OID reference

physicalPortDefCdPostCompensationRange

1.3.6.1.4.1.2544.1.11.10.3.4.1.1.126

Description

CD Post Compensation Range Range 1: [-22 ns/nm to +6 ns/nm] or [-20 ns/nm to +2 ns/nm] Range 2: [-72 ns/nm to +6 ns/nm] or [-45 ns/nm to +5 ns/nm] Range 3: [-120 ns/nm to +6 ns/nm] Range 4: [-280 ns/nm to +6 ns/nm]

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.2544.1.11.10.3.4.1.1 (physicalPortDefEntry)
Node code
126
Node name
physicalPortDefCdPostCompensationRange
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.126
URN notation
urn:oid:1.3.6.1.4.1.2544.1.11.10.3.4.1.1.126
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 2544 1 11 10 3 4 1 1 126}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) adva(2544) advaProducts(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) adva(2544) products(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) advaMIB(2544) advaProducts(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) advaMIB(2544) products(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) adva(2544) advaProducts(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) adva(2544) products(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) advaMIB(2544) advaProducts(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) advaMIB(2544) products(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) adva(2544) advaProducts(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) adva(2544) products(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) advaMIB(2544) advaProducts(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) advaMIB(2544) products(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) adva(2544) advaProducts(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) adva(2544) products(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) advaMIB(2544) advaProducts(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) advaMIB(2544) products(1) fspR7(11) advaFspR7Def(10) managementDef(3) facilityMgmtDef(4) physicalPortDefTable(1) physicalPortDefEntry(1) physicalPortDefCdPostCompensationRange(126)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/2544/1/11/10/3/4/1/1/126
  • /ISO/Identified-Organization/6/1/4/1/2544/1/11/10/3/4/1/1/126
  • /ISO/3/6/1/4/1/2544/1/11/10/3/4/1/1/126
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/adva/advaProducts/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/enterprise/adva/products/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/enterprise/advaMIB/advaProducts/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/enterprise/advaMIB/products/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/enterprises/adva/advaProducts/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/enterprises/adva/products/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/enterprises/advaMIB/advaProducts/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/enterprises/advaMIB/products/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/adva/advaProducts/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/adva/products/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/advaMIB/advaProducts/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/advaMIB/products/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/vendor-objects/adva/advaProducts/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/vendor-objects/adva/products/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/vendor-objects/advaMIB/advaProducts/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • /iso/identified-organization/dod/internet/private/vendor-objects/advaMIB/products/fspR7/advaFspR7Def/managementDef/facilityMgmtDef/physicalPortDefTable/physicalPortDefEntry/physicalPortDefCdPostCompensationRange
  • Additional combinations skipped.

SNMP properties

Value type
FspR7CdPostCompensationRange
Maximum access defined by MIB
read-only
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

physicalPortDefCdPostCompensationRange OBJECT-TYPE
    SYNTAX        FspR7CdPostCompensationRange
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION   "CD Post Compensation Range
        Range 1: [-22 ns/nm   to +6 ns/nm] or [-20 ns/nm to +2 ns/nm]
        Range 2: [-72 ns/nm   to +6 ns/nm] or [-45 ns/nm to +5 ns/nm]
        Range 3: [-120 ns/nm to +6 ns/nm]
        Range 4: [-280 ns/nm to +6 ns/nm]"
    ::= { physicalPortDefEntry 126 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

CD Post Compensation Range Range 1: [-22 ns/nm to +6 ns/nm] or [-20 ns/nm to +2 ns/nm] Range 2: [-72 ns/nm to +6 ns/nm] or [-45 ns/nm to +5 ns/nm] Range 3: [-120 ns/nm to +6 ns/nm] Range 4: [-280 ns/nm to +6 ns/nm]

Sources for this description

ADVA MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1ADVA MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

physicalPortDefCdPostCompensationRange · currentADVA MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: physicalPortDefCdPostCompensationRange

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "physicalPortDefCdPostCompensationRange",
    "OBJECT-TYPE",
    "SYNTAX",
    "FspR7CdPostCompensationRange",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"CD Post Compensation Range Range 1: [-22 ns/nm to +6 ns/nm] or [-20 ns/nm to +2 ns/nm] Range 2: [-72 ns/nm to +6 ns/nm] or [-45 ns/nm to +5 ns/nm] Range 3: [-120 ns/nm to +6 ns/nm] Range 4: [-280 ns/nm to +6 ns/nm]\"",
    "::=",
    "{",
    "physicalPortDefEntry",
    "126",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "FspR7CdPostCompensationRange"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "CD Post Compensation Range Range 1: [-22 ns/nm to +6 ns/nm] or [-20 ns/nm to +2 ns/nm] Range 2: [-72 ns/nm to +6 ns/nm] or [-45 ns/nm to +5 ns/nm] Range 3: [-120 ns/nm to +6 ns/nm] Range 4: [-280 ns/nm to +6 ns/nm]"
    ],
    null,
    null,
    null,
    null
  ]
}
  • ADVA MIB copies (LibreNMS/Observium Community) · Publisher's source file: ADVA-FSPR7-DEF-MIB

    Vendor MIB copy from the LibreNMS archive. ADVA support.

