Reference record for OID 1.3.6.1.4.1.232.0.6027

Parent
1.3.6.1.4.1.232.0 (0)
Node code
6027
Node name
cpqHe3PostError
Numeric OID
1.3.6.1.4.1.232.0.6027
URN notation
urn:oid:1.3.6.1.4.1.232.0.6027
ASN.1 notation

{1 3 6 1 4 1 232 0 6027}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqHe3PostError(6027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqHe3PostError(6027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqHe3PostError(6027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqHe3PostError(6027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqHe3PostError(6027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqHe3PostError(6027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqHe3PostError(6027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqHe3PostError(6027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqHe3PostError(6027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqHe3PostError(6027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqHe3PostError(6027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqHe3PostError(6027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqHe3PostError(6027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqHe3PostError(6027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqHe3PostError(6027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqHe3PostError(6027)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/6027
  • /ISO/Identified-Organization/6/1/4/1/232/0/6027
  • /ISO/3/6/1/4/1/232/0/6027
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqHe3PostError
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqHe3PostError
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqHe3PostError
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqHe3PostError
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqHe3PostError
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqHe3PostError
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqHe3PostError
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqHe3PostError
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqHe3PostError
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqHe3PostError
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqHe3PostError
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqHe3PostError
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqHe3PostError
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqHe3PostError
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqHe3PostError
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqHe3PostError
  • Additional combinations skipped.

Descriptions

cpqHe3PostError — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process. Details of the POST error messages can be found in Integrated Management Log

cpqHe3PostError — HPE networking MIB copies (LibreNMS/Observium Community)

One or more POST/UEFI errors occurred. Power On Self-Test (POST) errors occur during the server restart process. UEFI errors occur during server boot time and run time. Details of the POST/UEFI error messages can be found in Integrated Management Log.

cpqHe3PostError — MIBdepot

One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process.

Source records

cpqHe3PostError

Status in source: unspecified.

Names: cpqHe3PostError

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqHe3PostError",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    "}",
    "DESCRIPTION",
    "\"One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process. Details of the POST error messages can be found in Integrated Management Log \"",
    "::=",
    "6027"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags"
      ]
    ],
    [
      "DESCRIPTION",
      "One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process. Details of the POST error messages can be found in Integrated Management Log"
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3PostError TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "One or more POST errors occurred.
    
                 Power On Self-Test (POST) errors occur during the server
                 restart process. Details of the POST error messages can 
                 be found in Integrated Management Log "
    
            --#TYPE "POST Errors Occurred (6027)"
            --#SUMMARY "Errors occurred during server restart."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6027
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH.MIB.txt
    Source location: CPQHLTH-MIB::cpqHe3PostError.
    Source version and references

    Archived: 2026-10-19T00:22:08.777488+00:00.

  • Preserved circitor archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3PostError TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "One or more POST errors occurred.
    
                 Power On Self-Test (POST) errors occur during the server
                 restart process. Details of the POST error messages can 
                 be found in Integrated Management Log "
    
            --#TYPE "POST Errors Occurred (6027)"
            --#SUMMARY "Errors occurred during server restart."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6027
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH-MIB.mib
    Source location: CPQHLTH-MIB::cpqHe3PostError.
    Source version and references

    Archived: 2026-10-19T00:22:16.765010+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQHLTH-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3PostError TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "One or more POST errors occurred.
    
                 Power On Self-Test (POST) errors occur during the server
                 restart process. Details of the POST error messages can
                 be found in Integrated Management Log "
    
            --#TYPE "POST Errors Occurred (6027)"
            --#SUMMARY "Power on self-test errors occurred during server restart."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY LOGS
            --#ACTION "Refer to the Integrated Management Log for details on the Power on self-test error."
            
            ::= 6027
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoGUIDCanonical'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH-MIB

    Related source files and packages:


    Source location: CPQHLTH-MIB::cpqHe3PostError.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.131421+00:00.

cpqHe3PostError

Status in source: unspecified.

