Reference record for OID 1.3.6.1.4.1.232.0.8006

Parent
1.3.6.1.4.1.232.0 (0)
Node code
8006
Node name
cpqSsSidePanelRemoved
Numeric OID
1.3.6.1.4.1.232.0.8006
URN notation
urn:oid:1.3.6.1.4.1.232.0.8006
ASN.1 notation

{1 3 6 1 4 1 232 0 8006}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSsSidePanelRemoved(8006)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSsSidePanelRemoved(8006)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/8006
  • /ISO/Identified-Organization/6/1/4/1/232/0/8006
  • /ISO/3/6/1/4/1/232/0/8006
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqSsSidePanelRemoved
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqSsSidePanelRemoved
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqSsSidePanelRemoved
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqSsSidePanelRemoved
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqSsSidePanelRemoved
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqSsSidePanelRemoved
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqSsSidePanelRemoved
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqSsSidePanelRemoved
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqSsSidePanelRemoved
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqSsSidePanelRemoved
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqSsSidePanelRemoved
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqSsSidePanelRemoved
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqSsSidePanelRemoved
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqSsSidePanelRemoved
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqSsSidePanelRemoved
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqSsSidePanelRemoved
  • Additional combinations skipped.

Descriptions

cpqSsSidePanelRemoved — Circitor, MIBdepot

Storage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel.

cpqSsSidePanelRemoved — HPE networking MIB copies (LibreNMS/Observium Community)

Storage System side panel is removed. The side panel status has been set to removed. The storage system`s side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel.

Source records

cpqSsSidePanelRemoved

Status in source: unspecified.

Names: cpqSsSidePanelRemoved

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSsSidePanelRemoved",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "cpqSsBoxSidePanelStatus",
    "}",
    "DESCRIPTION",
    "\"Storage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel.\"",
    "::=",
    "8006"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "cpqSsBoxSidePanelStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Storage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSsSidePanelRemoved TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxSidePanelStatus }
            DESCRIPTION
               "Storage System side panel is removed.
    
                The side panel status has been set to removed.  The storage
                system's side panel is not in a properly installed state. This
                situation may result in improper cooling of the drives in the
                storage system due to air flow changes caused by the missing
                side panel."
    
                  --#TYPE "Storage System side panel is removed"
                  --#SUMMARY "Side panel is removed from unit."
                  --#ARGUMENTS {}
                  --#SEVERITY MAJOR
                  --#TIMEINDEX 99
                  --#STATE DEGRADED
    
            ::= 8006
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqstsys.mib.txt
    Source location: CPQSTSYS-MIB::cpqSsSidePanelRemoved.
    Source version and references

    Archived: 2026-10-19T00:22:07.892342+00:00.

  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSsSidePanelRemoved TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxSidePanelStatus }
            DESCRIPTION
               "Storage System side panel is removed.
    
                The side panel status has been set to removed.  The storage
                system's side panel is not in a properly installed state. This
                situation may result in improper cooling of the drives in the
                storage system due to air flow changes caused by the missing
                side panel."
    
                  --#TYPE "Storage System side panel is removed (8006)"
                  --#SUMMARY "Side panel is removed from unit."
                  --#ARGUMENTS {}
                  --#SEVERITY MAJOR
                  --#TIMEINDEX 99
                  --#STATE DEGRADED
    
            ::= 8006
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS.MIB.txt
    Source location: CPQSTSYS-MIB::cpqSsSidePanelRemoved.
    Source version and references

    Archived: 2026-10-19T00:22:08.794543+00:00.

  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSsSidePanelRemoved TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxSidePanelStatus }
            DESCRIPTION
               "Storage System side panel is removed.
    
                The side panel status has been set to removed.  The storage
                system's side panel is not in a properly installed state. This
                situation may result in improper cooling of the drives in the
                storage system due to air flow changes caused by the missing
                side panel."
    
