OID reference

hmSysSTPErrorNumber

1.3.6.1.4.1.248.14.1.1.33

Description

Advertised the reason why (R)STP could not be switched on. Error reasons arte coded as OR operation bit by bit, see values: 0x00 - no errors - (R)STP is switched on, 0x01 - (R)STP cannot be switched on, because of standby mode, 0x02 - (R)STP cannot be switched on, because of kopp Local Active, 0x04 - (R)STP cannot be …

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.248.14.1.1 (hmSystemTable)
Node code
33
Node name
hmSysSTPErrorNumber
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.248.14.1.1.33
URN notation
urn:oid:1.3.6.1.4.1.248.14.1.1.33
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 248 14 1 1 33}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hirschmann(248) hmConfiguration(14) hmChassis(1) hmSystemTable(1) hmSysSTPErrorNumber(33)}
OID-IRI notation
  • /1/3/6/1/4/1/248/14/1/1/33
  • /ISO/Identified-Organization/6/1/4/1/248/14/1/1/33
  • /ISO/3/6/1/4/1/248/14/1/1/33
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/identified-organization/dod/internet/private/enterprises/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/identified-organization/dod/internet/private/vendor-objects/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/org/dod/internet/private/enterprise/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/org/dod/internet/private/enterprises/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/org/dod/internet/private/ldap-enterprise/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/org/dod/internet/private/vendor-objects/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/iso-identified-organization/dod/internet/private/enterprise/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/iso-organization/dod/internet/private/enterprise/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/iso-organization/dod/internet/private/enterprises/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber
  • /iso/iso-organization/dod/internet/private/vendor-objects/hirschmann/hmConfiguration/hmChassis/hmSystemTable/hmSysSTPErrorNumber

SNMP properties

Value type
Integer32
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
0–1000

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.248.14.1.1.33.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 3 distinct definitions; some records may not include a definition.

Show 3 published definitions

hmSysSTPErrorNumber · current

hmSysSTPErrorNumber	OBJECT-TYPE
			 SYNTAX 		 Integer32 (0..1000)
			 MAX-ACCESS 		 read-only
			 STATUS 		 current
			 DESCRIPTION
                 "Advertised the reason why (R)STP could not be switched on. 
				  Error reasons arte coded as OR operation bit by bit, see values:
				  0x00  - no errors - (R)STP is switched on,
                  0x01  - (R)STP cannot be switched on, because of standby mode,
                  0x02  - (R)STP cannot be switched on, because of kopp Local Active,
                  0x04  - (R)STP cannot be switched on, because of kopp Slave Active,
                  0x08  - (R)STP cannot be switched on, because of kopp Master Active,
                  0x10  - (R)STP cannot be switched on, because of sysRingOn and sysRMMode,
                  0x20  - (R)STP cannot be switched on, because of error if BB_SetParameter is occured.
                  "
			 ::= { hmSystemTable 33 }

hmSysSTPErrorNumber · current

hmSysSTPErrorNumber	OBJECT-TYPE
			 SYNTAX 		 Integer32 (0..1000)
			 MAX-ACCESS 		 read-only
			 STATUS 		 current
			 DESCRIPTION
                 "Advertised the reason why (R)STP could not be switched on. 
				  Error reasons are coded as OR operation bit by bit, see values:
				  0x00  - no errors - (R)STP is switched on,
                  0x01  - (R)STP cannot be switched on, because of standby mode,
                  0x02  - (R)STP cannot be switched on, because of kopp Local Active,
                  0x04  - (R)STP cannot be switched on, because of kopp Slave Active,
                  0x08  - (R)STP cannot be switched on, because of kopp Master Active,
                  0x10  - (R)STP cannot be switched on, because of sysRingOn and sysRMMode,
                  0x20  - (R)STP cannot be switched on, because of error if BB_SetParameter is occured.
                  "
			 ::= { hmSystemTable 33 }

