Reference record for OID 1.3.6.1.4.1.232.6.2.20.2.1.7

Parent
1.3.6.1.4.1.232.6.2.20.2.1 (cpqHePowerFailureTableEntry)
Node code
7
Node name
cpqHePowerFailureRepairSteps
Numeric OID
1.3.6.1.4.1.232.6.2.20.2.1.7
URN notation
urn:oid:1.3.6.1.4.1.232.6.2.20.2.1.7
ASN.1 notation

{1 3 6 1 4 1 232 6 2 20 2 1 7}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) cpqHealth(6) cpqHeComponent(2) cpqHePowerFailure(20) cpqHePowerFailureTable(2) cpqHePowerFailureTableEntry(1) cpqHePowerFailureRepairSteps(7)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/6/2/20/2/1/7
  • /ISO/Identified-Organization/6/1/4/1/232/6/2/20/2/1/7
  • /ISO/3/6/1/4/1/232/6/2/20/2/1/7
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/identified-organization/dod/internet/private/enterprises/hp/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/org/dod/internet/private/enterprise/compaq/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/org/dod/internet/private/enterprise/hp/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/org/dod/internet/private/enterprise/Compaq/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • /iso/org/dod/internet/private/enterprises/compaq/cpqHealth/cpqHeComponent/cpqHePowerFailure/cpqHePowerFailureTable/cpqHePowerFailureTableEntry/cpqHePowerFailureRepairSteps
  • Additional combinations skipped.

Descriptions

cpqHePowerFailureRepairSteps — HPE networking MIB copies (LibreNMS/Observium Community)

Recommended troubleshooting steps for a particular device error. The value will be one of the following: noError(1) No errors were detected at this time. systemBoardRpMsg1(2) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Restore the server to its base configuration. Attempt to boot the server. (3)If error persists, capture the AHS logs and contact your support representative for assistance. processorRpMsg1(3) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Processor that has an issue. Attempt to boot the server. (3) Swap the faulty Processor with a known good Processor. Attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. memoryRpMsg1(4) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall all DIMM's in the memory channel group connected to the CPU that logged the error. Attempt to boot the server. (3) Swap the first DIMM in the memory channel group with a known good DIMM. Attempt to boot the server. If the server doesn't boot, repeat step 3 by swapping each DIMM in the memory channel group, one DIMM at a time until the bad DIMM is found. (4) If error persists, capture the AHS logs and contact your support representative for assistance. memoryBoardRpMsg1(5) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove the cartridge of the Memory Board that logged the error. Open the cartridge and reseat the DIMM's. Attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. riserCardAssemblyRpMsg1(6) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Riser Board that has an issue. Attempt to boot the server. (3) Remove the Riser Board then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. flexibleLomRpMsg1(7) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible LOM that has an issue. Attempt to boot the server. (3) Remove the Flexible LOM then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. flexibleSmartArrayRpMsg1(8) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible Smart Array Controller that has an issue. Attempt to boot the server. (3) Remove the Flexible Smart Array Controller then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. optIOPCIeSlotsRpMsg1(9) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Option Card that has an issue. Attempt to boot the server. (3) Remove all Option Cards from the system. Attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. powerBackplaneRpMsg1(10) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove GPU power connects one at a time in order to isolate the bad GPU card, each time attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. sasBackplaneRpMsg1(11) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall Storage Blackplane that logged the error (including cables). Attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. powerSupplyRpMsg1(12) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Swap the first Power Supply with a known good Power supply. Attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. mezzCardRpMsg1(13) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Mezzanine Card that has an issue. Attempt to boot the server. (3) Remove the Mezzanine Card then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. enclosureRpMsg1(14) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Restore the enclosure to its base configuration. Attempt to boot the server. (2) If error persists, capture the AHS logs and contact your support representative for assistance.

Source records

cpqHePowerFailureRepairSteps

Status in source: mandatory.

