LMC Role rollout information string
Sources for this description
LANCOM official release MIBsLANCOM MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2356.14.2.1500.7
LMC Role rollout information string
Identification
{1 3 6 1 4 1 2356 14 2 1500 7}
Definitions may combine these properties differently.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
lcsLMCRolloutRole OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LMC Role rollout information string"
DEFVAL { "" }
::= { lcsLMC 7 }lcsLMCRolloutRole OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LMC Role rollout information string"
::= { lcsLMC 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
LMC Role rollout information string
LANCOM official release MIBsLANCOM MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: lcsLMCRolloutRole
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"lcsLMCRolloutRole",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"LMC Role rollout information string\"",
"DEFVAL",
"{",
[
"literal",
"2222"
],
"}",
"::=",
"{",
"lcsLMC",
"7",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"LMC Role rollout information string"
],
null,
null,
null,
[
"DEFVAL",
"\"\""
]
]
}Module: LCOS-SX-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3152X-4.30.0224-RU5.mib.
Same file in LC-GS-3126X-4.30.0224-RU5.mib.
Same file in LC-GS-3252P-4.30.0224-RU5.mib.
Same file in LC-GS-3652XUP-4.30.0224-RU5.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3628X-4.30.0302-RU6.mib.
Same file in LC-GS-2426-4.30.0302-RU6.mib.
Same file in LC-XS-3550YUP-4.30.0302-RU6.mib.
Same file in LC-GS-2412P-4.30.0302-RU6.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3510XP-4.30.0438-RU8.mib.
Same file in LC-GS-3628XP-4.30.0434-RU7.mib.
Same file in LC-GS-3126X-4.30.0438-RU8.mib.
Same file in LC-GS-3528X-4.30.0438-RU8.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3528X-4.30.0502-RU10.mib.
Same file in LC-XS-3510YUP-4.30.0502-RU10.mib.
Same file in LC-GS-3126X-4.30.0502-RU10.mib.
Same file in LC-GS-3126XP-4.30.0502-RU10.mib.
Status in source: current.
Names: lcsLMCRolloutRole
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"lcsLMCRolloutRole",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"LMC Role rollout information string\"",
"::=",
"{",
"lcsLMC",
"7",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"LMC Role rollout information string"
],
null,
null,
null,
null
]
}Module: LCOS-SX-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3126XP-4.00.0414-RU8.mib.
Same file in LC-GS-3152P-4.00.0414-RU8.mib.
Same file in LC-GS-3152X-4.00.0414-RU8.mib.
Same file in LC-GS-3152XP-4.00.0414-RU8.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3528XP-4.00.0501-RU9.mib.
Same file in LC-GS-3152XSP-4.00.0501-RU9.mib.
Same file in LC-GS-3152XP-4.00.0501-RU9.mib.
Same file in LC-GS-3152P-4.00.0501-RU9.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3126XP-4.00.0713-RU11.mib.
Same file in LC-GS-3152XP-4.00.0713-RU11.mib.
Same file in LC-GS-3152XSP-4.00.0713-RU11.mib.
Same file in LC-GS-3126X-4.00.0715-RU12.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3528X-4.00.0716-SU13.mib.
Same file in LC-GS-3510XP-4.00.0716-SU13.mib.
Same file in LC-GS-3152XSP-4.00.0716-SU13.mib.
Same file in LC-GS-3152X-4.00.0716-SU13.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3652XUP-4.30.0071-Rel.mib.
Same file in LC-IGS-3510XUP-4.30.0071-Rel.mib.
Same file in LC-GS-3126XP-4.30.0072-RU1.mib.
Same file in LC-GS-3652X-4.30.0071-Rel.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3652XP-4.30.0147-RU4.mib.
Same file in LC-XS-3510YUP-4.30.0147-RU4.mib.
Same file in LC-XS-3550YUP-4.30.0147-RU4.mib.
Same file in LC-GS-3628X-4.30.0147-RU4.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3152XSP-4.00.0614-RU10.mib.
Same file in LC-GS-3528X-4.00.0614-RU10.mib.
Same file in LC-GS-3528XP-4.00.0614-RU10.mib.
Same file in LC-GS-3152XP-4.00.0614-RU10.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3652XP-4.20.0074-Rel.mib.
Same file in LC-GS-3652X-4.20.0074-Rel.mib.
Same file in LC-GS-3628XUP-4.20.0074-Rel.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3628X-4.20.0126-RU1.mib.
Same file in LC-GS-3652X-4.20.0126-RU1.mib.
Same file in LC-GS-3652XUP-4.20.0126-RU1.mib.
Same file in LC-GS-3628XUP-4.20.0126-RU1.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3628XP-4.20.0242-SU3.mib.
Same file in LC-GS-3628X-4.20.0242-SU3.mib.
Same file in LC-GS-3652XP-4.20.0242-SU3.mib.
Same file in LC-GS-3652XUP-4.20.0242-SU3.mib.
Registration