OID reference

hm2DPIProfileModbusFunctionCodeList

1.3.6.1.4.1.248.11.79.1.3.21.1.1.4

Description

The function codes for this enforcer as string. A function code has the syntax: <val> Function codes are separated by a comma. If more than one value is given for a function code, values are separated by a | -sign (pipe). Following function codes are defined: <1..255>|<0-65535>|<0-65535> (apply to packets with given f…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.248.11.79.1.3.21.1.1 (hm2DPIProfileModbusEntry)
Node code
4
Node name
hm2DPIProfileModbusFunctionCodeList
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.248.11.79.1.3.21.1.1.4
URN notation
urn:oid:1.3.6.1.4.1.248.11.79.1.3.21.1.1.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 248 11 79 1 3 21 1 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hirschmann(248) hm2ConfigurationMibs(11) hm2FwMib(79) hm2FwObjects(1) hm2L3Fw(3) hm2DPIProfileTables(21) hm2DPIProfileModbusTable(1) hm2DPIProfileModbusEntry(1) hm2DPIProfileModbusFunctionCodeList(4)}
OID-IRI notation
  • /1/3/6/1/4/1/248/11/79/1/3/21/1/1/4
  • /ISO/Identified-Organization/6/1/4/1/248/11/79/1/3/21/1/1/4
  • /ISO/3/6/1/4/1/248/11/79/1/3/21/1/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/identified-organization/dod/internet/private/enterprises/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/identified-organization/dod/internet/private/vendor-objects/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/org/dod/internet/private/enterprise/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/org/dod/internet/private/enterprises/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/org/dod/internet/private/ldap-enterprise/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/org/dod/internet/private/vendor-objects/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/iso-identified-organization/dod/internet/private/enterprise/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/iso-organization/dod/internet/private/enterprise/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/iso-organization/dod/internet/private/enterprises/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList
  • /iso/iso-organization/dod/internet/private/vendor-objects/hirschmann/hm2ConfigurationMibs/hm2FwMib/hm2FwObjects/hm2L3Fw/hm2DPIProfileTables/hm2DPIProfileModbusTable/hm2DPIProfileModbusEntry/hm2DPIProfileModbusFunctionCodeList

SNMP properties

Value type
HmExtraLargeDisplayString
Maximum access defined by MIB
read-create
Status in MIB
current
Default value
"1,2,3,4,7,11,12,17,20,24"
Allowed size (octets)
1–1400

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In HM2-FW-MIB, the row index hm2DPIProfileModbusIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.248.11.79.1.3.21.1.1.4.<hm2DPIProfileModbusIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.248.11.79.1.3.21.1.1.4

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

hm2DPIProfileModbusFunctionCodeList · current

hm2DPIProfileModbusFunctionCodeList OBJECT-TYPE
	 SYNTAX HmExtraLargeDisplayString ( SIZE(1..1400) )
 	 MAX-ACCESS read-create
 	 STATUS current
 	 DESCRIPTION
		"The function codes for this enforcer as string.
		A function code has the syntax:
			<val>
		Function codes are separated by a comma.
		If more than one value is given for a function code, values are
		separated by a | -sign (pipe).
		Following function codes are defined:
			<1..255>|<0-65535>|<0-65535> (apply to packets with given function codes <1..255>, address range <0-65535>, address range <0-65535>)
			1|<0-65535> (apply to packets with given function code read coils, coil address range <0-65535>)
			2|<0-65535> (apply to packets with given function code read discrete inputs, input address range <0-65535>)
			3|<0-65535> (apply to packets with given function code read holding registers, register address range <0-65535>)
			4|<0-65535> (apply to packets with given function code read input registers, register address range <0-65535>)
			5|<0-65535> (apply to packets with given function code write single coil, coil address range <0-65535>)
			6|<0-65535> (apply to packets with given function code write single register, register address range <0-65535>)
			7 (apply to packets with given function code read exception status)
			8 (apply to packets with given function code diagnostic)
			11 (apply to packets with given function code get com event counter)
			12 (apply to packets with given function code get comm event log)
			13 (apply to packets with given function code program (584/984))
			14 (apply to packets with given function code poll (584/984))
			15|<0-65535> (apply to packets with given function code write multiple coils, coil address range <0-65535>)
			16|<0-65535> (apply to packets with given function code write multiple registers, register address range <0-65535>)
			17 (apply to packets with given function code report slave id)
			20 (apply to packets with given function code read file record)
			21 (apply to packets with given function code write file record)
			22|<0-65535> (apply to packets with given function code mask write register, register address range <0-65535>)
			23|<0-65535>|<0-65535> (apply to packets with given function code read/write multiple registers, read address range <0-65535>, write address range <0-65535>)
			24|<0-65535> (apply to packets with given function code read fifo queue, pointer address range <0-65535>)
			40 (apply to packets with given function code program (concept))
			42 (apply to packets with given function code concept symbol table)
			43 (apply to packets with given function code encapsulated interface transport)
			48 (apply to packets with given function code advantech co. ltd. - management functions)
			66 (apply to packets with given function code scan data inc. - expanded read holding registers)
			67 (apply to packets with given function code scan data inc. - expanded write holding registers)
			90 (apply to packets with given function code unity programming/ofs)
			100 (apply to packets with given function code scattered register read)
			125 (apply to packets with given function code schneider electric - firmware replacement)
			126 (apply to packets with given function code schneider electric - program)"
	DEFVAL  { "1,2,3,4,7,11,12,17,20,24" }
	::= { hm2DPIProfileModbusEntry 4 }