Names: cpqHePowerFailureRepairSteps

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "cpqHePowerFailureRepairSteps",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "noError",
    "(",
    "1",
    ")",
    ",",
    "systemBoardRpMsg1",
    "(",
    "2",
    ")",
    ",",
    "processorRpMsg1",
    "(",
    "3",
    ")",
    ",",
    "memoryRpMsg1",
    "(",
    "4",
    ")",
    ",",
    "memoryBoardRpMsg1",
    "(",
    "5",
    ")",
    ",",
    "riserCardAssemblyRpMsg1",
    "(",
    "6",
    ")",
    ",",
    "flexibleLomRpMsg1",
    "(",
    "7",
    ")",
    ",",
    "flexibleSmartArrayRpMsg1",
    "(",
    "8",
    ")",
    ",",
    "optIOPCIeSlotsRpMsg1",
    "(",
    "9",
    ")",
    ",",
    "powerBackplaneRpMsg1",
    "(",
    "10",
    ")",
    ",",
    "sasBackplaneRpMsg1",
    "(",
    "11",
    ")",
    ",",
    "powerSupplyRpMsg1",
    "(",
    "12",
    ")",
    ",",
    "mezzCardRpMsg1",
    "(",
    "13",
    ")",
    ",",
    "enclosureRpMsg1",
    "(",
    "14",
    ")",
    "}",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Recommended troubleshooting steps for a particular device error. The value will be one of the following: noError(1) No errors were detected at this time. systemBoardRpMsg1(2) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Restore the server to its base configuration. Attempt to boot the server. (3)If error persists, capture the AHS logs and contact your support representative for assistance. processorRpMsg1(3) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Processor that has an issue. Attempt to boot the server. (3) Swap the faulty Processor with a known good Processor. Attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. memoryRpMsg1(4) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall all DIMM's in the memory channel group connected to the CPU that logged the error. Attempt to boot the server. (3) Swap the first DIMM in the memory channel group with a known good DIMM. Attempt to boot the server. If the server doesn't boot, repeat step 3 by swapping each DIMM in the memory channel group, one DIMM at a time until the bad DIMM is found. (4) If error persists, capture the AHS logs and contact your support representative for assistance. memoryBoardRpMsg1(5) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove the cartridge of the Memory Board that logged the error. Open the cartridge and reseat the DIMM's. Attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. riserCardAssemblyRpMsg1(6) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Riser Board that has an issue. Attempt to boot the server. (3) Remove the Riser Board then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. flexibleLomRpMsg1(7) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible LOM that has an issue. Attempt to boot the server. (3) Remove the Flexible LOM then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. flexibleSmartArrayRpMsg1(8) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible Smart Array Controller that has an issue. Attempt to boot the server. (3) Remove the Flexible Smart Array Controller then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. optIOPCIeSlotsRpMsg1(9) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Option Card that has an issue. Attempt to boot the server. (3) Remove all Option Cards from the system. Attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. powerBackplaneRpMsg1(10) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove GPU power connects one at a time in order to isolate the bad GPU card, each time attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. sasBackplaneRpMsg1(11) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall Storage Blackplane that logged the error (including cables). Attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. powerSupplyRpMsg1(12) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Swap the first Power Supply with a known good Power supply. Attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. mezzCardRpMsg1(13) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Mezzanine Card that has an issue. Attempt to boot the server. (3) Remove the Mezzanine Card then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. enclosureRpMsg1(14) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Restore the enclosure to its base configuration. Attempt to boot the server. (2) If error persists, capture the AHS logs and contact your support representative for assistance.\"",
    "::=",
    "{",
    "cpqHePowerFailureTableEntry",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "noError",
            1
          ],
          [
            "systemBoardRpMsg1",
            2
          ],
          [
            "processorRpMsg1",
            3
          ],
          [
            "memoryRpMsg1",
            4
          ],
          [
            "memoryBoardRpMsg1",
            5
          ],
          [
            "riserCardAssemblyRpMsg1",
            6
          ],
          [
            "flexibleLomRpMsg1",
            7
          ],
          [
            "flexibleSmartArrayRpMsg1",
            8
          ],
          [
            "optIOPCIeSlotsRpMsg1",
            9
          ],
          [
            "powerBackplaneRpMsg1",
            10
          ],
          [
            "sasBackplaneRpMsg1",
            11
          ],
          [
            "powerSupplyRpMsg1",
            12
          ],
          [
            "mezzCardRpMsg1",
            13
          ],
          [
            "enclosureRpMsg1",
            14
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Recommended troubleshooting steps for a particular device error. The value will be one of the following: noError(1) No errors were detected at this time. systemBoardRpMsg1(2) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Restore the server to its base configuration. Attempt to boot the server. (3)If error persists, capture the AHS logs and contact your support representative for assistance. processorRpMsg1(3) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Processor that has an issue. Attempt to boot the server. (3) Swap the faulty Processor with a known good Processor. Attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. memoryRpMsg1(4) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall all DIMM's in the memory channel group connected to the CPU that logged the error. Attempt to boot the server. (3) Swap the first DIMM in the memory channel group with a known good DIMM. Attempt to boot the server. If the server doesn't boot, repeat step 3 by swapping each DIMM in the memory channel group, one DIMM at a time until the bad DIMM is found. (4) If error persists, capture the AHS logs and contact your support representative for assistance. memoryBoardRpMsg1(5) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove the cartridge of the Memory Board that logged the error. Open the cartridge and reseat the DIMM's. Attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. riserCardAssemblyRpMsg1(6) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Riser Board that has an issue. Attempt to boot the server. (3) Remove the Riser Board then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. flexibleLomRpMsg1(7) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible LOM that has an issue. Attempt to boot the server. (3) Remove the Flexible LOM then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. flexibleSmartArrayRpMsg1(8) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible Smart Array Controller that has an issue. Attempt to boot the server. (3) Remove the Flexible Smart Array Controller then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. optIOPCIeSlotsRpMsg1(9) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Option Card that has an issue. Attempt to boot the server. (3) Remove all Option Cards from the system. Attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. powerBackplaneRpMsg1(10) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove GPU power connects one at a time in order to isolate the bad GPU card, each time attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. sasBackplaneRpMsg1(11) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall Storage Blackplane that logged the error (including cables). Attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. powerSupplyRpMsg1(12) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Swap the first Power Supply with a known good Power supply. Attempt to boot the server. (3) If error persists, capture the AHS logs and contact your support representative for assistance. mezzCardRpMsg1(13) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Mezzanine Card that has an issue. Attempt to boot the server. (3) Remove the Mezzanine Card then attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support representative for assistance. enclosureRpMsg1(14) Try the following steps until the error no longer occurs: (1) Remove AC power, then restore AC power. (2) Restore the enclosure to its base configuration. Attempt to boot the server. (2) If error persists, capture the AHS logs and contact your support representative for assistance."
    ],
    null,
    null,
    null,
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQHLTH-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQHLTH-MIB

