Reference record for OID 1.3.6.1.4.1.232.0.6024

Parent
1.3.6.1.4.1.232.0 (0)
Node code
6024
Node name
cpqHe3ThermalCpuFanOk
Numeric OID
1.3.6.1.4.1.232.0.6024
URN notation
urn:oid:1.3.6.1.4.1.232.0.6024
ASN.1 notation

{1 3 6 1 4 1 232 0 6024}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqHe3ThermalCpuFanOk(6024)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/6024
  • /ISO/Identified-Organization/6/1/4/1/232/0/6024
  • /ISO/3/6/1/4/1/232/0/6024
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqHe3ThermalCpuFanOk
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqHe3ThermalCpuFanOk
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqHe3ThermalCpuFanOk
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqHe3ThermalCpuFanOk
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqHe3ThermalCpuFanOk
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqHe3ThermalCpuFanOk
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqHe3ThermalCpuFanOk
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqHe3ThermalCpuFanOk
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqHe3ThermalCpuFanOk
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqHe3ThermalCpuFanOk
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqHe3ThermalCpuFanOk
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqHe3ThermalCpuFanOk
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqHe3ThermalCpuFanOk
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqHe3ThermalCpuFanOk
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqHe3ThermalCpuFanOk
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqHe3ThermalCpuFanOk
  • Additional combinations skipped.

Descriptions

cpqHe3ThermalCpuFanOk — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

The CPU fan status has been set to ok. Any previously non-operational processor fans have returned to normal operation.

Source records

cpqHe3ThermalCpuFanOk

Status in source: unspecified.

Names: cpqHe3ThermalCpuFanOk

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqHe3ThermalCpuFanOk",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    "}",
    "DESCRIPTION",
    "\"The CPU fan status has been set to ok. Any previously non-operational processor fans have returned to normal operation.\"",
    "::=",
    "6024"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags"
      ]
    ],
    [
      "DESCRIPTION",
      "The CPU fan status has been set to ok. Any previously non-operational processor fans have returned to normal operation."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3ThermalCpuFanOk TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "The CPU fan status has been set to ok.
    
                 Any previously non-operational processor fans have returned
                 to normal operation."
    
            --#TYPE "CPU Fan OK"
            --#SUMMARY "CPU fan is now OK."
            --#ARGUMENTS {}
            --#SEVERITY INFORMATIONAL
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6024
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqhlth.mib.txt
    Source location: CPQHLTH-MIB::cpqHe3ThermalCpuFanOk.
    Source version and references

    Archived: 2026-10-19T00:22:07.890299+00:00.

  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3ThermalCpuFanOk TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "The CPU fan status has been set to ok.
    
                 Any previously non-operational processor fans have returned
                 to normal operation."
    
            --#TYPE "CPU Fan OK (6024)"
            --#SUMMARY "CPU fan is now OK."
            --#ARGUMENTS {}
            --#SEVERITY INFORMATIONAL
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6024
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH.MIB.txt
    Source location: CPQHLTH-MIB::cpqHe3ThermalCpuFanOk.
    Source version and references

    Archived: 2026-10-19T00:22:08.777488+00:00.

  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3ThermalCpuFanOk TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "The CPU fan status has been set to ok.
    
                 Any previously non-operational processor fans have returned
                 to normal operation."
    
            --#TYPE "CPU Fan OK"
            --#SUMMARY "CPU fan is now OK."
            --#ARGUMENTS {}
            --#SEVERITY INFORMATIONAL
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6024
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH1.MIB.txt
    Source location: CPQHLTH-MIB::cpqHe3ThermalCpuFanOk.
    Source version and references

    Archived: 2026-10-19T00:22:08.778207+00:00.

  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3ThermalCpuFanOk TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "The CPU fan status has been set to ok.
    
                 Any previously non-operational processor fans have returned
                 to normal operation."
    
            --#TYPE "CPU Fan OK"
            --#SUMMARY "CPU fan is now OK."
            --#ARGUMENTS {}
            --#SEVERITY INFORMATIONAL
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6024
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Compaq-Health.mib.txt
    Source location: CPQHLTH-MIB::cpqHe3ThermalCpuFanOk.
    Source version and references

    Archived: 2026-10-19T00:22:08.798723+00:00.

  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3ThermalCpuFanOk TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "The CPU fan status has been set to ok.
    
                 Any previously non-operational processor fans have returned
                 to normal operation."
    
            --#TYPE "CPU Fan OK"
            --#SUMMARY "CPU fan is now OK."
            --#ARGUMENTS {}
            --#SEVERITY INFORMATIONAL
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6024
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqHealth.mib.txt
    Source location: CPQHLTH-MIB::cpqHe3ThermalCpuFanOk.
    Source version and references

    Archived: 2026-10-19T00:22:08.852938+00:00.

  • Preserved circitor archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3ThermalCpuFanOk TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "The CPU fan status has been set to ok.
    
                 Any previously non-operational processor fans have returned
                 to normal operation."
    
            --#TYPE "CPU Fan OK (6024)"
            --#SUMMARY "CPU fan is now OK."
            --#ARGUMENTS {}
            --#SEVERITY INFORMATIONAL
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6024
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH-MIB.mib
    Source location: CPQHLTH-MIB::cpqHe3ThermalCpuFanOk.
    Source version and references

    Archived: 2026-10-19T00:22:16.765010+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQHLTH-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3ThermalCpuFanOk TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "The CPU fan status has been set to ok.
    
                 Any previously non-operational processor fans have returned
                 to normal operation."
    
