Reset the ping process after pingResetTime, and then wait pingHoldTime to ping again.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.24062.2.2.3.10.1.1.1.12
Reset the ping process after pingResetTime, and then wait pingHoldTime to ping again.
Identification
{1 3 6 1 4 1 24062 2 2 3 10 1 1 1 12}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In Jetnet4510, the row index faultRelayId is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.24062.2.2.3.10.1.1.1.12.<faultRelayId>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.24062.2.2.3.10.1.1.1.12
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
pingResetTime OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Reset the ping process after pingResetTime, and then wait
pingHoldTime to ping again."
::= { faultRelayEntry 12 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Reset the ping process after pingResetTime, and then wait pingHoldTime to ping again.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: pingResetTime
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pingResetTime",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"1",
".",
".",
"65535",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Reset the ping process after pingResetTime, and then wait pingHoldTime to ping again.\"",
"::=",
"{",
"faultRelayEntry",
"12",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
1,
65535
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Reset the ping process after pingResetTime, and then wait pingHoldTime to ping again."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: Jetnet4510
See published definition above
{'SNMPv2-TC': ['RowStatus', 'DisplayString', 'MacAddress', 'TimeInterval'], 'RFC1155-SMI': ['internet'], 'Q-BRIDGE-MIB': ['PortList']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.1 | faultRelayId | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.2 | diConfig | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.3 | dryOutputConfig | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.4 | dryOutputOnPeriod | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.5 | dryOutputOffPeriod | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.6 | powerFailureConfig | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.7 | linkFailureConfig | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.8 | pingConfig | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.9 | pingIP | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.10 | pingResetConfig | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.11 | pingResetIP | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.13 | pingResetHoldTime | 0 | 0 | |
| 1.3.6.1.4.1.24062.2.2.3.10.1.1.1.14 | ringFailureConfig | 0 | 0 |