diConfig

1.3.6.1.4.1.24062.2.2.1.10.1.1.1.2

Description

Select the type of fault event that triggers the relay. To config a fault relay, first select the founction this relay serves for, then configure the condition that triggers the relay in detail. At last, set the faultRelayEntryStatus to active(1) or nonActive(3) to enable or disable the setting on the relay.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.24062.2.2.1.10.1.1.1 (faultRelayEntry)
Node code
2
Node names
  • diConfig
  • faultSelection
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.2
URN notation
urn:oid:1.3.6.1.4.1.24062.2.2.1.10.1.1.1.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 24062 2 2 1 10 1 1 1 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) diConfig(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) faultSelection(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) diConfig(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) faultSelection(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) diConfig(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) faultSelection(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) diConfig(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) faultSelection(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) diConfig(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) faultSelection(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) diConfig(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) faultSelection(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) diConfig(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) faultSelection(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) diConfig(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) korenix(24062) products(2) managedFESwitch(2) jetnet5010G(1) warning(10) faultRelay(1) faultRelayTable(1) faultRelayEntry(1) faultSelection(2)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/24062/2/2/1/10/1/1/1/2
  • /ISO/Identified-Organization/6/1/4/1/24062/2/2/1/10/1/1/1/2
  • /ISO/3/6/1/4/1/24062/2/2/1/10/1/1/1/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/24062/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/diConfig
  • /iso/identified-organization/dod/internet/private/enterprise/24062/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/faultSelection
  • /iso/identified-organization/dod/internet/private/enterprise/korenix/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/diConfig
  • /iso/identified-organization/dod/internet/private/enterprise/korenix/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/faultSelection
  • /iso/identified-organization/dod/internet/private/enterprises/24062/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/diConfig
  • /iso/identified-organization/dod/internet/private/enterprises/24062/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/faultSelection
  • /iso/identified-organization/dod/internet/private/enterprises/korenix/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/diConfig
  • /iso/identified-organization/dod/internet/private/enterprises/korenix/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/faultSelection
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/24062/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/diConfig
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/24062/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/faultSelection
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/korenix/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/diConfig
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/korenix/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/faultSelection
  • /iso/identified-organization/dod/internet/private/vendor-objects/24062/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/diConfig
  • /iso/identified-organization/dod/internet/private/vendor-objects/24062/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/faultSelection
  • /iso/identified-organization/dod/internet/private/vendor-objects/korenix/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/diConfig
  • /iso/identified-organization/dod/internet/private/vendor-objects/korenix/products/managedFESwitch/jetnet5010G/warning/faultRelay/faultRelayTable/faultRelayEntry/faultSelection
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Netdisco MIB archive copies

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current

Enumerated values

Numbers refer to source variants above. Each value is shown only for variants that define it.

ValueNameSource variants
1di1Low2
1diState1
2di1High2
2dryOutput1
3di2Low2
3powerFailure1
4di2High2
4linkFailure1
5disable2
5pingFailure1
6superRingFailure1

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In Jetnet5010G, the row index faultRelayId is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.24062.2.2.1.10.1.1.1.2.<faultRelayId>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.24062.2.2.1.10.1.1.1.2

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

faultSelection · current

faultSelection OBJECT-TYPE
    SYNTAX      INTEGER {
                    diState(1),
                    dryOutput(2),
                    powerFailure(3),
                    linkFailure(4),
                    pingFailure(5),
                    superRingFailure(6)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "Select the type of fault event that triggers the relay. 
                 To config a fault relay, first select the founction this
                 relay serves for, then configure the condition that 
                 triggers the relay in detail. At last, set the 
                 faultRelayEntryStatus to active(1) or nonActive(3) to
                 enable or disable the setting on the relay."
    ::= { faultRelayEntry 2 }

diConfig · current

diConfig OBJECT-TYPE
    SYNTAX      INTEGER {
                    di1Low(1),
                    di1High(2),
                    di2Low(3),
                    di2High(4),
                    disable(5)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "The fault relay will be triggered if digital input is low
                or high."
    ::= { faultRelayEntry 2 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Select the type of fault event that triggers the relay. To config a fault relay, first select the founction this relay serves for, then configure the condition that triggers the relay in detail. At last, set the faultRelayEntryStatus to active(1) or nonActive(3) to enable or disable the setting on the relay.

Sources for this description

Netdisco MIB archive copies

See 1 matching source record

Description 2

The fault relay will be triggered if digital input is low or high.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Netdisco MIB archive copies1 record · 1 source

Description 1

faultSelection · currentNetdisco MIB archive copies1 source

Status in source: current.

Names: faultSelection

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "faultSelection",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "diState",
    "(",
    "1",
    ")",
    ",",
    "dryOutput",
    "(",
    "2",
    ")",
    ",",
    "powerFailure",
    "(",
    "3",
    ")",
    ",",
    "linkFailure",
    "(",
    "4",
    ")",
    ",",
    "pingFailure",
    "(",
    "5",
    ")",
    ",",
    "superRingFailure",
    "(",
    "6",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Select the type of fault event that triggers the relay. To config a fault relay, first select the founction this relay serves for, then configure the condition that triggers the relay in detail. At last, set the faultRelayEntryStatus to active(1) or nonActive(3) to enable or disable the setting on the relay.\"",
    "::=",
    "{",
    "faultRelayEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "diState",
            1
          ],
          [
            "dryOutput",
            2
          ],
          [
            "powerFailure",
            3
          ],
          [
            "linkFailure",
            4
          ],
          [
            "pingFailure",
            5
          ],
          [
            "superRingFailure",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Select the type of fault event that triggers the relay. To config a fault relay, first select the founction this relay serves for, then configure the condition that triggers the relay in detail. At last, set the faultRelayEntryStatus to active(1) or nonActive(3) to enable or disable the setting on the relay."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

diConfig · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: diConfig

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "diConfig",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "di1Low",
    "(",
    "1",
    ")",
    ",",
    "di1High",
    "(",
    "2",
    ")",
    ",",
    "di2Low",
    "(",
    "3",
    ")",
    ",",
    "di2High",
    "(",
    "4",
    ")",
    ",",
    "disable",
    "(",
    "5",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The fault relay will be triggered if digital input is low or high.\"",
    "::=",
    "{",
    "faultRelayEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "di1Low",
            1
          ],
          [
            "di1High",
            2
          ],
          [
            "di2Low",
            3
          ],
          [
            "di2High",
            4
          ],
          [
            "disable",
            5
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The fault relay will be triggered if digital input is low or high."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.24062)

Uwai Chen

Siblings (13)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.1 faultRelayId00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.3 dryOutputConfig, diConfig00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.4 dryOutputOnPeriod, dryOutputOnPeriodConfig00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.5 dryOutputOffPeriod, dryOutputOffPeriodConfig00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.6 powerFailureConfig00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.7 linkFailureConfig00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.8 pingConfig, pingFailureIP00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.9 pingIP, pingResetTime00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.10 pingResetConfig, pingHoldTime00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.11 pingResetIP, faultRelayEntryStatus00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.12 pingResetTime00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.13 pingResetHoldTime00
1.3.6.1.4.1.24062.2.2.1.10.1.1.1.14 ringFailureConfig00