Names: cpqHe3PostError

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqHe3PostError",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    "}",
    "DESCRIPTION",
    "\"One or more POST/UEFI errors occurred. Power On Self-Test (POST) errors occur during the server restart process. UEFI errors occur during server boot time and run time. Details of the POST/UEFI error messages can be found in Integrated Management Log.\"",
    "::=",
    "6027"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags"
      ]
    ],
    [
      "DESCRIPTION",
      "One or more POST/UEFI errors occurred. Power On Self-Test (POST) errors occur during the server restart process. UEFI errors occur during server boot time and run time. Details of the POST/UEFI error messages can be found in Integrated Management Log."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3PostError TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "One or more POST/UEFI errors occurred.
    
                 Power On Self-Test (POST) errors occur during the server
                 restart process. UEFI errors occur during server boot time and run time. 
                 Details of the POST/UEFI error messages can be found in Integrated Management Log."
    
            --#TYPE "POST Errors Occurred (6027)"
            --#SUMMARY "Power On Self Test (POST)/UEFI errors occurred during server restart."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY MAJOR
            --#HWSTATUS_CATEGORY LOGS
            --#ACTION "Refer to the Integrated Management Log for details on the Power On Self Test (POST)/UEFI error."
            ::= 6027
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoGUIDCanonical'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH-MIB

    Related source files and packages:


    Source location: CPQHLTH-MIB::cpqHe3PostError.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.153279+00:00.

cpqHe3PostError

Status in source: unspecified.

Names: cpqHe3PostError

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqHe3PostError",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    "}",
    "DESCRIPTION",
    "\"One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process. \"",
    "::=",
    "6027"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags"
      ]
    ],
    [
      "DESCRIPTION",
      "One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3PostError TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "One or more POST errors occurred.
    
                 Power On Self-Test (POST) errors occur during the server
                 restart process.  "
    
            --#TYPE "POST Errors Occurred"
            --#SUMMARY "Errors occurred during server restart."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6027
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqhlth.mib.txt
    Source location: CPQHLTH-MIB::cpqHe3PostError.
    Source version and references

    Archived: 2026-10-19T00:22:07.890299+00:00.

  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3PostError TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "One or more POST errors occurred.
    
                 Power On Self-Test (POST) errors occur during the server
                 restart process.  "
    
            --#TYPE "POST Errors Occurred"
            --#SUMMARY "Errors occurred during server restart."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6027
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH1.MIB.txt
    Source location: CPQHLTH-MIB::cpqHe3PostError.
    Source version and references

    Archived: 2026-10-19T00:22:08.778207+00:00.

  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3PostError TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "One or more POST errors occurred.
    
                 Power On Self-Test (POST) errors occur during the server
                 restart process.  "
    
            --#TYPE "POST Errors Occurred"
            --#SUMMARY "Errors occurred during server restart."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6027
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Compaq-Health.mib.txt
    Source location: CPQHLTH-MIB::cpqHe3PostError.
    Source version and references

    Archived: 2026-10-19T00:22:08.798723+00:00.

  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3PostError TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags }
            DESCRIPTION
                "One or more POST errors occurred.
    
                 Power On Self-Test (POST) errors occur during the server
                 restart process.  "
    
            --#TYPE "POST Errors Occurred"
            --#SUMMARY "Errors occurred during server restart."
            --#ARGUMENTS {}
            --#SEVERITY MINOR
            --#TIMEINDEX 99
            --#STATE OPERATIONAL
    
            ::= 6027
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqHealth.mib.txt
    Source location: CPQHLTH-MIB::cpqHe3PostError.
    Source version and references