    Published definition
    cpqHePowerFailureRepairSteps OBJECT-TYPE
          SYNTAX  INTEGER {
             noError(1),
             systemBoardRpMsg1(2),
             processorRpMsg1(3),
             memoryRpMsg1(4),
             memoryBoardRpMsg1(5),
             riserCardAssemblyRpMsg1(6),
             flexibleLomRpMsg1(7),
             flexibleSmartArrayRpMsg1(8),
             optIOPCIeSlotsRpMsg1(9),
             powerBackplaneRpMsg1(10),
             sasBackplaneRpMsg1(11),
             powerSupplyRpMsg1(12),
             mezzCardRpMsg1(13),
             enclosureRpMsg1(14)
          }
          ACCESS  read-only
          STATUS  mandatory
          DESCRIPTION
             "Recommended troubleshooting steps for a particular device error.
             The value will be one of the following:
             
             noError(1)
               No errors were detected at this time.
    
             systemBoardRpMsg1(2)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Restore the server to its base 
    		   configuration. Attempt to boot the server. (3)If error persists, capture the AHS 
    		   logs and contact your support representative for assistance.
    
             processorRpMsg1(3)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Processor 
    		   that has an issue. Attempt to boot the server. (3) Swap the faulty Processor with a 
    		   known good Processor. Attempt to boot the server. (4) If error persists, capture the AHS 
    		   logs and contact your support representative for assistance.
    
    
             memoryRpMsg1(4)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall all DIMM's in 
    		   the memory channel group connected to the CPU that logged the error. Attempt to boot the 
    		   server. (3) Swap the first DIMM in the memory channel group with a known good DIMM.
    		   Attempt to boot the server.  If the server doesn't boot, repeat step 3 by swapping each
    		   DIMM in the memory channel group, one DIMM at a time until the bad DIMM is found.  
    		   (4) If error persists, capture the AHS logs and contact your support representative for 
    		   assistance.
    
