Status in source: current.
Names: hm2DPIS7RuleSubFunction
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hm2DPIS7RuleSubFunction",
"OBJECT-TYPE",
"SYNTAX",
"HmLargeDisplayString",
"(",
"SIZE",
"(",
"1",
".",
".",
"160",
")",
")",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"Multiple sub function codes can be listed separated by a comma (',') - single sub function code (eg: 0x00) - comma separated list of sub function codes (eg: 0x01,0x02,0x0C) - sub function code starts 0x00 and cannot be greater than 0xFF - keyword 'all' for including each sub function in a function group. - keyword 'any' for allowing any sub function in a function group. A few of the defined sub function groups corresponfing to their function group are listed below: Names of userdata subfunctions in group 1 (Programmer commands) -Block status 0x01 -Variable status 0x02 -Output ISTACK 0x03 -Output BSTACK 0x04 -Output LSTACK 0x05 -Time measurement from to 0x06 -Force selection 0x07 -Modify variable 0x08 -Force 0x09 -Breakpoint 0x0a -Exit HOLD 0x0b -Memory reset 0x0c -Disable job 0x0d -Enable job 0x0e -Delete job 0x0f -Read job list 0x10 -Read job 0x11 -Replace job 0x12 -Block status v2 0x13 -Flash LED 0x16 Names of userdata subfunctions in group 2 (Cyclic services) -Cyclic transfer 0x01 -Unsubscribe 0x04 -Change driven transfer 0x05 -Change driven transfer modify 0x07 -RDREC 0x08 Names of userdata subfunctions in group 3 (Block functions) -List blocks 0x01 -List blocks of type 0x02 -Get block info 0x03 Names of userdata subfunctions in group 4 (CPU functions) -Read SZL 0x01 -Message service 0x02 -Diagnostic message 0x03 -ALARM_8 indication 0x05 -NOTIFY indication 0x06 -ALARM_8 lock 0x07 -ALARM_8 unlock 0x08 -SCAN indication 0x09 -AR_SEND indication 0x10 -ALARM ack 0x0b -ALARM ack indication 0x0c -ALARM lock indication 0x0d -ALARM unlock indication 0x0e -ALARM_SQ indication 0x11 -ALARM_S indication 0x12 -ALARM query 0x13 -NOTIFY_8 indication 0x16 Names of userdata subfunctions in group 5 (Security?) -PLC password define 0x01 Name of userdata Subfunctions in group 6 (PBC BSEND) -PBC BSEND sub-function 0x01 Names of userdata subfunctions in group 7 (Time functions) -Read clock 0x01 -Set clock 0x02 -Read clock (following) 0x03 -Set clock 0x04 Name of Subfunctions only used in group NC programming (0x3f) -Request download 0x01 -Download block 0x02 -Continue download 0x03 -Download ended 0x04 -Start upload 0x06 -Upload 0x07 -Continue upload 0x08 Name of Subfunctions for Data Record Routing to Profibus (0x20) -DRR Init 0x01 -DRR Finish 0x02 -DRR Data 0x03\"",
"DEFVAL",
"{",
[
"literal",
"222d22"
],
"}",
"::=",
"{",
"hm2DPIS7RuleEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"HmLargeDisplayString",
[
"octetStringSubType",
[
[
1,
160
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Multiple sub function codes can be listed separated by a comma (',') - single sub function code (eg: 0x00) - comma separated list of sub function codes (eg: 0x01,0x02,0x0C) - sub function code starts 0x00 and cannot be greater than 0xFF - keyword 'all' for including each sub function in a function group. - keyword 'any' for allowing any sub function in a function group. A few of the defined sub function groups corresponfing to their function group are listed below: Names of userdata subfunctions in group 1 (Programmer commands) -Block status 0x01 -Variable status 0x02 -Output ISTACK 0x03 -Output BSTACK 0x04 -Output LSTACK 0x05 -Time measurement from to 0x06 -Force selection 0x07 -Modify variable 0x08 -Force 0x09 -Breakpoint 0x0a -Exit HOLD 0x0b -Memory reset 0x0c -Disable job 0x0d -Enable job 0x0e -Delete job 0x0f -Read job list 0x10 -Read job 0x11 -Replace job 0x12 -Block status v2 0x13 -Flash LED 0x16 Names of userdata subfunctions in group 2 (Cyclic services) -Cyclic transfer 0x01 -Unsubscribe 0x04 -Change driven transfer 0x05 -Change driven transfer modify 0x07 -RDREC 0x08 Names of userdata subfunctions in group 3 (Block functions) -List blocks 0x01 -List blocks of type 0x02 -Get block info 0x03 Names of userdata subfunctions in group 4 (CPU functions) -Read SZL 0x01 -Message service 0x02 -Diagnostic message 0x03 -ALARM_8 indication 0x05 -NOTIFY indication 0x06 -ALARM_8 lock 0x07 -ALARM_8 unlock 0x08 -SCAN indication 0x09 -AR_SEND indication 0x10 -ALARM ack 0x0b -ALARM ack indication 0x0c -ALARM lock indication 0x0d -ALARM unlock indication 0x0e -ALARM_SQ indication 0x11 -ALARM_S indication 0x12 -ALARM query 0x13 -NOTIFY_8 indication 0x16 Names of userdata subfunctions in group 5 (Security?) -PLC password define 0x01 Name of userdata Subfunctions in group 6 (PBC BSEND) -PBC BSEND sub-function 0x01 Names of userdata subfunctions in group 7 (Time functions) -Read clock 0x01 -Set clock 0x02 -Read clock (following) 0x03 -Set clock 0x04 Name of Subfunctions only used in group NC programming (0x3f) -Request download 0x01 -Download block 0x02 -Continue download 0x03 -Download ended 0x04 -Start upload 0x06 -Upload 0x07 -Continue upload 0x08 Name of Subfunctions for Data Record Routing to Profibus (0x20) -DRR Init 0x01 -DRR Finish 0x02 -DRR Data 0x03"
],
null,
null,
null,
[
"DEFVAL",
"\"-\""
]
]
}
- Belden, GarrettCom and Hirschmann IT official standalone MIBs
· Publisher's source file: HiSecOS-05200-EAGLE4003.zip — HiSecOS-05200-EAGLE4003/MIBs/HM2-FW-MIB.mib
Module: HM2-FW-MIB
See published definition above
Module imports
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['RowStatus', 'DisplayString', 'TruthValue', 'MacAddress'], 'HM2-TC-MIB': ['hm2ConfigurationMibs', 'HmActionValue', 'HmTimeSeconds1970', 'HmEnabledStatus', 'HmLargeDisplayString', 'HmExtraLargeDisplayString'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Integer32', 'Unsigned32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'HM2-PLATFORM-QOS-ACL-MIB': ['AclBurstSize', 'EtypeValue']}
Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.
· Download HiSecOS-05200-EAGLE4003.zip — HiSecOS-05200-EAGLE4003/MIBs/HM2-FW-MIB.mib