    Archived: 2026-10-19T00:22:08.852938+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.5006 cpqScsi3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5007 cpqTape3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5008 cpqTape3PhyDrvCleaningRequired00
1.3.6.1.4.1.232.0.5009 cpqTape3PhyDrvCleanTapeReplace00
1.3.6.1.4.1.232.0.5010 cpqTape3LibraryFailed00
1.3.6.1.4.1.232.0.5011 cpqTape3LibraryOkay00
1.3.6.1.4.1.232.0.5012 cpqTape3LibraryDegraded00
1.3.6.1.4.1.232.0.5013 cpqTape3LibraryDoorOpen00
1.3.6.1.4.1.232.0.5014 cpqTape3LibraryDoorClosed00
1.3.6.1.4.1.232.0.5015 cpqScsiCdLibraryStatusChange00
1.3.6.1.4.1.232.0.5016 cpqTape4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5017 cpqScsi4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5018 cpqTapeLibraryStatusChange00
1.3.6.1.4.1.232.0.5019 cpqTape5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5020 cpqScsi5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5021 cpqScsi3LogDrvStatusChange00
1.3.6.1.4.1.232.0.5022 cpqSasPhyDrvStatusChange00
1.3.6.1.4.1.232.0.5023 cpqSasLogDrvStatusChange00
1.3.6.1.4.1.232.0.5025 cpqSas2TapeDrvStatusChange00
1.3.6.1.4.1.232.0.5026 cpqSasPhyDrvSSDWearStatusChange00
1.3.6.1.4.1.232.0.6001 cpqHe2CorrectableMemoryError00
1.3.6.1.4.1.232.0.6002 cpqHe2CorrectableMemoryLogDisabled00
1.3.6.1.4.1.232.0.6003 cpqHeThermalTempFailed00
1.3.6.1.4.1.232.0.6004 cpqHeThermalTempDegraded00
1.3.6.1.4.1.232.0.6005 cpqHeThermalTempOk00
1.3.6.1.4.1.232.0.6006 cpqHeThermalSystemFanFailed00
1.3.6.1.4.1.232.0.6007 cpqHeThermalSystemFanDegraded00
1.3.6.1.4.1.232.0.6008 cpqHeThermalSystemFanOk00
1.3.6.1.4.1.232.0.6009 cpqHeThermalCpuFanFailed00
1.3.6.1.4.1.232.0.6010 cpqHeThermalCpuFanOk00
1.3.6.1.4.1.232.0.6011 cpqHeAsrConfirmation00
1.3.6.1.4.1.232.0.6012 cpqHeThermalConfirmation00
1.3.6.1.4.1.232.0.6013 cpqHePostError00
1.3.6.1.4.1.232.0.6014 cpqHeFltTolPwrSupplyDegraded00
1.3.6.1.4.1.232.0.6015 cpqHe3CorrectableMemoryError00
1.3.6.1.4.1.232.0.6016 cpqHe3CorrectableMemoryLogDisabled00
1.3.6.1.4.1.232.0.6017 cpqHe3ThermalTempFailed00
1.3.6.1.4.1.232.0.6018 cpqHe3ThermalTempDegraded00
1.3.6.1.4.1.232.0.6019 cpqHe3ThermalTempOk00
1.3.6.1.4.1.232.0.6020 cpqHe3ThermalSystemFanFailed00
1.3.6.1.4.1.232.0.6021 cpqHe3ThermalSystemFanDegraded00
1.3.6.1.4.1.232.0.6022 cpqHe3ThermalSystemFanOk00
1.3.6.1.4.1.232.0.6023 cpqHe3ThermalCpuFanFailed00
1.3.6.1.4.1.232.0.6024 cpqHe3ThermalCpuFanOk00
1.3.6.1.4.1.232.0.6025 cpqHe3AsrConfirmation00
1.3.6.1.4.1.232.0.6026 cpqHe3ThermalConfirmation00
1.3.6.1.4.1.232.0.6028 cpqHe3FltTolPwrSupplyDegraded00
1.3.6.1.4.1.232.0.6029 cpqHe3CorrMemReplaceMemModule00
1.3.6.1.4.1.232.0.6030 cpqHe3FltTolPowerSupplyDegraded00
1.3.6.1.4.1.232.0.6031 cpqHe3FltTolPowerSupplyFailed00