    
             memoryBoardRpMsg1(5)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove the cartridge of the Memory
    		   Board that logged the error.  Open the cartridge and reseat the DIMM's. Attempt to boot 
    		   the server. (3) If error persists, capture the AHS logs and contact your support representative 
    		   for assistance.
    
    
             riserCardAssemblyRpMsg1(6)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Riser Board 
    		   that has an issue. Attempt to boot the server. (3) Remove the Riser Board then attempt 
    		   to boot the server. (4) If error persists, capture the AHS logs and contact your support 
    		   representative for assistance.
    
    
             flexibleLomRpMsg1(7)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible 
    		   LOM that has an issue. Attempt to boot the server. (3) Remove the Flexible LOM then  
    		   attempt to boot the server. (4) If error persists, capture the AHS logs and contact your 
    		   support representative for assistance.
    
    
             flexibleSmartArrayRpMsg1(8)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible 
    		   Smart Array Controller that has an issue. Attempt to boot the server. (3) Remove the 
    		   Flexible Smart Array Controller then attempt to boot the server. (4) If error persists, capture 
    		   the AHS logs and contact your support representative for assistance.
    
    
             optIOPCIeSlotsRpMsg1(9)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Option Card
    		   that has an issue. Attempt to boot the server. (3) Remove all Option Cards from the system.
    		   Attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support 
    		   representative for assistance.
    
    
             powerBackplaneRpMsg1(10)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove GPU power connects one at a time
    		   in order to isolate the bad GPU card, each time attempt to boot the server. (3) If error persists,
    		   capture the AHS logs and contact your support representative for assistance.
    
    
             sasBackplaneRpMsg1(11)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall Storage 
    		   Blackplane that logged the error (including cables). Attempt to boot the server. 
    		   (3) If error persists, capture the AHS logs and contact your support representative for assistance.
    
    
             powerSupplyRpMsg1(12)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Swap the first Power Supply with a 
    		   known good Power supply. Attempt to boot the server. (3) If error persists, capture the AHS 
    		   logs and contact your support representative for assistance.
    
    
             mezzCardRpMsg1(13)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Mezzanine 
    		   Card that has an issue. Attempt to boot the server. (3) Remove the Mezzanine Card then 
    		   attempt to boot the server. (4) If error persists, capture the AHS logs and contact your 
    		   support representative for assistance.
    		   
             enclosureRpMsg1(14)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Restore the enclosure to its base 
    		   configuration. Attempt to boot the server. (2) If error persists, capture the AHS logs 
    		   and contact your support representative for assistance."
    
    
          ::= { cpqHePowerFailureTableEntry 7 }
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoGUIDCanonical'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}

    Related source files and packages:


    Source location: CPQHLTH-MIB::cpqHePowerFailureRepairSteps.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.131421+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHLTH-MIB

    Published definition
    cpqHePowerFailureRepairSteps OBJECT-TYPE
          SYNTAX  INTEGER {
             noError(1),
             systemBoardRpMsg1(2),
             processorRpMsg1(3),
             memoryRpMsg1(4),
             memoryBoardRpMsg1(5),
             riserCardAssemblyRpMsg1(6),
             flexibleLomRpMsg1(7),
             flexibleSmartArrayRpMsg1(8),
             optIOPCIeSlotsRpMsg1(9),
             powerBackplaneRpMsg1(10),
             sasBackplaneRpMsg1(11),
             powerSupplyRpMsg1(12),
             mezzCardRpMsg1(13),
             enclosureRpMsg1(14)
          }
          ACCESS  read-only
          STATUS  mandatory
          DESCRIPTION
             "Recommended troubleshooting steps for a particular device error.
             The value will be one of the following:
             
             noError(1)
               No errors were detected at this time.
    
             systemBoardRpMsg1(2)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Restore the server to its base 
    		   configuration. Attempt to boot the server. (3)If error persists, capture the AHS 
    		   logs and contact your support representative for assistance.
    
             processorRpMsg1(3)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Processor 
    		   that has an issue. Attempt to boot the server. (3) Swap the faulty Processor with a 
    		   known good Processor. Attempt to boot the server. (4) If error persists, capture the AHS 
    		   logs and contact your support representative for assistance.
    
