.8029 cpqSs6FanStatusChange00
1.3.6.1.4.1.232.0.8030 cpqSs6TempStatusChange00
1.3.6.1.4.1.232.0.8031 cpqSs6PwrSupplyStatusChange00
1.3.6.1.4.1.232.0.8032 cpqSsConnectionStatusChange00
1.3.6.1.4.1.232.0.8033 cpqSsGSIStatusChange00
1.3.6.1.4.1.232.0.9001 cpqSm2ServerReset00
1.3.6.1.4.1.232.0.9002 cpqSm2ServerPowerOutage00
1.3.6.1.4.1.232.0.9003 cpqSm2UnauthorizedLoginAttempts00
1.3.6.1.4.1.232.0.9004 cpqSm2BatteryFailed00
1.3.6.1.4.1.232.0.9005 cpqSm2SelfTestError00
1.3.6.1.4.1.232.0.9006 cpqSm2InterfaceError00
1.3.6.1.4.1.232.0.9007 cpqSm2BatteryDisconnected00
1.3.6.1.4.1.232.0.9008 cpqSm2KeyboardCableDisconnected00
1.3.6.1.4.1.232.0.9009 cpqSm2MouseCableDisconnected00
1.3.6.1.4.1.232.0.9010 cpqSm2ExternalPowerCableDisconnected00
1.3.6.1.4.1.232.0.9011 cpqSm2LogsFull00
1.3.6.1.4.1.232.0.9012 cpqSm2SecurityOverrideEngaged00
1.3.6.1.4.1.232.0.9013 cpqSm2SecurityOverrideDisengaged00
1.3.6.1.4.1.232.0.9014 cpqSm2ServerFatalError00
1.3.6.1.4.1.232.0.9015 cpqSm2NicLinkDown00
1.3.6.1.4.1.232.0.9016 cpqSm2NicLinkUp00
1.3.6.1.4.1.232.0.9017 cpqSm2ServerPowerOn00
1.3.6.1.4.1.232.0.9018 cpqSm2ServerPowerOff00
1.3.6.1.4.1.232.0.9019 cpqSm2ServerPowerOnFailure00
1.3.6.1.4.1.232.0.9020 cpqSm2IrsCommFailure00
1.3.6.1.4.1.232.0.9021 cpqSm2FirmwareValidationScanFailed00
1.3.6.1.4.1.232.0.9022 cpqSm2FirmwareValidationScanErrorRepaired00
1.3.6.1.4.1.232.0.9023 cpqSm2FirmwareValidationAutoRepairFailed00
1.3.6.1.4.1.232.0.9024 cpqSm2AutoShutdownInitiated00
1.3.6.1.4.1.232.0.9025 cpqSm2AutoShutdownCancelled00
1.3.6.1.4.1.232.0.9026 cpqSm2FwUpdateUploadFailed00