Reference record for OID 1.3.6.1.4.1.232.0.5012

Parent
1.3.6.1.4.1.232.0 (0)
Node code
5012
Node name
cpqTape3LibraryDegraded
Numeric OID
1.3.6.1.4.1.232.0.5012
URN notation
urn:oid:1.3.6.1.4.1.232.0.5012
ASN.1 notation

{1 3 6 1 4 1 232 0 5012}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqTape3LibraryDegraded(5012)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqTape3LibraryDegraded(5012)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/5012
  • /ISO/Identified-Organization/6/1/4/1/232/0/5012
  • /ISO/3/6/1/4/1/232/0/5012
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqTape3LibraryDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqTape3LibraryDegraded
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqTape3LibraryDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqTape3LibraryDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqTape3LibraryDegraded
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqTape3LibraryDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqTape3LibraryDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqTape3LibraryDegraded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqTape3LibraryDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqTape3LibraryDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqTape3LibraryDegraded
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqTape3LibraryDegraded
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqTape3LibraryDegraded
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqTape3LibraryDegraded
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqTape3LibraryDegraded
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqTape3LibraryDegraded
  • Additional combinations skipped.

Descriptions

cpqTape3LibraryDegraded — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Tape Library Degraded The agent has detected that an autoloader unit is in a degraded condition.

cpqTape3LibraryDegraded — Circitor, MIBdepot

Tape Library Degraded The Insight Agent has detected that an autoloader unit is in a degraded condition.

Source records

cpqTape3LibraryDegraded

Status in source: unspecified.

Names: cpqTape3LibraryDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqTape3LibraryDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqTapeLibrarySerialNumber",
    "}",
    "DESCRIPTION",
    "\"Tape Library Degraded The agent has detected that an autoloader unit is in a degraded condition.\"",
    "::=",
    "5012"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqTapeLibrarySerialNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "Tape Library Degraded The agent has detected that an autoloader unit is in a degraded condition."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSCSI-MIB

    Published definition
    cpqTape3LibraryDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqTapeLibrarySerialNumber }
            DESCRIPTION
               "Tape Library Degraded
    
                The agent has detected that an autoloader unit is
                in a degraded condition."
    
                  --#TYPE "Tape Library Degraded (5012)"
                  --#SUMMARY "Tape library %s is in a degraded condition."
                  --#ARGUMENTS {2}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
             ::= 5012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSCSI.MIB.txt
    Source location: CPQSCSI-MIB::cpqTape3LibraryDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.788596+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSCSI-MIB

    Published definition
    cpqTape3LibraryDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqTapeLibrarySerialNumber }
            DESCRIPTION
               "Tape Library Degraded
    
                The agent has detected that an autoloader unit is
                in a degraded condition."
    
                  --#TYPE "Tape Library Degraded (5012)"
                  --#SUMMARY "Tape library %s is in a degraded condition."
                  --#ARGUMENTS {2}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
             ::= 5012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSCSI-MIB

    Related source files and packages:


    Source location: CPQSCSI-MIB::cpqTape3LibraryDegraded.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.127280+00:00.

cpqTape3LibraryDegraded

Status in source: unspecified.

Names: cpqTape3LibraryDegraded

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqTape3LibraryDegraded",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqTapeLibrarySerialNumber",
    "}",
    "DESCRIPTION",
    "\"Tape Library Degraded The Insight Agent has detected that an autoloader unit is in a degraded condition.\"",
    "::=",
    "5012"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqTapeLibrarySerialNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "Tape Library Degraded The Insight Agent has detected that an autoloader unit is in a degraded condition."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSCSI-MIB

    Published definition
    cpqTape3LibraryDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqTapeLibrarySerialNumber }
            DESCRIPTION
               "Tape Library Degraded
    
                The Insight Agent has detected that an autoloader unit is
                in a degraded condition."
    
                  --#TYPE "Tape Library Degraded"
                  --#SUMMARY "Tape library is in a degraded condition."
                  --#ARGUMENTS {2}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
             ::= 5012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqscsi.mib.txt
    Source location: CPQSCSI-MIB::cpqTape3LibraryDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:07.891806+00:00.

  • Preserved mibdepot archive

    Module: CPQSCSI-MIB

    Published definition
    cpqTape3LibraryDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqTapeLibrarySerialNumber }
            DESCRIPTION
               "Tape Library Degraded
    
                The Insight Agent has detected that an autoloader unit is
                in a degraded condition."
    
                  --#TYPE "Tape Library Degraded"
                  --#SUMMARY "Tape library %s is in a degraded condition."
                  --#ARGUMENTS {2}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
             ::= 5012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSCSI1.MIB.txt
    Source location: CPQSCSI-MIB::cpqTape3LibraryDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.789407+00:00.

  • Preserved mibdepot archive

    Module: CPQSCSI-MIB

    Published definition
    cpqTape3LibraryDegraded TRAP-TYPE 
            ENTERPRISE compaq 
            VARIABLES  { sysName, cpqHoTrapFlags, cpqTapeLibrarySerialNumber } 
            DESCRIPTION 
               "Tape Library Degraded 
     
                The Insight Agent has detected that an autoloader unit is 
                in a degraded condition." 
     
                  --#TYPE "Tape Library Degraded" 
                  --#SUMMARY "Tape library is in a degraded condition." 
                  --#ARGUMENTS {2} 
                  --#SEVERITY CRITICAL 
                  --#TIMEINDEX 99 
     
             ::= 5012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Compaq-Scsi.mib.txt
    Source location: CPQSCSI-MIB::cpqTape3LibraryDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:08.810327+00:00.