                  --#TYPE "Storage System side panel is removed"
                  --#SUMMARY "Side panel is removed from unit."
                  --#ARGUMENTS {}
                  --#SEVERITY MAJOR
                  --#TIMEINDEX 99
                  --#STATE DEGRADED
    
            ::= 8006
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS1.MIB.txt
    Source location: CPQSTSYS-MIB::cpqSsSidePanelRemoved.
    Source version and references

    Archived: 2026-10-19T00:22:08.795134+00:00.

  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSsSidePanelRemoved TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxSidePanelStatus }
            DESCRIPTION
               "Storage System side panel is removed.
    
                The side panel status has been set to removed.  The storage
                system's side panel is not in a properly installed state. This
                situation may result in improper cooling of the drives in the
                storage system due to air flow changes caused by the missing
                side panel."
    
                  --#TYPE "Storage System side panel is removed"
                  --#SUMMARY "Side panel is removed from unit."
                  --#ARGUMENTS {}
                  --#SEVERITY MAJOR
                  --#TIMEINDEX 99
                  --#STATE DEGRADED
    
            ::= 8006
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS2.MIB.txt
    Source location: CPQSTSYS-MIB::cpqSsSidePanelRemoved.
    Source version and references

    Archived: 2026-10-19T00:22:08.795732+00:00.

  • Preserved circitor archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSsSidePanelRemoved TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxSidePanelStatus }
            DESCRIPTION
               "Storage System side panel is removed.
    
                The side panel status has been set to removed.  The storage
                system's side panel is not in a properly installed state. This
                situation may result in improper cooling of the drives in the
                storage system due to air flow changes caused by the missing
                side panel."
    
                  --#TYPE "Storage System side panel is removed (8006)"
                  --#SUMMARY "Side panel is removed from unit."
                  --#ARGUMENTS {}
                  --#SEVERITY MAJOR
                  --#TIMEINDEX 99
                  --#STATE DEGRADED
    
            ::= 8006
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS-MIB.mib
    Source location: CPQSTSYS-MIB::cpqSsSidePanelRemoved.
    Source version and references

    Archived: 2026-10-19T00:22:16.804433+00:00.

cpqSsSidePanelRemoved

Status in source: unspecified.

Names: cpqSsSidePanelRemoved

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSsSidePanelRemoved",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "cpqSsBoxSidePanelStatus",
    "}",
    "DESCRIPTION",
    "\"Storage System side panel is removed. The side panel status has been set to removed. The storage system`s side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel.\"",
    "::=",
    "8006"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "cpqSsBoxSidePanelStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Storage System side panel is removed. The side panel status has been set to removed. The storage system`s side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSTSYS-MIB

    Published definition
    cpqSsSidePanelRemoved TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxSidePanelStatus }
            DESCRIPTION
               "Storage System side panel is removed.
    
                The side panel status has been set to removed.  The storage
                system`s side panel is not in a properly installed state. This
                situation may result in improper cooling of the drives in the
                storage system due to air flow changes caused by the missing
                side panel."
    
                  --#TYPE "Storage System side panel is removed (8006)"
                  --#SUMMARY "Side panel is removed from unit."
                  --#ARGUMENTS {}
                  --#SEVERITY MAJOR
                  --#TIMEINDEX 99
                  --#STATE DEGRADED
    
            ::= 8006
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS-MIB

    Related source files and packages:


