OID reference

cpqScsiLogDrvStatusChange

1.3.6.1.4.1.232.5.0.2

Description

Logical Drive Status Change. The agent has detected a change in the Logical Drive Status of a SCSI logical drive. The current logical drive status is indicated by the cpqScsiLogDrvStatus variable.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.232.5.0 (0)
Node code
2
Node name
cpqScsiLogDrvStatusChange
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.232.5.0.2
URN notation
urn:oid:1.3.6.1.4.1.232.5.0.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 232 5 0 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) cpqScsi(5) 0 cpqScsiLogDrvStatusChange(2)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/5/0/2
  • /ISO/Identified-Organization/6/1/4/1/232/5/0/2
  • /ISO/3/6/1/4/1/232/5/0/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/hp/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/org/dod/internet/private/enterprise/compaq/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/org/dod/internet/private/enterprise/hp/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/org/dod/internet/private/enterprise/Compaq/cpqScsi/0/cpqScsiLogDrvStatusChange
  • /iso/org/dod/internet/private/enterprises/compaq/cpqScsi/0/cpqScsiLogDrvStatusChange
  • Additional combinations skipped.

Available source records contain 5 distinct definitions; some records may not include a definition.

Show 5 published definitions

cpqScsiLogDrvStatusChange · unspecified

cpqScsiLogDrvStatusChange TRAP-TYPE
        ENTERPRISE cpqScsi
        VARIABLES  { cpqScsiLogDrvStatus }
        DESCRIPTION
           "Logical Drive Status Change.

            The agent has detected a change in the Logical Drive
            Status of a SCSI logical drive.  The current logical
            drive status is indicated by the cpqScsiLogDrvStatus variable."

              --#TYPE "SCSI Logical Drive Status Change (2)"
              --#SUMMARY "Status is now %d."
              --#ARGUMENTS {0}
              --#SEVERITY CRITICAL
              --#TIMEINDEX 99

        ::= 2

cpqScsiLogDrvStatusChange · unspecified

cpqScsiLogDrvStatusChange TRAP-TYPE
        ENTERPRISE cpqScsi
        VARIABLES  { cpqScsiLogDrvStatus }
        DESCRIPTION
           "Logical Drive Status Change.

            The Insight Agent has detected a change in the Logical Drive
            Status of a SCSI logical drive.  The current logical
            drive status is indicated by the cpqScsiLogDrvStatus variable."

              --#TYPE "SCSI Logical Drive Status Change"
              --#SUMMARY "Status is now %d."
              --#ARGUMENTS {0}
              --#SEVERITY CRITICAL
              --#TIMEINDEX 99

        ::= 2

cpqScsiLogDrvStatusChange · unspecified

cpqScsiLogDrvStatusChange TRAP-TYPE
        ENTERPRISE cpqScsi
        VARIABLES  { cpqScsiLogDrvStatus }
        DESCRIPTION
           "Logical Drive Status Change.

            The Insight Agent has detected a change in the Logical Drive
            Status of a Compaq SCSI logical drive.  The current logical
            drive status is indicated by the cpqScsiLogDrvStatus variable."

              --#TYPE "SCSI Logical Drive Status Change"
              --#SUMMARY "Status is now %d."
              --#ARGUMENTS {0}
              --#SEVERITY CRITICAL
              --#TIMEINDEX 99

        ::= 2

cpqScsiLogDrvStatusChange · unspecified

cpqScsiLogDrvStatusChange TRAP-TYPE
        ENTERPRISE cpqScsi
        VARIABLES  { cpqScsiLogDrvStatus }
        DESCRIPTION
           "Logical Drive Status Change.

            The Insight Agent has detected a change in the Logical Drive
            Status of a Compaq SCSI logical drive.  The current logical
            drive status is indicated by the cpqScsiLogDrvStatus variable."

              --#TYPE "SCSI Logical Drive Status Change"
              --#SUMMARY "Status is now %d."
              --#ARGUMENTS {0}
              --#SEVERITY CRITICAL
              --#TIMEINDEX 99

        ::= 2

cpqScsiLogDrvStatusChange · unspecified

cpqScsiLogDrvStatusChange TRAP-TYPE 
        ENTERPRISE cpqScsi 
        VARIABLES  { cpqScsiLogDrvStatus } 
        DESCRIPTION 
           "Logical Drive Status Change. 
 
            The Insight Agent has detected a change in the Logical Drive 
            Status of a Compaq SCSI logical drive.  The current logical 
            drive status is indicated by the cpqScsiLogDrvStatus variable." 
 
