MSTI2 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority.
Sources for this description
LANCOM official release MIBsLANCOM MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2356.14.2.18.4.3
MSTI2 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority.
Identification
{1 3 6 1 4 1 2356 14 2 18 4 3}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.2356.14.2.18.4.3.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
lcsMSTI2Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MSTI2 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority."
::= { lcsMSTIPriorities 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
MSTI2 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority.
LANCOM official release MIBsLANCOM MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: lcsMSTI2Priority
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"lcsMSTI2Priority",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"MSTI2 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority.\"",
"::=",
"{",
"lcsMSTIPriorities",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"MSTI2 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority."
],
null,
null,
null,
null
]
}Module: LCOS-SX-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3152X-4.30.0224-RU5.mib.
Same file in LC-GS-3126X-4.30.0224-RU5.mib.
Same file in LC-GS-3252P-4.30.0224-RU5.mib.
Same file in LC-GS-3652XUP-4.30.0224-RU5.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3628X-4.30.0302-RU6.mib.
Same file in LC-GS-2426-4.30.0302-RU6.mib.
Same file in LC-XS-3550YUP-4.30.0302-RU6.mib.
Same file in LC-GS-2412P-4.30.0302-RU6.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3510XP-4.30.0438-RU8.mib.
Same file in LC-GS-3628XP-4.30.0434-RU7.mib.
Same file in LC-GS-3126X-4.30.0438-RU8.mib.
Same file in LC-GS-3528X-4.30.0438-RU8.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3528X-4.30.0502-RU10.mib.
Same file in LC-XS-3510YUP-4.30.0502-RU10.mib.
Same file in LC-GS-3126X-4.30.0502-RU10.mib.
Same file in LC-GS-3126XP-4.30.0502-RU10.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Source data warning: The publisher uses a lowercase row/type name. Preserve this literal type reference and every numeric OID; do not silently change its spelling.
· Download LC-GS-3126X-4.00.0219-SU3.mibSame file in LC-GS-3152X-4.00.0212-RU2.mib.
Same file in LC-GS-3528X-4.00.0219-SU3.mib.
Same file in LC-GS-3152XSP-4.00.0212-RU2.mib.
Same file in LC-GS-3528XP-4.00.0212-RU2.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3528X-4.00.0261-RU4.mib.
Same file in LC-GS-3152X-4.00.0261-RU4.mib.
Same file in LC-GS-3510XP-4.00.0261-RU4.mib.
Same file in LC-GS-3152XP-4.00.0261-RU4.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3528X-4.00.0333-RU6.mib.
Same file in LC-GS-3152XSP-4.00.0333-RU6.mib.
Same file in LC-GS-3152XP-4.00.0333-RU6.mib.
Same file in LC-GS-3152XSP-4.00.0305-RU5.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3510XP-4.00.0349-RU7.mib.
Same file in LC-GS-3528X-4.00.0349-RU7.mib.
Same file in LC-GS-3152P-4.00.0349-RU7.mib.
Same file in LC-GS-3152XP-4.00.0349-RU7.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3126XP-4.00.0414-RU8.mib.
Same file in LC-GS-3152P-4.00.0414-RU8.mib.
Same file in LC-GS-3152X-4.00.0414-RU8.mib.
Same file in LC-GS-3152XP-4.00.0414-RU8.mib.
Module: LCOS-SX-MIB
{'IF-MIB': ['ifIndex'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['dot1qTpFdbAddress', 'dot1qFdbId', 'dot1qTpFdbPort'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Same file in LC-GS-3528XP-4.00.0501-RU9.mib.
Same file in LC-GS-3152XSP-4.00.0501-RU9.mib.
Same file in LC-GS-3152XP-4.00.0501-RU9.mib.
Same file in LC-GS-3152P-4.00.0501-RU9.mib.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2356.14.2.18.4.1 | lcsCSTIPriority | 0 | 0 | |
| 1.3.6.1.4.1.2356.14.2.18.4.2 | lcsMSTI1Priority | 0 | 0 | |
| 1.3.6.1.4.1.2356.14.2.18.4.4 | lcsMSTI3Priority | 0 | 0 | |
| 1.3.6.1.4.1.2356.14.2.18.4.5 | lcsMSTI4Priority | 0 | 0 | |
| 1.3.6.1.4.1.2356.14.2.18.4.6 | lcsMSTI5Priority | 0 | 0 | |
| 1.3.6.1.4.1.2356.14.2.18.4.7 | lcsMSTI6Priority | 0 | 0 | |
| 1.3.6.1.4.1.2356.14.2.18.4.8 | lcsMSTI7Priority | 0 | 0 |