The association number (AN) for identifying a transmitting SA.
Sources for this description
ADVA MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2544.1.12.36.1.6.1.1
The association number (AN) for identifying a transmitting SA.
Identification
{1 3 6 1 4 1 2544 1 12 36 1 6 1 1}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex, f3ConnectGuardRxSAIndex.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
f3ConnectGuardRxSAIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The association number (AN) for identifying a transmitting
SA."
REFERENCE
"IEEE 802.1AE Clause 10.7.21"
::= { f3ConnectGuardRxSAEntry 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The association number (AN) for identifying a transmitting SA.
ADVA MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: f3ConnectGuardRxSAIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"f3ConnectGuardRxSAIndex",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"The association number (AN) for identifying a transmitting SA.\"",
"REFERENCE",
"\"IEEE 802.1AE Clause 10.7.21\"",
"::=",
"{",
"f3ConnectGuardRxSAEntry",
"1",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The association number (AN) for identifying a transmitting SA."
],
[
"REFERENCE",
"IEEE 802.1AE Clause 10.7.21"
],
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. ADVA support.
Module: F3-CONNECTGUARD-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IPV6-TC': ['Ipv6Address'], 'ADVA-MIB': ['fsp150cm'], 'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'TruthValue', 'RowStatus', 'StorageType', 'MacAddress', 'VariablePointer', 'TEXTUAL-CONVENTION', 'TimeStamp'], 'ENTITY-MIB': ['PhysicalIndex'], 'F3-FPM-MIB': ['f3AccFlowPointEntry', 'f3NetFlowPointEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'IpAddress'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CM-COMMON-MIB': ['AdminState', 'OperationalState', 'SecondaryState', 'EthernetMediaType', 'EthernetPortSpeed', 'TrafficDirection', 'SfpConnectorValue', 'SfpMediaType', 'VlanId', 'VlanPriority', 'VlanTagType', 'PriorityMapMode', 'PerfCounter64', 'AfpTagControl', 'VlanEthertype', 'CmPmIntervalType', 'CmPmBinAction', 'F3DisplayString'], 'CM-ENTITY-MIB': ['neIndex', 'shelfIndex', 'slotIndex', 'f3UsbHostIndex', 'networkElementEntry'], 'CM-FACILITY-MIB': ['cmFlowEntry'], 'IEEE8021-SECY-MIB': ['SecySCI']}Related source files and packages:
Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2544.1.12.36.1.6.1.2 | f3ConnectGuardRxSAState | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.36.1.6.1.3 | f3ConnectGuardRxSANextPN | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.36.1.6.1.4 | f3ConnectGuardRxSASAKUnchanged | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.36.1.6.1.5 | f3ConnectGuardRxSACreatedTime | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.36.1.6.1.6 | f3ConnectGuardRxSAStartedTime | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.36.1.6.1.7 | f3ConnectGuardRxSAStoppedTime | 0 | 0 |