Description 1
Camera connection status (0: No connection, 1: Connection)
Sources for this description
Panasonic / i-PRO official SNMP device manuals
OID reference
1.3.6.1.4.1.258.5100.200.1.15.1
Camera connection status (0: No connection, 1: Connection)
Identification
{1 3 6 1 4 1 258 5100 200 1 15 1}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Camera connection status (0: No connection, 1: Connection)
Panasonic / i-PRO official SNMP device manuals
Description 2
0: connect 1: Not connect
Panasonic official WJ-NV200 MIB specification
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: unspecified.
Names: camSyncState001
{
"syntax": "INTEGER"
}Module: PANA-REC-MIB
Source data warning: Historical Panasonic namespace from a 2020 device manual; this documents published device definitions, not an independent confirmation of registration or support on current i-PRO devices.
Source data warning: Only this explicitly named appendix endpoint is materialized from the wildcard table. Ellipses and run-time SNMP instance indexes are not expanded.
objectName camSyncStatemmm (mmm is camera No.) object id .1.3.6.1.4.1.258.5100.200.1.15.* (* is camera No.) SYNTAX RANGE INTEGER DESCRIPTION Camera connection status (0: No connection, 1: Connection)
+ panasonic(258) | + securityProducts(5100) | | + recorder(200) | | | + recInfo(1) | | | | + camSyncState(15) | | | | | + camSyncState001(1)
Status in source: unspecified.
Names: CamSvncState
{
"access": "read-only"
}Source data warning: This historical WJ-NV200 device manual explicitly lists this numeric address and description. It documents a device-specific SNMP reference, not independent proof of an ASN.1 registration or compatibility with other devices. The source also describes indexed address ranges; those ranges are not expanded into registrations.
Source data warning: The 2012 WJ-NV200 table says 0 means connected and 1 means not connected, while the 2020 i-PRO recorder manual states the opposite for the same numeric branch. The documents cover different device editions; verify the actual model and firmware. This is an explicitly printed endpoint of an indexed range, not proof of an independently registered object.
Usage: Index 1-16 is Camera channel.
HdrCategory.1.15.1 -- HdrCategory.1.15.64 0: connect 1: Not connect
Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.258.5100.200.1.15.64 | CamSvncState | 0 | 0 | |
| 1.3.6.1.4.1.258.5100.200.1.15.128 | camSyncState128 | 0 | 0 |