Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cpqHeInterlockFailureType",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"noError",
"(",
"1",
")",
",",
"standby",
"(",
"2",
")",
",",
"runtime",
"(",
"3",
")",
",",
"powerOn",
"(",
"4",
")",
",",
"generic",
"(",
"5",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The type of critical Interlock failure that occurred. The value will be one of the following: noError(1) No error has occurred. standby(2) The server had a power fault that occurred while it was powered off. runtime(3) The server was shut down due to a power fault that occurred while it was powered on. powerOn(4) The server had a power fault that occurred while attempting to power on. generic(5) The server had a power fault but the reason is unknown. \"",
"::=",
"{",
"cpqHeInterlockFailureTableEntry",
"6",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"noError",
1
],
[
"standby",
2
],
[
"runtime",
3
],
[
"powerOn",
4
],
[
"generic",
5
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The type of critical Interlock failure that occurred. The value will be one of the following: noError(1) No error has occurred. standby(2) The server had a power fault that occurred while it was powered off. runtime(3) The server was shut down due to a power fault that occurred while it was powered on. powerOn(4) The server had a power fault that occurred while attempting to power on. generic(5) The server had a power fault but the reason is unknown."
],
null,
null,
null,
null
]
}