Pointer to a Flow instance which is protected by an ERP instance. The pointer must be set to cmFlowIndex or cmMPFlowIndex instance.
Sources for this description
ADVA MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2544.1.12.25.1.2.1.1
Pointer to a Flow instance which is protected by an ERP instance. The pointer must be set to cmFlowIndex or cmMPFlowIndex instance.
Identification
{1 3 6 1 4 1 2544 1 12 25 1 2 1 1}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
f3ErpGroupProtectedFlow OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pointer to a Flow instance which is protected by an ERP instance.
The pointer must be set to cmFlowIndex or cmMPFlowIndex instance."
::= { f3ErpGroupProtectedFlowEntry 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Pointer to a Flow instance which is protected by an ERP instance. The pointer must be set to cmFlowIndex or cmMPFlowIndex instance.
ADVA MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: f3ErpGroupProtectedFlow
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"f3ErpGroupProtectedFlow",
"OBJECT-TYPE",
"SYNTAX",
"VariablePointer",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Pointer to a Flow instance which is protected by an ERP instance. The pointer must be set to cmFlowIndex or cmMPFlowIndex instance.\"",
"::=",
"{",
"f3ErpGroupProtectedFlowEntry",
"1",
"}"
],
"syntax_tree": [
[
"row",
"VariablePointer"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Pointer to a Flow instance which is protected by an ERP instance. The pointer must be set to cmFlowIndex or cmMPFlowIndex instance."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. ADVA support.
Module: F3-ERP-MIB
See published definition above
{'ADVA-MIB': ['fsp150cm'], 'SNMPv2-TC': ['TruthValue', 'RowStatus', 'StorageType', 'DisplayString', 'MacAddress', 'VariablePointer', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CM-COMMON-MIB': ['AdminState', 'OperationalState', 'SecondaryState', 'VlanId', 'VlanPriority', 'VlanEthertype'], 'CM-ENTITY-MIB': ['neIndex'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMDLevel'], 'CM-PROTECTION-MIB': ['CmProtUnitType', 'CmProtUnitState']}Related source files and packages:
Same file in Observium Community.
Registration