MAC Table Entry will be removed from the forwarding table after an inactivity time represented by this entry. Not used in EG-X.
Sources for this description
ADVA MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2544.1.12.4.1.60.1.7
MAC Table Entry will be removed from the forwarding table after an inactivity time represented by this entry. Not used in EG-X.
Identification
{1 3 6 1 4 1 2544 1 12 4 1 60 1 7}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: neIndex, cmMPFlowIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.2544.1.12.4.1.60.1.7
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
cmMPFlowAgingTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MAC Table Entry will be removed from the forwarding table
after an inactivity time represented by this entry.
Not used in EG-X."
::= { cmMPFlowEntry 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
MAC Table Entry will be removed from the forwarding table after an inactivity time represented by this entry. Not used in EG-X.
ADVA MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: cmMPFlowAgingTimer
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cmMPFlowAgingTimer",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"MAC Table Entry will be removed from the forwarding table after an inactivity time represented by this entry. Not used in EG-X.\"",
"::=",
"{",
"cmMPFlowEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"MAC Table Entry will be removed from the forwarding table after an inactivity time represented by this entry. Not used in EG-X."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. ADVA support.
Module: CM-FACILITY-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'IPV6-TC': ['Ipv6Address'], 'ADVA-MIB': ['fsp150cm'], 'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'TruthValue', 'RowStatus', 'StorageType', 'MacAddress', 'VariablePointer', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex'], 'F3-LAG-MIB': ['f3LagIndex'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'IpAddress', 'Counter64'], 'F3-SYNC-MIB': ['SSMQualityLevel', 'SquelchControl', 'TimeSource', 'ClkSignalType'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CM-COMMON-MIB': ['AdminState', 'OperationalState', 'SecondaryState', 'EthernetMediaType', 'EthernetPortSpeed', 'TrafficDirection', 'SfpConnectorValue', 'SfpMediaType', 'VlanId', 'VlanPriority', 'VlanTagType', 'PriorityMapMode', 'SignalDirectionType', 'AfpTagControl', 'VlanEthertype', 'CmTrafficAclFilterActionType', 'IpVersion', 'CmTrafficACLPriorityType', 'CmTrafficAclFilterType', 'CmTrafficAclProtocolType', 'TDMFrequencySourceType', 'F3DisplayString', 'FlowSecState', 'UsbOperationalMode', 'SfpIdentifierValue'], 'CM-ENTITY-MIB': ['neIndex', 'shelfIndex', 'slotIndex', 'f3UsbHostIndex', 'networkElementEntry']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. ADVA support.
Module: CM-FACILITY-MIB
{'IF-MIB': ['InterfaceIndex'], 'IPV6-TC': ['Ipv6Address'], 'ADVA-MIB': ['fsp150cm'], 'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'TruthValue', 'RowStatus', 'StorageType', 'MacAddress', 'VariablePointer', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex'], 'F3-LAG-MIB': ['f3LagIndex'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'IpAddress', 'Counter64'], 'F3-SYNC-MIB': ['SSMQualityLevel', 'SquelchControl', 'TimeSource'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'CM-COMMON-MIB': ['AdminState', 'OperationalState', 'SecondaryState', 'EthernetMediaType', 'EthernetPortSpeed', 'TrafficDirection', 'SfpConnectorValue', 'SfpMediaType', 'VlanId', 'VlanPriority', 'VlanTagType', 'PriorityMapMode', 'SignalDirectionType', 'AfpTagControl', 'VlanEthertype', 'CmTrafficAclFilterActionType', 'IpVersion', 'CmTrafficACLPriorityType', 'CmTrafficAclFilterType', 'CmTrafficAclProtocolType', 'TDMFrequencySourceType', 'F3DisplayString', 'FlowSecState'], 'CM-ENTITY-MIB': ['neIndex', 'shelfIndex', 'slotIndex', 'f3UsbHostIndex', 'networkElementEntry']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.1 | cmMPFlowIndex | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.2 | cmMPFlowCircuitName | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.3 | cmMPFlowAdminState | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.4 | cmMPFlowOperationalState | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.5 | cmMPFlowSecondaryState | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.6 | cmMPFlowLearningEnabled | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.8 | cmMPFlowFwdTableSizeProfileID | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.9 | cmMPFlowtableFullAction | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.10 | cmMPFlowStorageType | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.11 | cmMPFlowRowStatus | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.12 | cmMPFlowLearningConfigAction | 0 | 0 | |
| 1.3.6.1.4.1.2544.1.12.4.1.60.1.13 | cmMPFlowFPList | 0 | 0 |