This object must be used to specify the type of the Master Clock Interface.
Sources for this description
ADVA MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2544.1.12.18.1.13.1.8
This object must be used to specify the type of the Master Clock Interface.
Identification
{1 3 6 1 4 1 2544 1 12 18 1 13 1 8}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
f3PtpMCIClockType OBJECT-TYPE
SYNTAX MasterClockType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object must be used to specify the type of the Master Clock Interface."
::= { f3PtpMCIEntry 8 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This object must be used to specify the type of the Master Clock Interface.
ADVA MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: f3PtpMCIClockType
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"f3PtpMCIClockType",
"OBJECT-TYPE",
"SYNTAX",
"MasterClockType",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"This object must be used to specify the type of the Master Clock Interface.\"",
"::=",
"{",
"f3PtpMCIEntry",
"8",
"}"
],
"syntax_tree": [
[
"row",
"MasterClockType"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object must be used to specify the type of the Master Clock Interface."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. ADVA support.
Module: F3-PTP-MIB
See published definition above
{'IPV6-TC': ['Ipv6Address'], 'ADVA-MIB': ['fsp150cm'], 'SNMPv2-TC': ['DisplayString', 'TruthValue', 'RowStatus', 'StorageType', 'VariablePointer', 'MacAddress', 'DateAndTime', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'IpAddress', 'Integer32', 'Unsigned32', 'Counter64'], 'F3-SYNC-MIB': ['SSMQualityLevel', 'HoldoverAccuracy', 'TimeSource'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'CM-COMMON-MIB': ['IpVersion', 'CmPmIntervalType', 'CmPmBinAction', 'F3DisplayString', 'AdminState', 'OperationalState', 'SecondaryState', 'PerfCounter64', 'IpPriorityMapMode', 'FlowSecState', 'AdminState', 'OperationalState', 'SecondaryState', 'PerfCounter64', 'IpPriorityMapMode'], 'CM-ENTITY-MIB': ['neIndex', 'shelfIndex', 'slotIndex'], 'CM-FACILITY-MIB': ['cmEthernetAccPortIndex', 'cmEthernetNetPortIndex', 'cmEthernetAccPortEntry', 'cmEthernetNetPortEntry', 'cmEthernetTrafficPortIndex', 'cmEthernetTrafficPortEntry'], 'CM-REDUNDANCY-MIB': ['CmGenPgSwitchoverReason']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. ADVA support.
Module: F3-PTP-MIB
{'ADVA-MIB': ['fsp150cm'], 'SNMPv2-TC': ['DisplayString', 'TruthValue', 'RowStatus', 'StorageType', 'VariablePointer', 'MacAddress', 'DateAndTime', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'IpAddress', 'Integer32', 'Unsigned32', 'Counter64'], 'F3-SYNC-MIB': ['SSMQualityLevel', 'HoldoverAccuracy', 'TimeSource'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'CM-COMMON-MIB': ['IpVersion', 'CmPmIntervalType', 'CmPmBinAction', 'F3DisplayString', 'AdminState', 'OperationalState', 'SecondaryState', 'PerfCounter64', 'IpPriorityMapMode'], 'CM-ENTITY-MIB': ['neIndex', 'shelfIndex', 'slotIndex'], 'CM-FACILITY-MIB': ['cmEthernetAccPortIndex', 'cmEthernetNetPortIndex', 'cmEthernetAccPortEntry', 'cmEthernetNetPortEntry']}Related source files and packages:
Registration