Reference record for OID 1.3.6.1.4.1.232.0.3049

Parent
1.3.6.1.4.1.232.0 (0)
Node code
3049
Node name
cpqDaPhyDrvSSDWearStatusChange
Numeric OID
1.3.6.1.4.1.232.0.3049
URN notation
urn:oid:1.3.6.1.4.1.232.0.3049
ASN.1 notation

{1 3 6 1 4 1 232 0 3049}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqDaPhyDrvSSDWearStatusChange(3049)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/3049
  • /ISO/Identified-Organization/6/1/4/1/232/0/3049
  • /ISO/3/6/1/4/1/232/0/3049
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqDaPhyDrvSSDWearStatusChange
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqDaPhyDrvSSDWearStatusChange
  • Additional combinations skipped.

Descriptions

cpqDaPhyDrvSSDWearStatusChange — HPE networking MIB copies (LibreNMS/Observium Community)

Solid State Disk Wear Status Change. This trap signifies that the agent has detected a change in the SSD wear status of a drive array physical drive. The variable cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status. User Action: If cpqDaPhyDrvSSDWearStatus is `ssdWearOut(6)`, replace the drive.

cpqDaPhyDrvSSDWearStatusChange — HPE networking MIB copies (LibreNMS/Observium Community)

Solid State Disk Wear Status Change. This trap signifies that the agent has detected a change in the SSD wear status of a drive array physical drive. The variable cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status. User Action: If cpqDaPhyDrvSSDWearStatus is 'ssdWearOut(6)', replace the drive.

Source records

cpqDaPhyDrvSSDWearStatusChange

Status in source: unspecified.

Names: cpqDaPhyDrvSSDWearStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqDaPhyDrvSSDWearStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqDaCntlrHwLocation",
    ",",
    "cpqDaPhyDrvCntlrIndex",
    ",",
    "cpqDaPhyDrvIndex",
    ",",
    "cpqDaPhyDrvLocationString",
    ",",
    "cpqDaPhyDrvType",
    ",",
    "cpqDaPhyDrvModel",
    ",",
    "cpqDaPhyDrvFWRev",
    ",",
    "cpqDaPhyDrvSerialNum",
    ",",
    "cpqDaPhyDrvSSDWearStatus",
    "}",
    "DESCRIPTION",
    "\"Solid State Disk Wear Status Change. This trap signifies that the agent has detected a change in the SSD wear status of a drive array physical drive. The variable cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status. User Action: If cpqDaPhyDrvSSDWearStatus is `ssdWearOut(6)`, replace the drive.\"",
    "::=",
    "3049"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqDaCntlrHwLocation",
        "cpqDaPhyDrvCntlrIndex",
        "cpqDaPhyDrvIndex",
        "cpqDaPhyDrvLocationString",
        "cpqDaPhyDrvType",
        "cpqDaPhyDrvModel",
        "cpqDaPhyDrvFWRev",
        "cpqDaPhyDrvSerialNum",
        "cpqDaPhyDrvSSDWearStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Solid State Disk Wear Status Change. This trap signifies that the agent has detected a change in the SSD wear status of a drive array physical drive. The variable cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status. User Action: If cpqDaPhyDrvSSDWearStatus is `ssdWearOut(6)`, replace the drive."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQIDA-MIB

    Published definition
    cpqDaPhyDrvSSDWearStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
                         cpqDaPhyDrvCntlrIndex, cpqDaPhyDrvIndex,
                         cpqDaPhyDrvLocationString, cpqDaPhyDrvType,
                         cpqDaPhyDrvModel, cpqDaPhyDrvFWRev, cpqDaPhyDrvSerialNum,
                         cpqDaPhyDrvSSDWearStatus}
            DESCRIPTION
                "Solid State Disk Wear Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 SSD wear status of a drive array physical drive.  The variable
                 cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status.
    
                 User Action: If cpqDaPhyDrvSSDWearStatus is `ssdWearOut(6)`, replace
                 the drive."
    
