OSC Optical Output Power Transmitted
Sources for this description
ADVA MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2544.1.11.2.6.2.158.1.2
OSC Optical Output Power Transmitted
Identification
{1 3 6 1 4 1 2544 1 11 2 6 2 158 1 2}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: entityIndex, intervalPhysPerfOscOpticalOutputPwr15minNumber.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.2544.1.11.2.6.2.158.1.2
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
intervalPhysPerfOscOpticalOutputPwr15minLow OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OSC Optical Output Power Transmitted"
::= { intervalPhysPerfOscOpticalOutputPwr15minEntry 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
OSC Optical Output Power Transmitted
ADVA MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: intervalPhysPerfOscOpticalOutputPwr15minLow
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"intervalPhysPerfOscOpticalOutputPwr15minLow",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"UNITS",
[
"literal",
"22302e312064426d22"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"OSC Optical Output Power Transmitted\"",
"::=",
"{",
"intervalPhysPerfOscOpticalOutputPwr15minEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
[
"UNITS",
"0.1 dBm"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"OSC Optical Output Power Transmitted"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. ADVA support.
Module: FspR7-MIB
See published definition above
{'ADVA-MIB': ['fspR7', 'TrapAlarmSeverity', 'ServiceImpairment', 'neEventLogTimeStamp', 'neEventLogIdentityTranslation', 'config', 'EnableState', 'OnOff', 'neTrapsinkAddress', 'Counter64String', 'EnableStateCaps', 'entityIndex', 'entityClass', 'entityContainedIn', 'controlPlaneWdmEntityIndex', 'controlPlaneEthEntityIndex', 'controlPlaneOtnEntityIndex', 'ptpEntityIndex', 'ptpEntityClass', 'ptpEntityContainedIn', 'LoopConfig', 'EthDuplexMode', 'EthDuplexModeCaps', 'SonetTimingSource', 'EntityIndex', 'VirtualContainerType', 'SonetVcBundleAllocation', 'SonetVcBundleAllocationCaps', 'ProtectionMech', 'ProtectionMechCaps', 'OtnPayloadType', 'OtnPayloadTypeCaps', 'VirtualContainerTypeCaps', 'OhTerminationLevel', 'OhTerminationLevelCaps', 'Grade', 'ApsHoldoffTime', 'OtnTcmLevel', 'SonetTimingSourceCaps', 'OtnTcmLevelCaps', 'ApsHoldoffTimeCaps', 'LoopConfigCaps', 'SonetTraceForm', 'TimMode', 'SonetTraceFormCaps', 'TimModeCaps', 'LogicalIfTransportCaps', 'snmpProxyEntrySingleTargetOutNodeAgentStatus', 'snmpProxyServerSynchroStage', 'vtpEntityIndex'], 'SNMPv2-TC': ['DisplayString', 'TestAndIncr', 'TimeStamp', 'RowStatus', 'DateAndTime', 'TruthValue', 'TEXTUAL-CONVENTION', 'MacAddress'], 'ENTITY-MIB': ['entPhysicalIndex'], 'SNMPv2-SMI': ['Counter32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'TimeTicks', 'mib-2', 'snmpModules', 'enterprises', 'Unsigned32', 'Integer32', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2544.1.11.2.6.2.158.1.1 | intervalPhysPerfOscOpticalOutputPwr15minNumber | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.11.2.6.2.158.1.3 | intervalPhysPerfOscOpticalOutputPwr15minMean | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.11.2.6.2.158.1.4 | intervalPhysPerfOscOpticalOutputPwr15minHigh | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.11.2.6.2.158.1.5 | intervalPhysPerfOscOpticalOutputPwr15minValidFlag | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.11.2.6.2.158.1.6 | intervalPhysPerfOscOpticalOutputPwr15minTimeStamp | 0 | 0 |