The operational value of the edge port parameter. The object is initialized to the value of staPortAdminEdgePort and is set false when a BPDU is received.
Sources for this description
Hirschmann MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.248.13.7.4.1.5.2.1.5
The operational value of the edge port parameter. The object is initialized to the value of staPortAdminEdgePort and is set false when a BPDU is received.
Identification
{1 3 6 1 4 1 248 13 7 4 1 5 2 1 5}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
staPortOperEdgePort OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational value of the edge port parameter. The object is
initialized to the value of staPortAdminEdgePort and is set false
when a BPDU is received."
REFERENCE
"IEEE 802.1t clause 14.8.2, 18.3.4"
::= { staPortEntry 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The operational value of the edge port parameter. The object is initialized to the value of staPortAdminEdgePort and is set false when a BPDU is received.
Hirschmann MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: staPortOperEdgePort
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"staPortOperEdgePort",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The operational value of the edge port parameter. The object is initialized to the value of staPortAdminEdgePort and is set false when a BPDU is received.\"",
"REFERENCE",
"\"IEEE 802.1t clause 14.8.2, 18.3.4\"",
"::=",
"{",
"staPortEntry",
"5",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The operational value of the edge port parameter. The object is initialized to the value of staPortAdminEdgePort and is set false when a BPDU is received."
],
[
"REFERENCE",
"IEEE 802.1t clause 14.8.2, 18.3.4"
],
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Hirschmann support.
Module: Hirschmann-LION-24TP-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'RowPointer', 'MacAddress'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks', 'Gauge32'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'HMPRIV-MGMT-SNMP-MIB': ['hirschmann']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.248.13.7.4.1.5.2.1.2 | staPortFastForward | 0 | 0 | |
| 1.3.6.1.4.1.248.13.7.4.1.5.2.1.3 | staPortProtocolMigration | 0 | 0 | |
| 1.3.6.1.4.1.248.13.7.4.1.5.2.1.4 | staPortAdminEdgePort | 0 | 0 | |
| 1.3.6.1.4.1.248.13.7.4.1.5.2.1.6 | staPortAdminPointToPoint | 0 | 0 | |
| 1.3.6.1.4.1.248.13.7.4.1.5.2.1.7 | staPortOperPointToPoint | 0 | 0 | |
| 1.3.6.1.4.1.248.13.7.4.1.5.2.1.9 | staPortSystemStatus | 0 | 0 | |
| 1.3.6.1.4.1.248.13.7.4.1.5.2.1.10 | staPortLongAdminPathCost | 0 | 0 | |
| 1.3.6.1.4.1.248.13.7.4.1.5.2.1.11 | staPortLongOperPathCost | 0 | 0 |