            --#TYPE "CPU Fan OK (6024)"
            --#SUMMARY "CPU fan is now OK."
            --#ARGUMENTS {}
            --#SEVERITY INFORMATIONAL
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
            --#SIMPLE_SEVERITY OK
            --#HWSTATUS_CATEGORY FAN
    
            ::= 6024
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoGUIDCanonical'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH-MIB

    Related source files and packages:


    Source location: CPQHLTH-MIB::cpqHe3ThermalCpuFanOk.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.131421+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3ThermalCpuFanOk TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "The CPU fan status has been set to ok.
    
                 Any previously non-operational processor fans have returned
                 to normal operation."
    
            --#TYPE "CPU Fan OK (6024)"
            --#SUMMARY "CPU fan is now OK."
            --#ARGUMENTS {}
            --#SEVERITY INFORMATIONAL
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY OK
            --#HWSTATUS_CATEGORY FAN
    
            ::= 6024
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoGUIDCanonical'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH-MIB

    Related source files and packages:


    Source location: CPQHLTH-MIB::cpqHe3ThermalCpuFanOk.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.153279+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.6082 cpqHeNvdimmArmingError00
1.3.6.1.4.1.232.0.6083 cpqHeNvdimmSanitizationOk00
1.3.6.1.4.1.232.0.6084 cpqHeNvdimmSanitizationError00
1.3.6.1.4.1.232.0.6085 cpqHeNvdimmControllerFirmwareError00
1.3.6.1.4.1.232.0.6086 cpqHeNvdimmErrorInterleaveOn00
1.3.6.1.4.1.232.0.6087 cpqHeNvdimmInterleaveOff00
1.3.6.1.4.1.232.0.6088 cpqHeNvdimmEventNotifyError00
1.3.6.1.4.1.232.0.6089 cpqHeNvdimmPersistencyLost00
1.3.6.1.4.1.232.0.6090 cpqHeNvdimmPersistencyRestored00
1.3.6.1.4.1.232.0.6091 cpqHeNvdimmLifecycleWarning00
1.3.6.1.4.1.232.0.6092 cpqHeNvdimmLogicalNvdimmError00
1.3.6.1.4.1.232.0.6093 cpqHeNvdimmConfigurationError00
1.3.6.1.4.1.232.0.6094 cpqHeNvdimmBatteryNotChargedwithWait00
1.3.6.1.4.1.232.0.6095 cpqHeNvdimmBatteryNotChargedwithNoWait00
1.3.6.1.4.1.232.0.6096 cpqHeDimmMemoryMapChanged00
1.3.6.1.4.1.232.0.6097 cpqHeNvdimmPersistantMemoryAddressError00
1.3.6.1.4.1.232.0.6098 cpqHeNvdimmInitializationError00
1.3.6.1.4.1.232.0.6099 cpqHePwrSupplyError00
1.3.6.1.4.1.232.0.6100 cpqHePwrSupplyErrorRepaired00
1.3.6.1.4.1.232.0.6101 cpqHeBbuError00
1.3.6.1.4.1.232.0.6102 cpqHeBbuErrorRepaired00
1.3.6.1.4.1.232.0.6103 cpqHeNoPowerSupplyDetected00
1.3.6.1.4.1.232.0.6104 cpqHePowerProtectionFault00
1.3.6.1.4.1.232.0.6105 cpqHePowerFuseDegraded00
1.3.6.1.4.1.232.0.6106 cpqHeTPMSecureEraseFailed00
1.3.6.1.4.1.232.0.6107 cpqHeSPISecureEraseFailed00
1.3.6.1.4.1.232.0.6108 cpqHePMMSecureEraseFailed00
1.3.6.1.4.1.232.0.6109 cpqHeNANDSecureEraseFailed00
1.3.6.1.4.1.232.0.6110 cpqHeSedPassphrasefail00
1.3.6.1.4.1.232.0.6111 cpqHeSedUnlockfail00
1.3.6.1.4.1.232.0.6112 cpqHePMMHealthFailure00
1.3.6.1.4.1.232.0.6113 cpqHePMMLessUsageRemainingAlert00
1.3.6.1.4.1.232.0.6114 cpqHePMMConfigErr00
1.3.6.1.4.1.232.0.6115 cpqHePMMShutdownWarning00
1.3.6.1.4.1.232.0.6116 cpqHePMMCorrErrThreshold00
1.3.6.1.4.1.232.0.6117 cpqHePMMBootStatusRegWarning00
1.3.6.1.4.1.232.0.6118 cpqHeInletAmbientPreCautionThresAlert00
1.3.6.1.4.1.232.0.6119 cpqHeCoolingModuleDegraded00
1.3.6.1.4.1.232.0.6120 cpqHeCoolingModuleFailed00
1.3.6.1.4.1.232.0.6121 cpqHeCoolingModuleRedundancyLost00
1.3.6.1.4.1.232.0.6122 cpqHeCoolingModuleRedundancyRestored00
1.3.6.1.4.1.232.0.8001 cpqSs2FanStatusChange00
1.3.6.1.4.1.232.0.8002 cpqSsTempFailed00
1.3.6.1.4.1.232.0.8003 cpqSsTempDegraded00
1.3.6.1.4.1.232.0.8004 cpqSsTempOk00
1.3.6.1.4.1.232.0.8005 cpqSsSidePanelInPlace00
1.3.6.1.4.1.232.0.8006 cpqSsSidePanelRemoved00
1.3.6.1.4.1.232.0.8007 cpqSsPwrSupplyDegraded00
1.3.6.1.4.1.232.0.8008 cpqSs3FanStatusChange00
1.3.6.1.4.1.232.0.8009 cpqSs3TempFailed00