hm2DPIProfileModbusFunctionCodeList · current

hm2DPIProfileModbusFunctionCodeList OBJECT-TYPE
	 SYNTAX HmExtraLargeDisplayString ( SIZE(1..1400) )
 	 MAX-ACCESS read-create
 	 STATUS current
 	 DESCRIPTION
		"The function codes for this enforcer as string.
		A function code has the syntax:
			<val>
		Function codes are separated by a comma.
		If more than one value is given for a function code, values are
		separated by a | -sign (pipe).
		Following function codes are defined:
			<1..255>|<0-65535>|<0-65535> (apply to packets with given function codes <1..255>, address range <0-65535>, address range <0-65535>)
			1|<0-65535> (apply to packets with given function code read coils, coil address range <0-65535>)
			2|<0-65535> (apply to packets with given function code read discrete inputs, input address range <0-65535>)
			3|<0-65535> (apply to packets with given function code read holding registers, register address range <0-65535>)
			4|<0-65535> (apply to packets with given function code read input registers, register address range <0-65535>)
			5|<0-65535> (apply to packets with given function code write single coil, coil address range <0-65535>)
			6|<0-65535> (apply to packets with given function code write single register, register address range <0-65535>)
			7 (apply to packets with given function code read exception status)
			8 (apply to packets with given function code diagnostic)
			11 (apply to packets with given function code get com event counter)
			12 (apply to packets with given function code get comm event log)
			13 (apply to packets with given function code program (584/984))
			14 (apply to packets with given function code poll (584/984))
			15|<0-65535> (apply to packets with given function code write multiple coils, coil address range <0-65535>)
			16|<0-65535> (apply to packets with given function code write multiple registers, register address range <0-65535>)
			17 (apply to packets with given function code report slave id)
			20 (apply to packets with given function code read file record)
			21 (apply to packets with given function code write file record)
			22|<0-65535> (apply to packets with given function code mask write register, register address range <0-65535>)
			23|<0-65535>|<0-65535> (apply to packets with given function code read/write multiple registers, read address range <0-65535>, write address range <0-65535>)
			24|<0-65535> (apply to packets with given function code read fifo queue, pointer address range <0-65535>)
			40 (apply to packets with given function code program (concept))
			42 (apply to packets with given function code concept symbol table)
			43 (apply to packets with given function code encapsulated interface transport)
			48 (apply to packets with given function code advantech co. ltd. - management functions)
			66 (apply to packets with given function code scan data inc. - expanded read holding registers)
			67 (apply to packets with given function code scan data inc. - expanded write holding registers)
			90 (apply to packets with given function code unity programming/ofs)
			100 (apply to packets with given function code scattered register read)
			125 (apply to packets with given function code schneider electric - firmware replacement)
			126 (apply to packets with given function code schneider electric - program)"
	DEFVAL  { "1,2,3,4,7,11,12,17,20,24" }
	::= { hm2DPIProfileModbusEntry 4 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The function codes for this enforcer as string. A function code has the syntax: <val> Function codes are separated by a comma. If more than one value is given for a function code, values are separated by a | -sign (pipe). Following function codes are defined: <1..255>|<0-65535>|<0-65535> (apply to packets with given function codes <1..255>, address range <0-65535>, address range <0-65535>) 1|<0-65535> (apply to packets with given function code read coils, coil address range <0-65535>) 2|<0-65535> (apply to packets with given function code read discrete inputs, input address range <0-65535>) 3|<0-65535> (apply to packets with given function code read holding registers, register address range <0-65535>) 4|<0-65535> (apply to packets with given function code read input registers, register address range <0-65535>) 5|<0-65535> (apply to packets with given function code write single coil, coil address range <0-65535>) 6|<0-65535> (apply to packets with given function code write single register, register address range <0-65535>) 7 (apply to packets with given function code read exception status) 8 (apply to packets with given function code diagnostic) 11 (apply to packets with given function code get com event counter) 12 (apply to packets with given function code get comm event log) 13 (apply to packets with given function code program (584/984)) 14 (apply to packets with given function code poll (584/984)) 15|<0-65535> (apply to packets with given function code write multiple coils, coil address range <0-65535>) 16|<0-65535> (apply to packets with given function code write multiple registers, register address range <0-65535>) 17 (apply to packets with given function code report slave id) 20 (apply to packets with given function code read file record) 21 (apply to packets with given function code write file record) 22|<0-65535> (apply to packets with given function code mask write register, register address range <0-65535>) 23|<0-65535>|<0-65535> (apply to packets with given function code read/write multiple registers, read address range <0-65535>, write address range <0-65535>) 24|<0-65535> (apply to packets with given function code read fifo queue, pointer address range <0-65535>) 40 (apply to packets with given function code program (concept)) 42 (apply to packets with given function code concept symbol table) 43 (apply to packets with given function code encapsulated interface transport) 48 (apply to packets with given function code advantech co. ltd. - management functions) 66 (apply to packets with given function code scan data inc. - expanded read holding registers) 67 (apply to packets with given function code scan data inc. - expanded write holding registers) 90 (apply to packets with given function code unity programming/ofs) 100 (apply to packets with given function code scattered register read) 125 (apply to packets with given function code schneider electric - firmware replacement) 126 (apply to packets with given function code schneider electric - program)