    Module: ADVA-FSPR7-DEF-MIB

    See published definition above

    Module imports
    {'ADVA-MIB': ['fspR7', 'ApsHoldoffTime', 'ApsDirection', 'EnableState', 'EthDuplexMode', 'FspR7EquipmentType', 'LoopConfig', 'OhTerminationLevel', 'OtnPayloadType', 'OtnTcmLevel', 'ProtectionMech', 'SonetTimingSource', 'SonetTraceForm', 'TimMode', 'VirtualContainerType'], 'SNMPv2-TC': ['RowStatus'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Unsigned32', 'Integer32', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'ADVA-FSPR7-MIB': ['entityConnectionClassName', 'entityContainerShelfNo', 'entityContainerSlotNo', 'entityContainerPortNo', 'entityContainerExtNo', 'entityContainerClassName', 'entityCrossConnFromShelfNo', 'entityCrossConnFromSlotNo', 'entityCrossConnFromPortNo', 'entityCrossConnFromExtNo', 'entityCrossConnFromClassName', 'entityCrossConnToShelfNo', 'entityCrossConnToSlotNo', 'entityCrossConnToPortNo', 'entityCrossConnToExtNo', 'entityCrossConnToClassName', 'entityCrossConnClassName', 'entityCrsOptLineFromIndexNo1', 'entityCrsOptLineFromIndexNo2', 'entityCrsOptLineFromIndexNo3', 'entityCrsOptLineFromIndexNo4', 'entityCrsOptLineFromClassName', 'entityCrsOptLineToIndexNo1', 'entityCrsOptLineToIndexNo2', 'entityCrsOptLineToIndexNo3', 'entityCrsOptLineToIndexNo4', 'entityCrsOptLineToClassName', 'entityCrsOptLineClassName', 'entityDcnShelfNo', 'entityDcnSlotNo', 'entityDcnPortNo', 'entityDcnExtNo', 'entityDcnClassName', 'entityEqptShelfNo', 'entityEqptSlotNo', 'entityEqptPortNo', 'entityEqptExtNo', 'entityEqptClassName', 'entityExternalPortShelfNo', 'entityExternalPortSlotNo', 'entityExternalPortPortNo', 'entityExternalPortExtNo', 'entityExternalPortClassName', 'entityFacilityShelfNo', 'entityFacilitySlotNo', 'entityFacilityPortNo', 'entityFacilityExtNo', 'entityFacilityClassName', 'entityOpticalMuxShelfNo', 'entityOpticalMuxSlotNo', 'entityOpticalMuxPortNo', 'entityOpticalMuxExtNo', 'entityOpticalMuxClassName', 'entityOptLineIndexNo1', 'entityOptLineClassName', 'entityShelfConnShelfNo', 'entityShelfConnSlotNo', 'entityShelfConnPortNo', 'entityShelfConnExtNo', 'entityShelfConnClassName', 'entityTerminPointIndexNo1', 'entityTerminPointIndexNo2', 'entityTerminPointIndexNo3', 'entityTerminPointIndexNo4', 'entityTerminPointClassName', 'entityFfpShelfNo', 'entityFfpSlotNo', 'entityFfpPortNo', 'entityFfpExtNo', 'entityFfpClassName', 'entityCrossDcnShelfNo', 'entityCrossDcnSlotNo', 'entityCrossDcnPortNo', 'entityCrossDcnExtNo', 'entityCrossDcnClassName'], 'ADVA-FSPR7-TC-MIB': ['ApsRevertMode', 'ApsType', 'CryptoFspR7EncryptionCommunication', 'FfpType', 'FspR7Acp', 'FspR7APSCommand', 'FspR7ApsFarEndModule', 'FspR7AdminState', 'FspR7AlsMode', 'FspR7BERThreshold', 'FspR7BidirectionalChannel', 'FspR7Baund', 'FspR7Bitrate', 'FspR7CapInventory', 'FspR7CdCompensationRange', 'FspR7CdPostCompensationRange', 'FspR7ChannelBandwidth', 'FspR7ChannelIdentifier', 'FspR7ChannelRangeInventory', 'FspR7ChannelSpacing', 'FspR7CodeGain', 'FspR7Conn', 'FspR7ConnectorType', 'FspR7CpAuthType', 'FspR7DCFiberType', 'FspR7DeploymentScenario', 'FspR7DhcpServer', 'FspR7DisableEnable', 'FspR7DispersionCompensation', 'FspR7DispersionModes', 'FspR7DmsrmtOperation', 'FspR7EdfaOutputPowerRating', 'FspR7EnableDisable', 'FspR7ErrorFwdMode', 'FspR7FecType', 'FspR7FiberBrand', 'FspR7FlowControlMode', 'FspR7FrameFormat', 'FspR7FunctionCrs', 'FspR7Gain', 'FspR7GainRange', 'FspR7GccUsage', 'FspR7InterfaceCrossover', 'FspR7InterfaceType', 'FspR7InvertTelemetryInputLogic', 'FspR7IpType', 'FspR7IPv6Type', 'FspR7IpMode', 'FspR7LacpMode', 'FspR7LacpTimeout', 'FspR7LagPortType', 'FspR7LaneGroupInventory', 'FspR7LaserDelayTimer', 'FspR7Length', 'FspR7LineCoding', 'FspR7LLDPNeighbors', 'FspR7LLDPScope', 'FspR7ManualAuto', 'FspR7Mapping', 'FspR7MaxBitErrorRate', 'FspR7MonLevel', 'FspR7MuxMethod', 'FspR7NoYes', 'FspR7NumberOfChannels', 'FspR7OpticalBand', 'FspR7OpticalFiberType', 'FspR7OpticalGroup', 'FspR7OpticalInterfaceReach', 'FspR7OpticalSubBand', 'FspR7Optimize', 'FspR7OpuPayloadType', 'FspR7OscUsage', 'FspR7OspfMode', 'FspR7OtdrPeriod', 'FspR7PathNode', 'FspR7PlugDataRate', 'FspR7PlugType', 'FspR7PlugMode', 'FspR7PmReset', 'FspR7PortBehaviour', 'FspR7PortMode', 'FspR7PortRole', 'FspR7ProtectionType', 'FspR7PsuOutputPower', 'FspR7RlsAction', 'FspR7RoadmNumber', 'FspR7RowStatus', 'FspR7SingleFiberLocation', 'FspR7SnmpHexString', 'FspR7SnmpLongString', 'FspR7SupplyType', 'FspR7TelemetryOutput', 'FspR7TerminationMode', 'FspR7TiltSet', 'FspR7TimDetMode', 'FspR7Topology', 'FspR7TrafficDirection', 'FspR7TransmissionMode', 'FspR7TxOffOnTm', 'FspR7TypeConnection', 'FspR7TypeCrs', 'FspR7Unsigned32Caps', 'FspR7UntaggedFrames', 'FspR7VoaMode', 'FspR7XfpDecisionThres', 'FspR7YesNo'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download ADVA-FSPR7-DEF-MIB