hmSysSTPErrorNumber · current

hmSysSTPErrorNumber	OBJECT-TYPE
			 SYNTAX 		 Integer32 (0..1000)
			 MAX-ACCESS 		 read-only
			 STATUS 		 current
			 DESCRIPTION
                 "Advertised the reason why (R)STP could not be switched on. 
				  Error reasons are coded as OR operation bit by bit, see values:
				  0x00  - no errors - (R)STP is switched on,
                  0x01  - (R)STP cannot be switched on, because of standby mode,
                  0x02  - (R)STP cannot be switched on, because of kopp Local Active,
                  0x04  - (R)STP cannot be switched on, because of kopp Slave Active,
                  0x08  - (R)STP cannot be switched on, because of kopp Master Active,
                  0x10  - (R)STP cannot be switched on, because of sysRingOn and sysRMMode,
                  0x20  - (R)STP cannot be switched on, because of error if BB_SetParameter is occured.
                  "
			 ::= { hmSystemTable 33 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Advertised the reason why (R)STP could not be switched on. Error reasons arte coded as OR operation bit by bit, see values: 0x00 - no errors - (R)STP is switched on, 0x01 - (R)STP cannot be switched on, because of standby mode, 0x02 - (R)STP cannot be switched on, because of kopp Local Active, 0x04 - (R)STP cannot be switched on, because of kopp Slave Active, 0x08 - (R)STP cannot be switched on, because of kopp Master Active, 0x10 - (R)STP cannot be switched on, because of sysRingOn and sysRMMode, 0x20 - (R)STP cannot be switched on, because of error if BB_SetParameter is occured.

Sources for this description

Belden, GarrettCom and Hirschmann IT official standalone MIBs

See 1 matching source record

Description 2

Advertised the reason why (R)STP could not be switched on. Error reasons are coded as OR operation bit by bit, see values: 0x00 - no errors - (R)STP is switched on, 0x01 - (R)STP cannot be switched on, because of standby mode, 0x02 - (R)STP cannot be switched on, because of kopp Local Active, 0x04 - (R)STP cannot be switched on, because of kopp Slave Active, 0x08 - (R)STP cannot be switched on, because of kopp Master Active, 0x10 - (R)STP cannot be switched on, because of sysRingOn and sysRMMode, 0x20 - (R)STP cannot be switched on, because of error if BB_SetParameter is occured.

Sources for this description

Belden, GarrettCom and Hirschmann IT official standalone MIBsHirschmann MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Belden, GarrettCom and Hirschmann IT official standalone MIBs1 record · 1 source

Description 1

hmSysSTPErrorNumber · currentBelden, GarrettCom and Hirschmann IT official standalone MIBs1 source

Status in source: current.

Names: hmSysSTPErrorNumber

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "hmSysSTPErrorNumber",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1000",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Advertised the reason why (R)STP could not be switched on. Error reasons arte coded as OR operation bit by bit, see values: 0x00 - no errors - (R)STP is switched on, 0x01 - (R)STP cannot be switched on, because of standby mode, 0x02 - (R)STP cannot be switched on, because of kopp Local Active, 0x04 - (R)STP cannot be switched on, because of kopp Slave Active, 0x08 - (R)STP cannot be switched on, because of kopp Master Active, 0x10 - (R)STP cannot be switched on, because of sysRingOn and sysRMMode, 0x20 - (R)STP cannot be switched on, because of error if BB_SetParameter is occured. \"",
    "::=",
    "{",
    "hmSystemTable",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1000
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Advertised the reason why (R)STP could not be switched on. Error reasons arte coded as OR operation bit by bit, see values: 0x00 - no errors - (R)STP is switched on, 0x01 - (R)STP cannot be switched on, because of standby mode, 0x02 - (R)STP cannot be switched on, because of kopp Local Active, 0x04 - (R)STP cannot be switched on, because of kopp Slave Active, 0x08 - (R)STP cannot be switched on, because of kopp Master Active, 0x10 - (R)STP cannot be switched on, because of sysRingOn and sysRMMode, 0x20 - (R)STP cannot be switched on, because of error if BB_SetParameter is occured."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Belden, GarrettCom and Hirschmann IT official standalone MIBs, Hirschmann MIB copies (LibreNMS/Observium Community), and others1 record · 8 sources

Description 2

hmSysSTPErrorNumber · currentBelden, GarrettCom and Hirschmann IT official standalone MIBs, Hirschmann MIB copies (LibreNMS/Observium Community), and others8 sources

Status in source: current.