    Source location: CPQSTSYS-MIB::cpqSsSidePanelRemoved.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.413271+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.18005 cpqNic2ConnectivityRestored00
1.3.6.1.4.1.232.0.18006 cpqNic2ConnectivityLost00
1.3.6.1.4.1.232.0.18007 cpqNic2RedundancyIncreased00
1.3.6.1.4.1.232.0.18008 cpqNic2RedundancyReduced00
1.3.6.1.4.1.232.0.18009 cpqNicVirusLikeActivityDetected00
1.3.6.1.4.1.232.0.18010 cpqNicVirusLikeActivityStopped00
1.3.6.1.4.1.232.0.18011 cpqNic3ConnectivityRestored00
1.3.6.1.4.1.232.0.18012 cpqNic3ConnectivityLost00
1.3.6.1.4.1.232.0.18013 cpqNic3RedundancyIncreased00
1.3.6.1.4.1.232.0.18014 cpqNic3RedundancyReduced00
1.3.6.1.4.1.232.0.18015 cpqNicAllLinksDown00
1.3.6.1.4.1.232.0.18016 cpqNicAllLinksDownRepaired00
1.3.6.1.4.1.232.0.18017 cpqNicFlexLomTrainingFailed00
1.3.6.1.4.1.232.0.19001 cpqOsCpuTimeDegraded00
1.3.6.1.4.1.232.0.19002 cpqOsCpuTimeFailed00
1.3.6.1.4.1.232.0.19003 cpqOsCacheCopyReadHitsDegraded00
1.3.6.1.4.1.232.0.19004 cpqOsCacheCopyReadHitsFailed00
1.3.6.1.4.1.232.0.19005 cpqOsPageFileUsageDegraded00
1.3.6.1.4.1.232.0.19006 cpqOsPageFileUsageFailed00
1.3.6.1.4.1.232.0.19007 cpqOsLogicalDiskBusyTimeDegraded00
1.3.6.1.4.1.232.0.19008 cpqOsLogicalDiskBusyTimeFailed00
1.3.6.1.4.1.232.0.22001 cpqRackNameChanged00
1.3.6.1.4.1.232.0.22002 cpqRackEnclosureNameChanged00
1.3.6.1.4.1.232.0.22003 cpqRackEnclosureRemoved00
1.3.6.1.4.1.232.0.22004 cpqRackEnclosureInserted00
1.3.6.1.4.1.232.0.22005 cpqRackEnclosureTempFailed00
1.3.6.1.4.1.232.0.22006 cpqRackEnclosureTempDegraded00
1.3.6.1.4.1.232.0.22007 cpqRackEnclosureTempOk00
1.3.6.1.4.1.232.0.22008 cpqRackEnclosureFanFailed00
1.3.6.1.4.1.232.0.22009 cpqRackEnclosureFanDegraded00
1.3.6.1.4.1.232.0.22010 cpqRackEnclosureFanOk00
1.3.6.1.4.1.232.0.22011 cpqRackEnclosureFanRemoved00
1.3.6.1.4.1.232.0.22012 cpqRackEnclosureFanInserted00
1.3.6.1.4.1.232.0.22013 cpqRackPowerSupplyFailed00
1.3.6.1.4.1.232.0.22014 cpqRackPowerSupplyDegraded00
1.3.6.1.4.1.232.0.22015 cpqRackPowerSupplyOk00
1.3.6.1.4.1.232.0.22016 cpqRackPowerSupplyRemoved00
1.3.6.1.4.1.232.0.22017 cpqRackPowerSupplyInserted00
1.3.6.1.4.1.232.0.22018 cpqRackPowerSubsystemNotRedundant00
1.3.6.1.4.1.232.0.22019 cpqRackPowerSubsystemLineVoltageProblem00
1.3.6.1.4.1.232.0.22020 cpqRackPowerSubsystemOverloadCondition00
1.3.6.1.4.1.232.0.22021 cpqRackPowerShedAutoShutdown00
1.3.6.1.4.1.232.0.22022 cpqRackServerPowerOnFailedNotRedundant00
1.3.6.1.4.1.232.0.22023 cpqRackServerPowerOnFailedNotEnoughPower00
1.3.6.1.4.1.232.0.22024 cpqRackServerPowerOnFailedEnclosureNotFound00
1.3.6.1.4.1.232.0.22025 cpqRackServerPowerOnFailedPowerChassisNotFound00
1.3.6.1.4.1.232.0.22026 cpqRackServerPowerOnManualOverride00
1.3.6.1.4.1.232.0.22027 cpqRackFuseOpen00
1.3.6.1.4.1.232.0.22028 cpqRackServerBladeRemoved00
1.3.6.1.4.1.232.0.22029 cpqRackServerBladeInserted00