Reference record for OID 1.3.6.1.4.1.232.0.6040

Parent
1.3.6.1.4.1.232.0 (0)
Node code
6040
Node name
cpqHe3TemperatureFailed
Numeric OID
1.3.6.1.4.1.232.0.6040
URN notation
urn:oid:1.3.6.1.4.1.232.0.6040
ASN.1 notation

{1 3 6 1 4 1 232 0 6040}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqHe3TemperatureFailed(6040)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqHe3TemperatureFailed(6040)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/6040
  • /ISO/Identified-Organization/6/1/4/1/232/0/6040
  • /ISO/3/6/1/4/1/232/0/6040
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqHe3TemperatureFailed
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqHe3TemperatureFailed
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqHe3TemperatureFailed
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqHe3TemperatureFailed
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqHe3TemperatureFailed
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqHe3TemperatureFailed
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqHe3TemperatureFailed
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqHe3TemperatureFailed
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqHe3TemperatureFailed
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqHe3TemperatureFailed
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqHe3TemperatureFailed
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqHe3TemperatureFailed
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqHe3TemperatureFailed
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqHe3TemperatureFailed
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqHe3TemperatureFailed
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqHe3TemperatureFailed
  • Additional combinations skipped.

Descriptions

cpqHe3TemperatureFailed — MIBdepot

The tempaerature status has been set to failed in the specified chassis and location. The system will be shutdown due to this condition.

cpqHe3TemperatureFailed — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

The temperature status has been set to failed in the specified chassis and location. The system will be shutdown due to this condition.

Source records

cpqHe3TemperatureFailed

Status in source: unspecified.

Names: cpqHe3TemperatureFailed

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqHe3TemperatureFailed",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqHeTemperatureChassis",
    ",",
    "cpqHeTemperatureLocale",
    "}",
    "DESCRIPTION",
    "\"The tempaerature status has been set to failed in the specified chassis and location. The system will be shutdown due to this condition.\"",
    "::=",
    "6040"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqHeTemperatureChassis",
        "cpqHeTemperatureLocale"
      ]
    ],
    [
      "DESCRIPTION",
      "The tempaerature status has been set to failed in the specified chassis and location. The system will be shutdown due to this condition."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3TemperatureFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqHeTemperatureChassis,
                         cpqHeTemperatureLocale }
            DESCRIPTION
                "The tempaerature status has been set to failed in the
                specified chassis and location.
    
                The system will be shutdown due to this condition."
    
            --#TYPE "Thermal Failure"
            --#SUMMARY "Temperature Exceeded on Chassis %d, Location %d."
            --#ARGUMENTS {2, 3}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE  DEGRADED
    
            ::= 6040
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqhlth.mib.txt
    Source location: CPQHLTH-MIB::cpqHe3TemperatureFailed.
    Source version and references

    Archived: 2026-10-19T00:22:07.890299+00:00.

  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3TemperatureFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqHeTemperatureChassis,
                         cpqHeTemperatureLocale }
            DESCRIPTION
                "The tempaerature status has been set to failed in the
                specified chassis and location.
    
                The system will be shutdown due to this condition."
    
            --#TYPE "Thermal Failure"
            --#SUMMARY "Temperature Exceeded on Chassis %d, Location %d."
            --#ARGUMENTS {2, 3}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE  DEGRADED
    
            ::= 6040
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Compaq-Health.mib.txt
    Source location: CPQHLTH-MIB::cpqHe3TemperatureFailed.
    Source version and references

    Archived: 2026-10-19T00:22:08.798723+00:00.

  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3TemperatureFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqHeTemperatureChassis,
                         cpqHeTemperatureLocale }
            DESCRIPTION
                "The tempaerature status has been set to failed in the
                specified chassis and location.
    
                The system will be shutdown due to this condition."
    
            --#TYPE "Thermal Failure"
            --#SUMMARY "Temperature Exceeded on Chassis %d, Location %d."
            --#ARGUMENTS {2, 3}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE  DEGRADED
    
            ::= 6040
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqHealth.mib.txt
    Source location: CPQHLTH-MIB::cpqHe3TemperatureFailed.
    Source version and references

    Archived: 2026-10-19T00:22:08.852938+00:00.

cpqHe3TemperatureFailed

Status in source: unspecified.