Names: hmSysSTPErrorNumber

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "hmSysSTPErrorNumber",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1000",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Advertised the reason why (R)STP could not be switched on. Error reasons are coded as OR operation bit by bit, see values: 0x00 - no errors - (R)STP is switched on, 0x01 - (R)STP cannot be switched on, because of standby mode, 0x02 - (R)STP cannot be switched on, because of kopp Local Active, 0x04 - (R)STP cannot be switched on, because of kopp Slave Active, 0x08 - (R)STP cannot be switched on, because of kopp Master Active, 0x10 - (R)STP cannot be switched on, because of sysRingOn and sysRMMode, 0x20 - (R)STP cannot be switched on, because of error if BB_SetParameter is occured. \"",
    "::=",
    "{",
    "hmSystemTable",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1000
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Advertised the reason why (R)STP could not be switched on. Error reasons are coded as OR operation bit by bit, see values: 0x00 - no errors - (R)STP is switched on, 0x01 - (R)STP cannot be switched on, because of standby mode, 0x02 - (R)STP cannot be switched on, because of kopp Local Active, 0x04 - (R)STP cannot be switched on, because of kopp Slave Active, 0x08 - (R)STP cannot be switched on, because of kopp Master Active, 0x10 - (R)STP cannot be switched on, because of sysRingOn and sysRMMode, 0x20 - (R)STP cannot be switched on, because of error if BB_SetParameter is occured."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.248)

Nisi Heinz

Siblings (43)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.248.14.1.1.1 hmSysProduct00
1.3.6.1.4.1.248.14.1.1.2 hmSysVersion00
1.3.6.1.4.1.248.14.1.1.3 hmSysGroupCapacity00
1.3.6.1.4.1.248.14.1.1.4 hmSysGroupMap00
1.3.6.1.4.1.248.14.1.1.5 hmSysMaxPowerSupply00
1.3.6.1.4.1.248.14.1.1.6 hmSysMaxFan00
1.3.6.1.4.1.248.14.1.1.7 hmSysGroupModuleCapacity00
1.3.6.1.4.1.248.14.1.1.8 hmSysModulePortCapacity00
1.3.6.1.4.1.248.14.1.1.9 hmSysGroupTable113
1.3.6.1.4.1.248.14.1.1.10 hmSysModuleTable111
1.3.6.1.4.1.248.14.1.1.11 hmInterfaceTable130
1.3.6.1.4.1.248.14.1.1.12 hmTrunkTable18
1.3.6.1.4.1.248.14.1.1.13 hmSFPTable129
1.3.6.1.4.1.248.14.1.1.19 hmSysBootVersion00
1.3.6.1.4.1.248.14.1.1.20 hmSysChassisName00
1.3.6.1.4.1.248.14.1.1.21 hmSysStpEnable00
1.3.6.1.4.1.248.14.1.1.22 hmSysFlowControl00
1.3.6.1.4.1.248.14.1.1.23 hmSysBOOTPEnable00
1.3.6.1.4.1.248.14.1.1.24 hmSysDHCPEnable00
1.3.6.1.4.1.248.14.1.1.25 hmSysTelnetEnable00
1.3.6.1.4.1.248.14.1.1.26 hmSysHTTPEnable00
1.3.6.1.4.1.248.14.1.1.27 hmSysPlugAndPlay00
1.3.6.1.4.1.248.14.1.1.29 hmBcastLimiterMode00
1.3.6.1.4.1.248.14.1.1.30 hmSystemTime00
1.3.6.1.4.1.248.14.1.1.31 hmSystemTimeSource00
1.3.6.1.4.1.248.14.1.1.32 hmSysStpBPDUGuardEnable00
1.3.6.1.4.1.248.14.1.1.34 hmSysSoftwareCapability00
1.3.6.1.4.1.248.14.1.1.35 hmLEDGroup424
1.3.6.1.4.1.248.14.1.1.36 hmDIPSwitchGroup410
1.3.6.1.4.1.248.14.1.1.37 hmSysMaxTrunks00
1.3.6.1.4.1.248.14.1.1.38 hmLimiterGroup29
1.3.6.1.4.1.248.14.1.1.39 hmSysUSBGroup11
1.3.6.1.4.1.248.14.1.1.40 hmSysSwitchGroup1220
1.3.6.1.4.1.248.14.1.1.41 hmSysSelftestGroup55
1.3.6.1.4.1.248.14.1.1.42 hmSysOEMGroup11
1.3.6.1.4.1.248.14.1.1.43 hmSysMaxSignalContacts00
1.3.6.1.4.1.248.14.1.1.44 hmSysHttpsEnable00
1.3.6.1.4.1.248.14.1.1.45 hmSysHttpsPortNumber00
1.3.6.1.4.1.248.14.1.1.46 hmSysSkipAcaOnBoot00
1.3.6.1.4.1.248.14.1.1.47 hmSysConsoleServiceShellAdminState00
1.3.6.1.4.1.248.14.1.1.48 hmSysHttpsCertFingerPrintType00
1.3.6.1.4.1.248.14.1.1.49 hmSysHttpsCertFingerPrint00
1.3.6.1.4.1.248.14.1.1.100 hmInterfaceExtTable12