            --#TYPE "Solid State Disk Wear Status Change (3049)"
            --#SUMMARY "Solid state disk wear status is now %d for drive at location %s connected to controller in %s."
            --#ARGUMENTS {10, 5, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY STORAGE
            --#ACTION "If the SSD wear status is 'ssdWearOut(6)', replace the drive."
            
            ::= 3049
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA-MIB

    Related source files and packages:


    Source location: CPQIDA-MIB::cpqDaPhyDrvSSDWearStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.378273+00:00.

cpqDaPhyDrvSSDWearStatusChange

Status in source: unspecified.

Names: cpqDaPhyDrvSSDWearStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqDaPhyDrvSSDWearStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqDaCntlrHwLocation",
    ",",
    "cpqDaPhyDrvCntlrIndex",
    ",",
    "cpqDaPhyDrvIndex",
    ",",
    "cpqDaPhyDrvLocationString",
    ",",
    "cpqDaPhyDrvType",
    ",",
    "cpqDaPhyDrvModel",
    ",",
    "cpqDaPhyDrvFWRev",
    ",",
    "cpqDaPhyDrvSerialNum",
    ",",
    "cpqDaPhyDrvSSDWearStatus",
    "}",
    "DESCRIPTION",
    "\"Solid State Disk Wear Status Change. This trap signifies that the agent has detected a change in the SSD wear status of a drive array physical drive. The variable cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status. User Action: If cpqDaPhyDrvSSDWearStatus is 'ssdWearOut(6)', replace the drive.\"",
    "::=",
    "3049"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqDaCntlrHwLocation",
        "cpqDaPhyDrvCntlrIndex",
        "cpqDaPhyDrvIndex",
        "cpqDaPhyDrvLocationString",
        "cpqDaPhyDrvType",
        "cpqDaPhyDrvModel",
        "cpqDaPhyDrvFWRev",
        "cpqDaPhyDrvSerialNum",
        "cpqDaPhyDrvSSDWearStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Solid State Disk Wear Status Change. This trap signifies that the agent has detected a change in the SSD wear status of a drive array physical drive. The variable cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status. User Action: If cpqDaPhyDrvSSDWearStatus is 'ssdWearOut(6)', replace the drive."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQIDA-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQIDA-MIB

    Published definition
    cpqDaPhyDrvSSDWearStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
                         cpqDaPhyDrvCntlrIndex, cpqDaPhyDrvIndex,
                         cpqDaPhyDrvLocationString, cpqDaPhyDrvType,
                         cpqDaPhyDrvModel, cpqDaPhyDrvFWRev, cpqDaPhyDrvSerialNum,
                         cpqDaPhyDrvSSDWearStatus}
            DESCRIPTION
                "Solid State Disk Wear Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 SSD wear status of a drive array physical drive.  The variable
                 cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status.
    
                 User Action: If cpqDaPhyDrvSSDWearStatus is 'ssdWearOut(6)', replace
                 the drive."
    
            --#TYPE "Solid State Disk Wear Status Change (3049)"
            --#SUMMARY "Solid state disk wear status is now %d for drive at location %s connected to controller in %s."
            --#ARGUMENTS {10, 5, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY STORAGE
            --#ACTION "If the SSD wear status is 'ssdWearOut(6)', replace the drive."
            
            ::= 3049
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA-MIB

    Related source files and packages:


