Configure PoE Chipset Reboot Time.
Sources for this description
LANCOM official release MIBsLANCOM MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2356.14.2.13.6.2
Configure PoE Chipset Reboot Time.
Identification
{1 3 6 1 4 1 2356 14 2 13 6 2}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
lcsPoeChipsetRebootTimeTable OBJECT-TYPE
SYNTAX SEQUENCE OF LCSPoeChipsetRebootTimeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Configure PoE Chipset Reboot Time."
::= { lcsPoeChipsetRebootSchedule 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Configure PoE Chipset Reboot Time.
LANCOM official release MIBsLANCOM MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: lcsPoeChipsetRebootTimeTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"lcsPoeChipsetRebootTimeTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"LCSPoeChipsetRebootTimeEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\" Configure PoE Chipset Reboot Time.\"",
"::=",
"{",
"lcsPoeChipsetRebootSchedule",
"2",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"LCSPoeChipsetRebootTimeEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Configure PoE Chipset Reboot Time."
],
null,
null,
null,
null
]
}Module: LCOS-SX-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3152X-4.30.0224-RU5.mib.
Same file in LC-GS-3126X-4.30.0224-RU5.mib.
Same file in LC-GS-3252P-4.30.0224-RU5.mib.
Same file in LC-GS-3652XUP-4.30.0224-RU5.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3628X-4.30.0302-RU6.mib.
Same file in LC-GS-2426-4.30.0302-RU6.mib.
Same file in LC-XS-3550YUP-4.30.0302-RU6.mib.
Same file in LC-GS-2412P-4.30.0302-RU6.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3510XP-4.30.0438-RU8.mib.
Same file in LC-GS-3628XP-4.30.0434-RU7.mib.
Same file in LC-GS-3126X-4.30.0438-RU8.mib.
Same file in LC-GS-3528X-4.30.0438-RU8.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3528X-4.30.0502-RU10.mib.
Same file in LC-XS-3510YUP-4.30.0502-RU10.mib.
Same file in LC-GS-3126X-4.30.0502-RU10.mib.
Same file in LC-GS-3126XP-4.30.0502-RU10.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Source data warning: The publisher uses a lowercase row/type name. Preserve this literal type reference and every numeric OID; do not silently change its spelling.
· Download LC-GS-3126X-4.00.0219-SU3.mibSame file in LC-GS-3152X-4.00.0212-RU2.mib.
Same file in LC-GS-3528X-4.00.0219-SU3.mib.
Same file in LC-GS-3152XSP-4.00.0212-RU2.mib.
Same file in LC-GS-3528XP-4.00.0212-RU2.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3528X-4.00.0261-RU4.mib.
Same file in LC-GS-3152X-4.00.0261-RU4.mib.
Same file in LC-GS-3510XP-4.00.0261-RU4.mib.
Same file in LC-GS-3152XP-4.00.0261-RU4.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3528X-4.00.0333-RU6.mib.
Same file in LC-GS-3152XSP-4.00.0333-RU6.mib.
Same file in LC-GS-3152XP-4.00.0333-RU6.mib.
Same file in LC-GS-3152XSP-4.00.0305-RU5.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3510XP-4.00.0349-RU7.mib.
Same file in LC-GS-3528X-4.00.0349-RU7.mib.
Same file in LC-GS-3152P-4.00.0349-RU7.mib.
Same file in LC-GS-3152XP-4.00.0349-RU7.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3126XP-4.00.0414-RU8.mib.
Same file in LC-GS-3152P-4.00.0414-RU8.mib.
Same file in LC-GS-3152X-4.00.0414-RU8.mib.
Same file in LC-GS-3152XP-4.00.0414-RU8.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3528XP-4.00.0501-RU9.mib.
Same file in LC-GS-3152XSP-4.00.0501-RU9.mib.
Same file in LC-GS-3152XP-4.00.0501-RU9.mib.
Same file in LC-GS-3152P-4.00.0501-RU9.mib.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2356.14.2.13.6.2.1 | lcsPoeChipsetRebootTimeEntry | 3 | 3 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2356.14.2.13.6.1 | lcsPoeChipsetRebootMode | 0 | 0 |