Sources for this description

Belden, GarrettCom and Hirschmann IT official standalone MIBsHirschmann MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Belden, GarrettCom and Hirschmann IT official standalone MIBs, Hirschmann MIB copies (LibreNMS/Observium Community)1 record · 5 sources

Description 1

hm2DPIProfileModbusFunctionCodeList · currentBelden, GarrettCom and Hirschmann IT official standalone MIBs, Hirschmann MIB copies (LibreNMS/Observium Community)5 sources

Status in source: current.

Names: hm2DPIProfileModbusFunctionCodeList

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "hm2DPIProfileModbusFunctionCodeList",
    "OBJECT-TYPE",
    "SYNTAX",
    "HmExtraLargeDisplayString",
    "(",
    "SIZE",
    "(",
    "1",
    ".",
    ".",
    "1400",
    ")",
    ")",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The function codes for this enforcer as string. A function code has the syntax: <val> Function codes are separated by a comma. If more than one value is given for a function code, values are separated by a | -sign (pipe). Following function codes are defined: <1..255>|<0-65535>|<0-65535> (apply to packets with given function codes <1..255>, address range <0-65535>, address range <0-65535>) 1|<0-65535> (apply to packets with given function code read coils, coil address range <0-65535>) 2|<0-65535> (apply to packets with given function code read discrete inputs, input address range <0-65535>) 3|<0-65535> (apply to packets with given function code read holding registers, register address range <0-65535>) 4|<0-65535> (apply to packets with given function code read input registers, register address range <0-65535>) 5|<0-65535> (apply to packets with given function code write single coil, coil address range <0-65535>) 6|<0-65535> (apply to packets with given function code write single register, register address range <0-65535>) 7 (apply to packets with given function code read exception status) 8 (apply to packets with given function code diagnostic) 11 (apply to packets with given function code get com event counter) 12 (apply to packets with given function code get comm event log) 13 (apply to packets with given function code program (584/984)) 14 (apply to packets with given function code poll (584/984)) 15|<0-65535> (apply to packets with given function code write multiple coils, coil address range <0-65535>) 16|<0-65535> (apply to packets with given function code write multiple registers, register address range <0-65535>) 17 (apply to packets with given function code report slave id) 20 (apply to packets with given function code read file record) 21 (apply to packets with given function code write file record) 22|<0-65535> (apply to packets with given function code mask write register, register address range <0-65535>) 23|<0-65535>|<0-65535> (apply to packets with given function code read/write multiple registers, read address range <0-65535>, write address range <0-65535>) 24|<0-65535> (apply to packets with given function code read fifo queue, pointer address range <0-65535>) 40 (apply to packets with given function code program (concept)) 42 (apply to packets with given function code concept symbol table) 43 (apply to packets with given function code encapsulated interface transport) 48 (apply to packets with given function code advantech co. ltd. - management functions) 66 (apply to packets with given function code scan data inc. - expanded read holding registers) 67 (apply to packets with given function code scan data inc. - expanded write holding registers) 90 (apply to packets with given function code unity programming/ofs) 100 (apply to packets with given function code scattered register read) 125 (apply to packets with given function code schneider electric - firmware replacement) 126 (apply to packets with given function code schneider electric - program)\"",
    "DEFVAL",
    "{",
    [
      "literal",
      "22312c322c332c342c372c31312c31322c31372c32302c323422"
    ],
    "}",
    "::=",