    Source location: CPQIDA-MIB::cpqDaPhyDrvSSDWearStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.136420+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.6032 cpqHe3FltTolPowerRedundancyLost00
1.3.6.1.4.1.232.0.6033 cpqHe3FltTolPowerSupplyInserted00
1.3.6.1.4.1.232.0.6034 cpqHe3FltTolPowerSupplyRemoved00
1.3.6.1.4.1.232.0.6035 cpqHe3FltTolFanDegraded00
1.3.6.1.4.1.232.0.6036 cpqHe3FltTolFanFailed00
1.3.6.1.4.1.232.0.6037 cpqHe3FltTolFanRedundancyLost00
1.3.6.1.4.1.232.0.6038 cpqHe3FltTolFanInserted00
1.3.6.1.4.1.232.0.6039 cpqHe3FltTolFanRemoved00
1.3.6.1.4.1.232.0.6040 cpqHe3TemperatureFailed00
1.3.6.1.4.1.232.0.6041 cpqHe3TemperatureDegraded00
1.3.6.1.4.1.232.0.6042 cpqHe3TemperatureOk00
1.3.6.1.4.1.232.0.6043 cpqHe3PowerConverterDegraded00
1.3.6.1.4.1.232.0.6044 cpqHe3PowerConverterFailed00
1.3.6.1.4.1.232.0.6045 cpqHe3PowerConverterRedundancyLost00
1.3.6.1.4.1.232.0.6046 cpqHe3CacheAccelParityError00
1.3.6.1.4.1.232.0.6047 cpqHeResilientMemOnlineSpareEngaged00
1.3.6.1.4.1.232.0.6048 cpqHe4FltTolPowerSupplyOk00
1.3.6.1.4.1.232.0.6049 cpqHe4FltTolPowerSupplyDegraded00
1.3.6.1.4.1.232.0.6050 cpqHe4FltTolPowerSupplyFailed00
1.3.6.1.4.1.232.0.6051 cpqHeResilientMemMirroredMemoryEngaged00
1.3.6.1.4.1.232.0.6052 cpqHeResilientAdvancedECCMemoryEngaged00
1.3.6.1.4.1.232.0.6053 cpqHeResilientMemXorMemoryEngaged00
1.3.6.1.4.1.232.0.6054 cpqHe3FltTolPowerRedundancyRestored00
1.3.6.1.4.1.232.0.6055 cpqHe3FltTolFanRedundancyRestored00
1.3.6.1.4.1.232.0.6056 cpqHe4CorrMemReplaceMemModule00
1.3.6.1.4.1.232.0.6057 cpqHeResMemBoardRemoved00
1.3.6.1.4.1.232.0.6058 cpqHeResMemBoardInserted00
1.3.6.1.4.1.232.0.6059 cpqHeResMemBoardBusError00
1.3.6.1.4.1.232.0.6060 cpqHeEventOccurred00
1.3.6.1.4.1.232.0.6061 cpqHeManagementProcInReset00
1.3.6.1.4.1.232.0.6062 cpqHeManagementProcReady00
1.3.6.1.4.1.232.0.6063 cpqHeManagementProcFailedReset00
1.3.6.1.4.1.232.0.6064 cpqHe5CorrMemReplaceMemModule00
1.3.6.1.4.1.232.0.6065 cpqHe5ResMemBoardRemoved00
1.3.6.1.4.1.232.0.6066 cpqHe5ResMemBoardInserted00
1.3.6.1.4.1.232.0.6067 cpqHe5ResMemBoardBusError00
1.3.6.1.4.1.232.0.6068 cpqHeResilientMemLockStepMemoryEngaged00
1.3.6.1.4.1.232.0.6069 cpqHe4FltTolPowerSupplyACpowerloss00
1.3.6.1.4.1.232.0.6070 cpqHeSysBatteryFailed00
1.3.6.1.4.1.232.0.6071 cpqHeSysBatteryRemoved00
1.3.6.1.4.1.232.0.6072 cpqHeSysPwrAllocationNotOptimized00
1.3.6.1.4.1.232.0.6073 cpqHeSysPwrOnDenied00
1.3.6.1.4.1.232.0.6074 cpqHePowerFailureError00
1.3.6.1.4.1.232.0.6075 cpqHeInterlockFailureError00
1.3.6.1.4.1.232.0.6076 cpqHeNvdimmBackupError00
1.3.6.1.4.1.232.0.6077 cpqHeNvdimmRestoreError00
1.3.6.1.4.1.232.0.6078 cpqHeNvdimmUncorrectableMemoryError00
1.3.6.1.4.1.232.0.6079 cpqHeNvdimmBackupPowerError00
1.3.6.1.4.1.232.0.6080 cpqHeNvdimmNVDIMMControllerError00
1.3.6.1.4.1.232.0.6081 cpqHeNvdimmEraseError00