    
             memoryRpMsg1(4)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall all DIMM's in 
    		   the memory channel group connected to the CPU that logged the error. Attempt to boot the 
    		   server. (3) Swap the first DIMM in the memory channel group with a known good DIMM.
    		   Attempt to boot the server.  If the server doesn't boot, repeat step 3 by swapping each
    		   DIMM in the memory channel group, one DIMM at a time until the bad DIMM is found.  
    		   (4) If error persists, capture the AHS logs and contact your support representative for 
    		   assistance.
    
    
             memoryBoardRpMsg1(5)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove the cartridge of the Memory
    		   Board that logged the error.  Open the cartridge and reseat the DIMM's. Attempt to boot 
    		   the server. (3) If error persists, capture the AHS logs and contact your support representative 
    		   for assistance.
    
    
             riserCardAssemblyRpMsg1(6)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Riser Board 
    		   that has an issue. Attempt to boot the server. (3) Remove the Riser Board then attempt 
    		   to boot the server. (4) If error persists, capture the AHS logs and contact your support 
    		   representative for assistance.
    
    
             flexibleLomRpMsg1(7)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible 
    		   LOM that has an issue. Attempt to boot the server. (3) Remove the Flexible LOM then  
    		   attempt to boot the server. (4) If error persists, capture the AHS logs and contact your 
    		   support representative for assistance.
    
    
             flexibleSmartArrayRpMsg1(8)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible 
    		   Smart Array Controller that has an issue. Attempt to boot the server. (3) Remove the 
    		   Flexible Smart Array Controller then attempt to boot the server. (4) If error persists, capture 
    		   the AHS logs and contact your support representative for assistance.
    
    
             optIOPCIeSlotsRpMsg1(9)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Option Card
    		   that has an issue. Attempt to boot the server. (3) Remove all Option Cards from the system.
    		   Attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support 
    		   representative for assistance.
    
    
             powerBackplaneRpMsg1(10)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove GPU power connects one at a time
    		   in order to isolate the bad GPU card, each time attempt to boot the server. (3) If error persists,
    		   capture the AHS logs and contact your support representative for assistance.
    
    
             sasBackplaneRpMsg1(11)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall Storage 
    		   Blackplane that logged the error (including cables). Attempt to boot the server. 
    		   (3) If error persists, capture the AHS logs and contact your support representative for assistance.
    
    
             powerSupplyRpMsg1(12)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Swap the first Power Supply with a 
    		   known good Power supply. Attempt to boot the server. (3) If error persists, capture the AHS 
    		   logs and contact your support representative for assistance.
    
    
             mezzCardRpMsg1(13)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Mezzanine 
    		   Card that has an issue. Attempt to boot the server. (3) Remove the Mezzanine Card then 
    		   attempt to boot the server. (4) If error persists, capture the AHS logs and contact your 
    		   support representative for assistance.
    		   
             enclosureRpMsg1(14)
    		   Try the following steps until the error no longer occurs:
    		   (1) Remove AC power, then restore AC power. (2) Restore the enclosure to its base 
    		   configuration. Attempt to boot the server. (2) If error persists, capture the AHS logs 
    		   and contact your support representative for assistance."
    
    
          ::= { cpqHePowerFailureTableEntry 7 }
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoGUIDCanonical'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName'], 'CPQSINFO-MIB': ['cpqSiServerSystemId', 'cpqSiMemModuleSize']}

    Related source files and packages:


    Source location: CPQHLTH-MIB::cpqHePowerFailureRepairSteps.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.153279+00:00.

Siblings (7)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.6.2.20.2.1.1 cpqHePowerFailureIndex00
1.3.6.1.4.1.232.6.2.20.2.1.2 cpqHePowerFailureStatus00
1.3.6.1.4.1.232.6.2.20.2.1.3 cpqHePowerFailureDeviceID00
1.3.6.1.4.1.232.6.2.20.2.1.4 cpqHePowerFailureArea00
1.3.6.1.4.1.232.6.2.20.2.1.5 cpqHePowerFailureDeviceBitMap00
1.3.6.1.4.1.232.6.2.20.2.1.6 cpqHePowerFailureGroupString00
1.3.6.1.4.1.232.6.2.20.2.1.8 cpqHePowerFailureType00