    "{",
    "hm2DPIProfileModbusEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "HmExtraLargeDisplayString",
      [
        "octetStringSubType",
        [
          [
            1,
            1400
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The function codes for this enforcer as string. A function code has the syntax: <val> Function codes are separated by a comma. If more than one value is given for a function code, values are separated by a | -sign (pipe). Following function codes are defined: <1..255>|<0-65535>|<0-65535> (apply to packets with given function codes <1..255>, address range <0-65535>, address range <0-65535>) 1|<0-65535> (apply to packets with given function code read coils, coil address range <0-65535>) 2|<0-65535> (apply to packets with given function code read discrete inputs, input address range <0-65535>) 3|<0-65535> (apply to packets with given function code read holding registers, register address range <0-65535>) 4|<0-65535> (apply to packets with given function code read input registers, register address range <0-65535>) 5|<0-65535> (apply to packets with given function code write single coil, coil address range <0-65535>) 6|<0-65535> (apply to packets with given function code write single register, register address range <0-65535>) 7 (apply to packets with given function code read exception status) 8 (apply to packets with given function code diagnostic) 11 (apply to packets with given function code get com event counter) 12 (apply to packets with given function code get comm event log) 13 (apply to packets with given function code program (584/984)) 14 (apply to packets with given function code poll (584/984)) 15|<0-65535> (apply to packets with given function code write multiple coils, coil address range <0-65535>) 16|<0-65535> (apply to packets with given function code write multiple registers, register address range <0-65535>) 17 (apply to packets with given function code report slave id) 20 (apply to packets with given function code read file record) 21 (apply to packets with given function code write file record) 22|<0-65535> (apply to packets with given function code mask write register, register address range <0-65535>) 23|<0-65535>|<0-65535> (apply to packets with given function code read/write multiple registers, read address range <0-65535>, write address range <0-65535>) 24|<0-65535> (apply to packets with given function code read fifo queue, pointer address range <0-65535>) 40 (apply to packets with given function code program (concept)) 42 (apply to packets with given function code concept symbol table) 43 (apply to packets with given function code encapsulated interface transport) 48 (apply to packets with given function code advantech co. ltd. - management functions) 66 (apply to packets with given function code scan data inc. - expanded read holding registers) 67 (apply to packets with given function code scan data inc. - expanded write holding registers) 90 (apply to packets with given function code unity programming/ofs) 100 (apply to packets with given function code scattered register read) 125 (apply to packets with given function code schneider electric - firmware replacement) 126 (apply to packets with given function code schneider electric - program)"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "\"1,2,3,4,7,11,12,17,20,24\""
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.248)

Nisi Heinz

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.248.11.79.1.3.21.1.1.1 hm2DPIProfileModbusIndex00
1.3.6.1.4.1.248.11.79.1.3.21.1.1.2 hm2DPIProfileModbusDescription00
1.3.6.1.4.1.248.11.79.1.3.21.1.1.3 hm2DPIProfileModbusFunctionType00
1.3.6.1.4.1.248.11.79.1.3.21.1.1.5 hm2DPIProfileModbusUnitIdentifierList00
1.3.6.1.4.1.248.11.79.1.3.21.1.1.6 hm2DPIProfileModbusSanityCheck00
1.3.6.1.4.1.248.11.79.1.3.21.1.1.7 hm2DPIProfileModbusException00
1.3.6.1.4.1.248.11.79.1.3.21.1.1.8 hm2DPIProfileModbusReset00
1.3.6.1.4.1.248.11.79.1.3.21.1.1.9 hm2DPIProfileModbusRowStatus00