  • Preserved circitor archive

    Module: CPQSCSI-MIB

    Published definition
    cpqTape3LibraryDegraded TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqTapeLibrarySerialNumber }
            DESCRIPTION
               "Tape Library Degraded
    
                The Insight Agent has detected that an autoloader unit is
                in a degraded condition."
    
                  --#TYPE "Tape Library Degraded"
                  --#SUMMARY "Tape library %s is in a degraded condition."
                  --#ARGUMENTS {2}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
             ::= 5012
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSCSI-MIB.mib
    Source location: CPQSCSI-MIB::cpqTape3LibraryDegraded.
    Source version and references

    Archived: 2026-10-19T00:22:16.799197+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.22080 cpqRackMinorWSMANTrap00
1.3.6.1.4.1.232.0.22081 cpqRackMajorWSMANTrap00
1.3.6.1.4.1.232.0.22082 cpqRackCriticalWSMANTrap00
1.3.6.1.4.1.232.0.22083 cpqRackEnclosureManagerLinkDown00
1.3.6.1.4.1.232.0.22084 cpqRackEnclosureManagerLinkUp00
1.3.6.1.4.1.232.0.22085 cpqRackErsCommFailure00
1.3.6.1.4.1.232.0.22086 cpqRackPowerSubsystemOverloadConditionRepaired00
1.3.6.1.4.1.232.0.22087 cpqRackPowerSubsystemRedundancyOk00
1.3.6.1.4.1.232.0.22088 cpqRackNetConnectorTempDegraded00
1.3.6.1.4.1.232.0.22089 cpqRackNetConnectorTempOk00
1.3.6.1.4.1.232.0.22090 cpqRackEnvironmentalLeakDetected00
1.3.6.1.4.1.232.0.22091 cpqRackEnvironmentalDoorState00
1.3.6.1.4.1.232.0.22092 cpqRackEnvironmentalAirTempSensor00
1.3.6.1.4.1.232.0.22093 cpqRackEnvironmentalControlValveStatus00
1.3.6.1.4.1.232.0.22094 cpqRackEnvironmentalWaterTempThresholdExceeded00
1.3.6.1.4.1.232.0.22095 cpqRackEnvironmentalFlowSensorStatus00
1.3.6.1.4.1.232.0.22096 cpqRackEnvironmentalWaterPressureThresholdExceeded00
1.3.6.1.4.1.232.0.22097 cpqRackEnvironmentalAutomaticRapidPowerOff00
1.3.6.1.4.1.232.0.22098 cpqRackEnvironmentalRopeLeakDetectorEvent00
1.3.6.1.4.1.232.0.22099 cpqRackEnvironmentalTemperatureThresholdExceeded00
1.3.6.1.4.1.232.0.22100 cpqRackEnvironmentalHumidityThresholdExceeded00
1.3.6.1.4.1.232.0.22101 cpqRackEnvironmentalControllerOnBoardBattery00
1.3.6.1.4.1.232.0.22102 cpqRackEnvironmentalControllerAPMCommunicationFailure00
1.3.6.1.4.1.232.0.22103 cpqRackEnvironmentalLeakDetectedCritical00
1.3.6.1.4.1.232.0.22104 cpqRackPowerSubsystemReductionModeActivate00
1.3.6.1.4.1.232.0.22105 cpqRackPowerSubsystemReductionModeDeactivate00
1.3.6.1.4.1.232.0.23001 cpqNodeTemperatureDegraded00
1.3.6.1.4.1.232.0.23002 cpqNodeTemperatureOk00
1.3.6.1.4.1.232.0.23003 cpqNodeTemperatureFailed00
1.3.6.1.4.1.232.0.23004 cpqNodeErrorEvent00
1.3.6.1.4.1.232.0.23010 cpqNodePowerOn00
1.3.6.1.4.1.232.0.23011 cpqNodePowerOff00
1.3.6.1.4.1.232.0.99999 cpqGenericUnregistered00
1.3.6.1.4.1.232.0.136001 emuEventTrapInformative00
1.3.6.1.4.1.232.0.136002 emuEventTrapNoncritical00
1.3.6.1.4.1.232.0.136003 emuEventTrapCritical00
1.3.6.1.4.1.232.0.136004 emuEventTrapUnrecoverable00
1.3.6.1.4.1.232.0.140001 cpqICAAdd00
1.3.6.1.4.1.232.0.140002 cpqICADelete00
1.3.6.1.4.1.232.0.140003 cpqICAPropertyChange00
1.3.6.1.4.1.232.0.140004 cpqICAMove00
1.3.6.1.4.1.232.0.140005 cpqICAImportRestoreStart00
1.3.6.1.4.1.232.0.140006 cpqICAImportRestoreEnd00
1.3.6.1.4.1.232.0.150001 cpqDMIIndicationInfo00
1.3.6.1.4.1.232.0.150002 cpqDMIIndicationMonitor00
1.3.6.1.4.1.232.0.150003 cpqDMIIndicationOK00
1.3.6.1.4.1.232.0.150004 cpqDMIIndicationNonCritical00
1.3.6.1.4.1.232.0.150005 cpqDMIIndicationCritical00
1.3.6.1.4.1.232.0.150006 cpqDMIIndicationNonNonRecoverable00
1.3.6.1.4.1.232.0.161001 switchFirmwareTransferred00