Names: cpqHe3TemperatureFailed

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqHe3TemperatureFailed",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqHeTemperatureChassis",
    ",",
    "cpqHeTemperatureLocale",
    "}",
    "DESCRIPTION",
    "\"The temperature status has been set to failed in the specified chassis and location. The system will be shutdown due to this condition.\"",
    "::=",
    "6040"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqHeTemperatureChassis",
        "cpqHeTemperatureLocale"
      ]
    ],
    [
      "DESCRIPTION",
      "The temperature status has been set to failed in the specified chassis and location. The system will be shutdown due to this condition."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3TemperatureFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqHeTemperatureChassis,
                         cpqHeTemperatureLocale }
            DESCRIPTION
                "The temperature status has been set to failed in the
                specified chassis and location.
    
                The system will be shutdown due to this condition."
    
            --#TYPE "Thermal Failure (6040)"
            --#SUMMARY "Temperature Exceeded on Chassis %d, Location %d."
            --#ARGUMENTS {2, 3}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE  DEGRADED
    
            ::= 6040
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH.MIB.txt
    Source location: CPQHLTH-MIB::cpqHe3TemperatureFailed.
    Source version and references

    Archived: 2026-10-19T00:22:08.777488+00:00.

  • Preserved mibdepot archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3TemperatureFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqHeTemperatureChassis,
                         cpqHeTemperatureLocale }
            DESCRIPTION
                "The temperature status has been set to failed in the
                specified chassis and location.
    
                The system will be shutdown due to this condition."
    
            --#TYPE "Thermal Failure"
            --#SUMMARY "Temperature Exceeded on Chassis %d, Location %d."
            --#ARGUMENTS {2, 3}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE  DEGRADED
    
            ::= 6040
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH1.MIB.txt
    Source location: CPQHLTH-MIB::cpqHe3TemperatureFailed.
    Source version and references

    Archived: 2026-10-19T00:22:08.778207+00:00.

  • Preserved circitor archive

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3TemperatureFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqHeTemperatureChassis,
                         cpqHeTemperatureLocale }
            DESCRIPTION
                "The temperature status has been set to failed in the
                specified chassis and location.
    
                The system will be shutdown due to this condition."
    
            --#TYPE "Thermal Failure (6040)"
            --#SUMMARY "Temperature Exceeded on Chassis %d, Location %d."
            --#ARGUMENTS {2, 3}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE  DEGRADED
    
            ::= 6040
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH-MIB.mib
    Source location: CPQHLTH-MIB::cpqHe3TemperatureFailed.
    Source version and references

    Archived: 2026-10-19T00:22:16.765010+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQHLTH-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3TemperatureFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqHeTemperatureChassis,
                         cpqHeTemperatureLocale }
            DESCRIPTION
                "The temperature status has been set to failed in the
                specified chassis and location.
    
                The system will be shutdown due to this condition."
    
            --#TYPE "Thermal Failure (6040)"
            --#SUMMARY "Temperature exceeded on chassis %d, location %d."
            --#ARGUMENTS {2, 3}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE  DEGRADED
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY THERMAL
            --#ACTION "Check the system for hardware failures and verify the environment is properly cooled."
    
            ::= 6040
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoGUIDCanonical'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH-MIB

    Related source files and packages:


    Source location: CPQHLTH-MIB::cpqHe3TemperatureFailed.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.131421+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHLTH-MIB

    Published definition
    cpqHe3TemperatureFailed TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqHeTemperatureChassis,
                         cpqHeTemperatureLocale }
            DESCRIPTION
                "The temperature status has been set to failed in the
                specified chassis and location.
    
                The system will be shutdown due to this condition."
    
            --#TYPE "Thermal Failure (6040)"
            --#SUMMARY "Temperature exceeded on chassis %d, location %d."
            --#ARGUMENTS {2, 3}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE  DEGRADED
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY THERMAL
            --#ACTION "Check the system for hardware failures and verify the environment is properly cooled."
    
            ::= 6040
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoGUIDCanonical'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}
    · Download CPQHLTH-MIB

    Related source files and packages:


    Source location: CPQHLTH-MIB::cpqHe3TemperatureFailed.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.153279+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.136032001 mngmtAgentTrap-3200100
1.3.6.1.4.1.232.0.136032002 mngmtAgentTrap-3200200
1.3.6.1.4.1.232.0.136033001 mngmtAgentTrap-3300100
1.3.6.1.4.1.232.0.136033002 mngmtAgentTrap-3300200
1.3.6.1.4.1.232.0.136033003 mngmtAgentTrap-3300300
1.3.6.1.4.1.232.0.136033004 mngmtAgentTrap-3300400
1.3.6.1.4.1.232.0.136035000 mngmtAgentTrap-3500000