              --#TYPE "SCSI Logical Drive Status Change" 
              --#SUMMARY "Status is now %d." 
              --#ARGUMENTS {0} 
              --#SEVERITY CRITICAL 
              --#TIMEINDEX 99 
 
        ::= 2

Meaning

Descriptions

3 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Logical Drive Status Change. The agent has detected a change in the Logical Drive Status of a SCSI logical drive. The current logical drive status is indicated by the cpqScsiLogDrvStatus variable.

Sources for this description

HPE networking MIB copies (LibreNMS/Observium Community)MIBdepot

See 1 matching source record

Description 2

Logical Drive Status Change. The Insight Agent has detected a change in the Logical Drive Status of a SCSI logical drive. The current logical drive status is indicated by the cpqScsiLogDrvStatus variable.

Sources for this description

Circitor

See 1 matching source record

Description 3

Logical Drive Status Change. The Insight Agent has detected a change in the Logical Drive Status of a Compaq SCSI logical drive. The current logical drive status is indicated by the cpqScsiLogDrvStatus variable.

Sources for this description

MIBdepot

See 1 matching source record

Evidence

Source records

3 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot1 record · 2 sources

Description 1

cpqScsiLogDrvStatusChange · unspecifiedHPE networking MIB copies (LibreNMS/Observium Community), MIBdepot2 sources

Status in source: unspecified.

Names: cpqScsiLogDrvStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqScsiLogDrvStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "cpqScsi",
    "VARIABLES",
    "{",
    "cpqScsiLogDrvStatus",
    "}",
    "DESCRIPTION",
    "\"Logical Drive Status Change. The agent has detected a change in the Logical Drive Status of a SCSI logical drive. The current logical drive status is indicated by the cpqScsiLogDrvStatus variable.\"",
    "::=",
    "2"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "cpqScsi"
      ]
    ],
    [
      "VarTypes",
      [
        "cpqScsiLogDrvStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Logical Drive Status Change. The agent has detected a change in the Logical Drive Status of a SCSI logical drive. The current logical drive status is indicated by the cpqScsiLogDrvStatus variable."
    ],
    null
  ]
}
Records for description 2Circitor1 record · 1 source

Description 2

cpqScsiLogDrvStatusChange · unspecifiedCircitor1 source

Status in source: unspecified.

Names: cpqScsiLogDrvStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqScsiLogDrvStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "cpqScsi",
    "VARIABLES",
    "{",
    "cpqScsiLogDrvStatus",
    "}",
    "DESCRIPTION",
    "\"Logical Drive Status Change. The Insight Agent has detected a change in the Logical Drive Status of a SCSI logical drive. The current logical drive status is indicated by the cpqScsiLogDrvStatus variable.\"",
    "::=",
    "2"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "cpqScsi"
      ]
    ],
    [
      "VarTypes",
      [
        "cpqScsiLogDrvStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Logical Drive Status Change. The Insight Agent has detected a change in the Logical Drive Status of a SCSI logical drive. The current logical drive status is indicated by the cpqScsiLogDrvStatus variable."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQSCSI-MIB

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSCSI-MIB.mib
Records for description 3MIBdepot1 record · 3 sources

Description 3

cpqScsiLogDrvStatusChange · unspecifiedMIBdepot3 sources

Status in source: unspecified.

Names: cpqScsiLogDrvStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqScsiLogDrvStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "cpqScsi",
    "VARIABLES",
    "{",
    "cpqScsiLogDrvStatus",
    "}",
    "DESCRIPTION",
    "\"Logical Drive Status Change. The Insight Agent has detected a change in the Logical Drive Status of a Compaq SCSI logical drive. The current logical drive status is indicated by the cpqScsiLogDrvStatus variable.\"",
    "::=",
    "2"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "cpqScsi"
      ]
    ],
    [
      "VarTypes",
      [
        "cpqScsiLogDrvStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Logical Drive Status Change. The Insight Agent has detected a change in the Logical Drive Status of a Compaq SCSI logical drive. The current logical drive status is indicated by the cpqScsiLogDrvStatus variable."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSCSI-MIB

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqscsi.mib.txt
  • Preserved mibdepot archive

    Module: CPQSCSI-MIB

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSCSI1.MIB.txt

Siblings (2)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.5.0.1 cpqScsiCntlrStatusChange00
1.3.6.1.4.1.232.5.0.3 cpqScsiPhyDrvStatusChange00