gs2326plusNASPortConfigRADIUSAssignedVLANEnabled

1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.4

Description

When RADIUS-Assigned VLAN is both globally enabled and enabled (checked) for a given port, the switch reacts to VLAN ID information carried in the RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant is successfully authenticated. If present and valid, the port's Port VLAN ID will be changed …

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1 (gs2326plusNASPortConfigEntry)
Node code
4
Node name
gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.4
URN notation
urn:oid:1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 2356 800 3 2329 3 11 1 13 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lancom-systems(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) elsa(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lancomSystems(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lancom-systems(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) elsa(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lancomSystems(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) lancom-systems(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) elsa(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) lancomSystems(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) lancom-systems(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) elsa(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) lancomSystems(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lancom-systems(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) elsa(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lancomSystems(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) lancom-systems(2356) switchingSystems(800) gigabitEthernetSwitches(3) lancomGS2326plus(2329) gs2326plusSecurity(3) gs2326plusNAS(11) gs2326plusNASConfiguration(1) gs2326plusNASPortConfigTable(13) gs2326plusNASPortConfigEntry(1) gs2326plusNASPortConfigRADIUSAssignedVLANEnabled(4)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/2356/800/3/2329/3/11/1/13/1/4
  • /ISO/Identified-Organization/6/1/4/1/2356/800/3/2329/3/11/1/13/1/4
  • /ISO/3/6/1/4/1/2356/800/3/2329/3/11/1/13/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/ELSA/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/enterprise/lancom-systems/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/enterprise/elsa/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/enterprise/lancomSystems/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/enterprises/ELSA/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/enterprises/lancom-systems/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/enterprises/elsa/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/enterprises/lancomSystems/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/ELSA/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/lancom-systems/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/elsa/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/lancomSystems/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/vendor-objects/ELSA/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/vendor-objects/lancom-systems/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/vendor-objects/elsa/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • /iso/identified-organization/dod/internet/private/vendor-objects/lancomSystems/switchingSystems/gigabitEthernetSwitches/lancomGS2326plus/gs2326plusSecurity/gs2326plusNAS/gs2326plusNASConfiguration/gs2326plusNASPortConfigTable/gs2326plusNASPortConfigEntry/gs2326plusNASPortConfigRADIUSAssignedVLANEnabled
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current

Enumerated values

ValueName
0disable
1enable

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In LANCOM-GS-2326PLUS-MIB, the row index gs2326plusNASPortConfigPort is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.4.<gs2326plusNASPortConfigPort>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.4

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

gs2326plusNASPortConfigRADIUSAssignedVLANEnabled · current

gs2326plusNASPortConfigRADIUSAssignedVLANEnabled OBJECT-TYPE
   SYNTAX      INTEGER { disable(0), enable(1) }
   MAX-ACCESS  read-write
   STATUS      current
   DESCRIPTION
       "When RADIUS-Assigned VLAN is both globally enabled and enabled (checked) 
	   for a given port, the switch reacts to VLAN ID information carried in the 
	   RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant 
	   is successfully authenticated. If present and valid, the port's Port VLAN ID 
	   will be changed to this VLAN ID, the port will be set to be a member of that 
	   VLAN ID, and the port will be forced into VLAN unaware mode. Once assigned, 
	   all traffic arriving on the port will be classified and switched on the 
	   RADIUS-assigned VLAN ID.
	   Admin State supported : Port-based and Single 802.1X and MAC-based Single Auth."
   ::= { gs2326plusNASPortConfigEntry 4 }

gs2326plusNASPortConfigRADIUSAssignedVLANEnabled · current

gs2326plusNASPortConfigRADIUSAssignedVLANEnabled OBJECT-TYPE
   SYNTAX      INTEGER { disable(0), enable(1) }
   MAX-ACCESS  read-write
   STATUS      current
   DESCRIPTION
       "When RADIUS-Assigned VLAN is both globally enabled and enabled (checked) 
	   for a given port, the switch reacts to VLAN ID information carried in the 
	   RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant 
	   is successfully authenticated. If present and valid, the port's Port VLAN ID 
	   will be changed to this VLAN ID, the port will be set to be a member of that 
	   VLAN ID, and the port will be forced into VLAN unaware mode. Once assigned, 
	   all traffic arriving on the port will be classified and switched on the 
	   RADIUS-assigned VLAN ID.
	   Admin State supported : Port-based and Single 802.1X."
   ::= { gs2326plusNASPortConfigEntry 4 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

When RADIUS-Assigned VLAN is both globally enabled and enabled (checked) for a given port, the switch reacts to VLAN ID information carried in the RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant is successfully authenticated. If present and valid, the port's Port VLAN ID will be changed to this VLAN ID, the port will be set to be a member of that VLAN ID, and the port will be forced into VLAN unaware mode. Once assigned, all traffic arriving on the port will be classified and switched on the RADIUS-assigned VLAN ID. Admin State supported : Port-based and Single 802.1X and MAC-based Single Auth.