    Related source files and packages:

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.2544)

Gerald Vollnhals &

Siblings (142)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.51 physicalPortDefSigDegThresOduTcmB00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.52 physicalPortDefSigDegThresOduTcmC00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.53 physicalPortDefSignalDegradePeriod00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.54 physicalPortDefSigDegPeriodOdu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.55 physicalPortDefSigDegPeriodOtu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.56 physicalPortDefSigDegPeriodIntegration00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.57 physicalPortDefSigDegPeriodSdhSection00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.58 physicalPortDefSigDegPeriodOduTcmA00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.59 physicalPortDefSigDegPeriodOduTcmB00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.60 physicalPortDefSigDegPeriodOduTcmC00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.61 physicalPortDefOtnStuffing00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.62 physicalPortDefTcmALevel00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.63 physicalPortDefTcmBLevel00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.64 physicalPortDefTcmCLevel00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.65 physicalPortDefTerminationLevel00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.66 physicalPortDefTimingSource00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.67 physicalPortDefTimModeOdu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.68 physicalPortDefTimModeOtu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.69 physicalPortDefTimModeSonetSection00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.70 physicalPortDefTimModeOduTcmA00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.71 physicalPortDefTimModeOduTcmB00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.72 physicalPortDefTimModeOduTcmC00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.73 physicalPortDefTraceFormSonetSection00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.74 physicalPortDefTraceExpectedSonetSection00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.75 physicalPortDefTraceTransmitSonetSection00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.76 physicalPortDefTraceExpectedOtu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.77 physicalPortDefTraceTransmitSapiOtu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.78 physicalPortDefTraceTransmitDapiOtu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.79 physicalPortDefTraceTransmitOpspOtu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.80 physicalPortDefTraceExpectedOdu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.81 physicalPortDefTraceTransmitSapiOdu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.82 physicalPortDefTraceTransmitDapiOdu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.83 physicalPortDefTraceTransmitOpspOdu00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.84 physicalPortDefTraceExpectedOduTcmA00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.85 physicalPortDefTraceTransmitSapiOduTcmA00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.86 physicalPortDefTraceTransmitDapiOduTcmA00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.87 physicalPortDefTraceTransmitOpspOduTcmA00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.88 physicalPortDefTraceExpectedOduTcmB00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.89 physicalPortDefTraceTransmitSapiOduTcmB00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.90 physicalPortDefTraceTransmitDapiOduTcmB00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.91 physicalPortDefTraceTransmitOpspOduTcmB00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.92 physicalPortDefTraceExpectedOduTcmC00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.93 physicalPortDefTraceTransmitSapiOduTcmC00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.94 physicalPortDefTraceTransmitDapiOduTcmC00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.95 physicalPortDefTraceTransmitOpspOduTcmC00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.96 physicalPortDefTurnupConfig00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.97 physicalPortDefTxOffDelay00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.98 physicalPortDefVoaMode00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.99 physicalPortDefVoaSetpoint00
1.3.6.1.4.1.2544.1.11.10.3.4.1.1.100 physicalPortDefLagPrio00