syncEPortSSMPriority — Edgecore official enterprise switch MIBs, Edgecore MIB copies (Observium Community)
SyncE SSM Priority which is used to do clock souce selection. It only can be configured when SSM status is enabled
{1 3 6 1 4 1 259 10 1 11 1 72 9 1 4}
SyncE SSM Priority which is used to do clock souce selection. It only can be configured when SSM status is enabled
Status in source: current.
Names: syncEPortSSMPriority
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"syncEPortSSMPriority",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"2",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"SyncE SSM Priority which is used to do clock souce selection. It only can be configured when SSM status is enabled\"",
"::=",
"{",
"syncEPortEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"SyncE SSM Priority which is used to do clock souce selection. It only can be configured when SSM status is enabled"
],
null,
null,
null,
null
]
}Module: Ecs4810-12m-MIB
syncEPortSSMPriority OBJECT-TYPE
SYNTAX Integer32 (0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SyncE SSM Priority which is used to do clock souce selection.
It only can be configured when SSM status is enabled"
::= { syncEPortEntry 4 }{'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength']}Downloaded: 2026-10-23T18:27:46.074600+00:00.
Vendor MIB copy from the Observium Community archive. Edgecore support.
Module: ECS4810-12M-MIB
syncEPortSSMPriority OBJECT-TYPE
SYNTAX Integer32 (0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SyncE SSM Priority which is used to do clock souce selection.
It only can be configured when SSM status is enabled"
::= { syncEPortEntry 4 }{'IF-MIB': ['InterfaceIndex', 'ifIndex', 'ifOperStatus'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['BridgeId', 'Timeout', 'dot1dStpPort', 'dot1dStpPortEntry'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'IpAddress', 'NOTIFICATION-TYPE', 'enterprises', 'TimeTicks'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'VlanIndex', 'VlanId', 'dot1qVlanStaticEntry'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'IEEE8021-PAE-MIB': ['dot1xAuthConfigEntry'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv6', 'InetAddressPrefixLength']}Related source files and packages:
Downloaded: 2026-10-23T19:26:18.242243+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.259.10.1.11.1.72.9.1.1 | syncEPortIndex | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.11.1.72.9.1.2 | syncEPortStatus | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.11.1.72.9.1.3 | syncEPortSSMStatus | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.11.1.72.9.1.5 | syncEPortTxQL | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.11.1.72.9.1.6 | syncEPortRxQL | 0 | 0 | |
| 1.3.6.1.4.1.259.10.1.11.1.72.9.1.7 | syncEPortForceClockSourceSelect | 0 | 0 |