Sources for this description

LANCOM official release MIBsLANCOM MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

When RADIUS-Assigned VLAN is both globally enabled and enabled (checked) for a given port, the switch reacts to VLAN ID information carried in the RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant is successfully authenticated. If present and valid, the port's Port VLAN ID will be changed to this VLAN ID, the port will be set to be a member of that VLAN ID, and the port will be forced into VLAN unaware mode. Once assigned, all traffic arriving on the port will be classified and switched on the RADIUS-assigned VLAN ID. Admin State supported : Port-based and Single 802.1X.

Sources for this description

LANCOM official release MIBs

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1LANCOM official release MIBs, LANCOM MIB copies (LibreNMS/Observium Community)1 record · 10 sources

Description 1

gs2326plusNASPortConfigRADIUSAssignedVLANEnabled · currentLANCOM official release MIBs, LANCOM MIB copies (LibreNMS/Observium Community)10 sources

Status in source: current.

Names: gs2326plusNASPortConfigRADIUSAssignedVLANEnabled

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "gs2326plusNASPortConfigRADIUSAssignedVLANEnabled",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "disable",
    "(",
    "0",
    ")",
    ",",
    "enable",
    "(",
    "1",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"When RADIUS-Assigned VLAN is both globally enabled and enabled (checked) for a given port, the switch reacts to VLAN ID information carried in the RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant is successfully authenticated. If present and valid, the port's Port VLAN ID will be changed to this VLAN ID, the port will be set to be a member of that VLAN ID, and the port will be forced into VLAN unaware mode. Once assigned, all traffic arriving on the port will be classified and switched on the RADIUS-assigned VLAN ID. Admin State supported : Port-based and Single 802.1X and MAC-based Single Auth.\"",
    "::=",
    "{",
    "gs2326plusNASPortConfigEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "disable",
            0
          ],
          [
            "enable",
            1
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "When RADIUS-Assigned VLAN is both globally enabled and enabled (checked) for a given port, the switch reacts to VLAN ID information carried in the RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant is successfully authenticated. If present and valid, the port's Port VLAN ID will be changed to this VLAN ID, the port will be set to be a member of that VLAN ID, and the port will be forced into VLAN unaware mode. Once assigned, all traffic arriving on the port will be classified and switched on the RADIUS-assigned VLAN ID. Admin State supported : Port-based and Single 802.1X and MAC-based Single Auth."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2LANCOM official release MIBs1 record · 3 sources

Description 2

gs2326plusNASPortConfigRADIUSAssignedVLANEnabled · currentLANCOM official release MIBs3 sources

Status in source: current.

Names: gs2326plusNASPortConfigRADIUSAssignedVLANEnabled

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "gs2326plusNASPortConfigRADIUSAssignedVLANEnabled",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "disable",
    "(",
    "0",
    ")",
    ",",
    "enable",
    "(",
    "1",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"When RADIUS-Assigned VLAN is both globally enabled and enabled (checked) for a given port, the switch reacts to VLAN ID information carried in the RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant is successfully authenticated. If present and valid, the port's Port VLAN ID will be changed to this VLAN ID, the port will be set to be a member of that VLAN ID, and the port will be forced into VLAN unaware mode. Once assigned, all traffic arriving on the port will be classified and switched on the RADIUS-assigned VLAN ID. Admin State supported : Port-based and Single 802.1X.\"",
    "::=",
    "{",
    "gs2326plusNASPortConfigEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "disable",
            0
          ],
          [
            "enable",
            1
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "When RADIUS-Assigned VLAN is both globally enabled and enabled (checked) for a given port, the switch reacts to VLAN ID information carried in the RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant is successfully authenticated. If present and valid, the port's Port VLAN ID will be changed to this VLAN ID, the port will be set to be a member of that VLAN ID, and the port will be forced into VLAN unaware mode. Once assigned, all traffic arriving on the port will be classified and switched on the RADIUS-assigned VLAN ID. Admin State supported : Port-based and Single 802.1X."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.2356)

Udo Brocker

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.1 gs2326plusNASPortConfigPort00
1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.2 gs2326plusNASPortConfigAdminState00
1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.3 gs2326plusNASPortConfigRADIUSAssignedQoSEnabled00
1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.5 gs2326plusNASPortConfigGuestVLANEnabled00
1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.6 gs2326plusNASPortConfigPortState00
1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.7 gs2326plusNASPortConfigReauthenticate00
1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.8 gs2326plusNASPortConfigReinitialize00
1.3.6.1.4.1.2356.800.3.2329.3.11.1.13.1.101 gs2326plusNASPortConfigFallbackEnabled00